  • Page 1 BT100-1F PERISTALTIC PUMP OPERATING MANUAL Baoding Longer Precision Pump Co.,Ltd.
  • Page 2 BT100-1F OPERATING MANUAL IMPORTANT INFORMATION: Please read operation manual carefully before operation. WARNINGS: Tubing breakage may result in fluid being sprayed from pump. Use appropriate measures to protect operator and equipment. Please check the tubing frequently and change the tubing in time.
  • Page 3: Table Of Contents

    BT100-1F OPERATING MANUAL Table of Contents Instruction Operation Panel Basic Operation Running Inter face Flow Rate Display Dispensing Display Suitable Pump Head and Tubing Pump Head Installation Menu Diagram System Setting Pump Head and Tubing Setting External Control Address Footswitch Setting...
  • Page 4 BT100-1F OPERATING MANUAL Introduction Applicable pump heads for BT100-1F are YZ1515x, YZ2515x, YZII15, YZII25 and μ DG-1, DG-2, DG-4. The pump delivers flow rates from 0.16 L to 500 mL / min × and dispensing volume is from 0.01 mL to 9.99 L. Combining 128...
  • Page 5: Operation Panel

    BT100-1F OPERATING MANUAL Operation Panel LCD Display Knob Exit Key Direction Key Star t/Stop Key Prime Key Power Switch Basic Operation Start/Stop Key Press to star t or stop the pump Direction Key Press to change the rotation direction of the pump...
  • Page 6: Running Interface

    BT100-1F OPERATING MANUAL Running Interface Turn on the pump, the pump initializes itself first then display the running inter face. Flow Rate Display 7.000 mL/min 50.0 Dispensing Display: Dispensing status is displayed by two inter faces below, these inter face can be switched by pressing Exit Key 13.0 mL...
  • Page 7: Suitable Pump Head And Tubing

    BT100-1F OPERATING MANUAL Suitable Pump Heads and Tubing Suitable Pump Heads Tubing ( m m ) Ref. Flow Rate ( m L / m i n ) μ 7 L-7mL/min 0.027-27 0.051-51 0.082-82 0.17-170 Ⅱ 0.29-290 YZ1515 YZ 15 0.38-380 0.17-170...
  • Page 8: Pump Head Installation

    BT100-1F OPERATING MANUAL Pump Head Installation The pump head is mounted on drive before the pump leaves the factory. Follow below procedure for changing another pump head. Loose the two M4 screws which connect the pump head and the drive.
  • Page 9: System Setting

    When control computer controls many pumps through RS485 inter face, it must identify each pump's I. D. This pump I.D. should be unique. It's the identification of this pump. Maximum 30 pieces BT100-1F can be controlled through RS485 at the same time.
  • Page 10: Footswitch Setting

    BT100-1F OPERATING MANUAL Footswitch Setting Footswitch has two kinds of working status. Trigger: Press footswitch, the pump star ts running; Press footswitch again, the pump stops. Gated: The pump runs as long as the footswitch is pressed. Set Footswitch Press and turn Knob to highlight the Footswitch line.
  • Page 11: Control Mode

    BT100-1F OPERATING MANUAL Control Mode The pump has two kinds of working mode: Flowrate Dispensing Control Mode: Press and turn the knob to highlight control mode line. Press Knob to enter next inter face, turn Knob to select control mode, press...
  • Page 12: Flowrate

    BT100-1F OPERATING MANUAL Flow Rate: Adjusting the dispensing flow rate can change the dispensing time. Press and turn Knob to highlight dispensing flow rate line. Press Knob to enter next inter face, turn Knob to select suitable flow rate. Press...
  • Page 13: Dispensing Volume Calibration 1

    BT100-1F OPERATING MANUAL If the actual volume is known in advance, enter the calibration inter face and input the actual volume directly. : : : Flowrate Test T. 0.5 ’ Test T. 0.5 ’ Act Vol : μ : μ...
  • Page 14: Operation Procedure 1

    BT100-1F OPERATING MANUAL Operation Procedure Select pump head and tubing refer to “Suitable Pump head, Tubing, Ref. Flow Rate” table before working. Thick wall tubing is preferred for longer ser vice life. Flow rate mode operation procedure Press Knob Confirm the flow...
  • Page 15: External Control Input 1

    BT100-1F OPERATING MANUAL External Control Input Communication Control RS485 External Control DB15 4 - 20 mA Speed Control 0 - 5 V Speed Control Analog Control 0 - 10 V Speed Control 0 10 KHz Speed Control Communication Control The pump can connect to control computer (computer, PLC, SCM) through RS485 serial communication module (shown as below).
  • Page 16 BT100-1F OPERATING MANUAL Terminals Definition Analog input in 4 20 mA, 0 - 5 V, 0 10 V external control module Terminal 1 to control the speed of pump. External control star t/stop input. Open, the pump runs; Close, the Terminal 2 pump stops.
  • Page 17: External Control Output 1

    BT100-1F OPERATING MANUAL External Control Output Pump is equipped with output por t in order to monitor the status of pump. It adopts DB9 male socket as output por t (see as below). External control output star t/stop output, CW/CCCW output and pulse output ( 0 - 100 rpm corresponding to 0 - 10 kHz).
  • Page 18: Communication Function 1

    BT100-1F OPERATING MANUAL Communication Function BT100-1F can connect to the control computer (computer, PLC, SCM) through RS485 serial communication inter face. Max. 30 pumps can be controlled by a control computer. Note: 1. The pump ID which connects to the control computer through RS485 serial communication inter face must be unique to prevent the communication error.
  • Page 19: Technical Specification 1

    BT100-1F OPERATING MANUAL Technical Specifications Functions Acceptable Pump Head: YZ1515X, YZ2515X, YZII15, YZII25, DG-1, DG-2, DG-4 Operation Mode: Membrane keypad and Knob Direction Control: CW and CCW, reversible Prime: Full speed for fast filling and emptying Back Suction: Preventing drippage of the liquid...
  • Page 20 Baoding Longer Precision Pump Co.,Ltd ADD: Building A,Chuangye Center Baoding National High - Tech Industrial Development Zone Baoding,Hebei,China 071051 TEL: 86 - 312 - 3110087 3138553 FAX: 86 - 312 - 3168553 E - mail: longer@longerpump.com Www.longerpump.com...