Fan type F - EC Fan Corrosion protection E - Coil protection 0 - N/A Plenum P - With plenum N - N/A Filter D - Disposable N - N/A Control 1 - VLD 2 - Microset 0 - N/A CLIMA-FLEX...
To cope with this challenge Clima-Flex has developed a unit that provides comfort and energy savings at the same time, the variable Fan & Coil unit available in vertical and horizontal configuration.
The Variable F&C unit operates under the following principle: “It operates at the minimum capacity required to maintain the set conditions at all times and adjusts according to changes”. CLIMA-FLEX...
CLIFC VARIABLE - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Ubicación / Instalación Support structure Service clearance 500 mm Roof Return Air Suspension rod Unit Installation detail Sealing washer CLIMA-FLEX...
When refitting new filters into the equipment, it is important to ensure these are fitted correctly in respect of airflow. The correct orientation is obtained when the wire frame is positioned towards the heat exchanger, and the filter media completely covers the wire frame. CLIMA-FLEX...
Page 20
Any treated water within the coil fluid circulation system should not be drained into any waste water disposal system without Local Authority approval. It is the responsibility of the user and the maintenance personnel to ensure that all Local Authority and prevailing environmental legislation / guidelines are adhered to. CLIMA-FLEX...
Page 21
5. Position ETL / UL rated glue on the equipment casing, and press the new insulation into place. Let it cure and dry IMPORTANT: ETL / UL rated glue MUST be used for the unit to maintain its ETL rating. CLIMA-FLEX...
Page 22
Under normal operating conditions, the following schedule is recommended: Spares parts are available by contacting Clima-Flex main sales office. Enquiries should include details of the unit reference and contract number. which will be displayed on the identification label.
2. Press AND HOLD the middle square for five (5) seconds. The 1. Press SYSTEM, the text at the menu will change to display the 3. Press DONE to return to the bottom squares will clear. configuration variables. normal operation menu CLIMA-FLEX...
Page 24
100% to 0% operation is 100% to 0% NOTE NOTE of the motor power curve. of the motor power curve. Press DONE to return to the normal Press DONE to return to the normal operation menu. operation menu. CLIMA-FLEX...
Page 25
CLIFC VARIABLE - INSTALLATION, OPERATION AND MAINTENANCE MANUAL THIS PAGE INTENTIONALLY LEFT BLANK CLIMA-FLEX...
Page 26
CLIFC - Horizontal Variable Fan & Coil Av. Central No. 285, Parque Logístico Deleg. La Pila, San Luis Potosí, C.P. 78422 More info (444) 161.50.43 info@clima-flex.com Lada sin costo 01 800 890 59 17...
Need help?
Do you have a question about the CliFC Series and is the answer not in the manual?
Questions and answers