Dover Petro Vend M1040-ANT Installation Manual
Dover Petro Vend M1040-ANT Installation Manual

Dover Petro Vend M1040-ANT Installation Manual

Automatic vehicle identification antenna

Advertisement

Quick Links

Installation Manual
[Part Number: - M1040-ANT
[Revision: - 0
Automatic Vehicle Identification Antenna

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Petro Vend M1040-ANT and is the answer not in the manual?

Questions and answers

Summary of Contents for Dover Petro Vend M1040-ANT

  • Page 1 Installation Manual [Part Number: - M1040-ANT [Revision: - 0 Automatic Vehicle Identification Antenna...
  • Page 2 OPW Fuel Management Systems is a part of Dover Fueling Solutions. Copyright Information © 2021 Dover Fueling Solutions. All rights reserved. DOVER, the DOVER D Design, DOVER FUELING SOLUTIONS, and other trademarks referenced herein are trademarks of Delaware Capital Formation.
  • Page 3: Table Of Contents

    3.2.2 Assemble the Antenna and Bracket 3.2.3 Cable Routing 3.2.3.1 Cable Routing Outside the Pole 3.2.3.2 Cable Routing Inside the Pole 3.3 Complete the Installation 3.3.1 Panel Antenna Installation Scenario - Terminal VIS Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 4 3.3.2 Panel Antenna Canopy Installation Scenario - Terminal VIS 3.4 Remote Installation 3.4.1 Panel Antenna Installation Scenario - Remote VIS Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 5: Section 1 Important Safety Information

    A fuel dispenser is a hazardous area as specified in the National Electrical Code. Installation must with the codes that follow: National Electrical Code (NFPA No. 70) Motor Fuel Dispensing Facilities and Repair Garages Code (NFPA No. 30A) Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 6: Nfpa/Nec - Class I, Div. 1 & Div

    (PPE). This includes safety glasses, hardhat, safety shoes and reflective vest. Barricade the work area before installation. Be sure to obey all applicable Lockout/Tagout (LOTO) procedures before installation. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 7 IMPORTANT: It is recommended to do a check of the electrical system with a multimeter to make sure all connections are de-energized before you proceed with the installation. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 8: Section 2 Omni Antenna

    2.1 Components The Omni Antenna kit (OPW-FMS P/N 20-4502-1) has these components: Antenna base, stem, assembly tool and 12' cable(OPW-FMS P/N 75-3067) Bracket (OPW-FMS P/N 51-0589) Cable Gland (OPW-FMS-P/N 50-0567) Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 9: Terminal Installation

    Make sure the antenna is isolated from the pole. Use a non-conductive material between the antenna bracket and the metal pole. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 10: Assemble And Install The Antenna

    1. Put the antenna stem over the threaded post of the base and turn clockwise to tighten. Be sure that the stem is flush with the bottom of the post. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 11 2. Put the right-angle connector of the cable through the center hole of the long part of the bracket. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 12 3. Assemble the antenna to the connector as shown above. Use the plastic assembly tool that was included in the kit to tighten the antenna to the connector. 4. Install the clamps through the cut outs in the bracket as shown above. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 13 6. Install the pole into the flange. Turn the pole clockwise until the pole is almost to the end of the threads and the antenna points in the correct direction. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 14: Cable Routing

    2.2.3.1 Cable Routing Outside the Pole As an alternative the cable routing can go outside the pole. Use cable ties at regular intervals to attach the cable to the outside of the pole. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 15: Cable Routing Inside The Pole

    2. Connect the SMA connector to the Antenna Connector of the AVI board in the terminal. 3. Connect the 20-1732 terminal connections to the J1 Terminal Block of the VIS board. Connect the 4- Pin Molex connector to an open Power Supply connector. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 16: Omni Antenna Installation Scenario - Terminal Vis

    2.4.1 Omni Antenna Installation Scenario - Remote VIS For maximum antenna range, install the antenna a minimum of 12 feet from ground level. The remote VIS enclosure should be installed at eye level. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 17: Section 3 Panel Antenna

    NOTE: A threaded flange and pole are recommended. NOTE: If the pole needs additional support it can be clamped to a nearby support or structure. DO NOT clamp to pole to the pedestal or terminal. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 18: Install The Flange

    Install the flange so the pole will be close to the left side of the pedestal. Use the correct bit and fasteners for the material where the flange is installed. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 19: Assemble The Antenna And Bracket

    2. Assemble the Pole/Wall Mount (MNT-22-3) to the Angle Bracket (MNT-22-2). Align the two parts so that their toothed surfaces point to each other and the holes are aligned. Put a Flat Washer and Lock Washer over the holes. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 20 Start with the angle at aproximately 45°. Adjust the angle so that the line of sight from the center of the antenna "looks" to the farthest RFN in the antenna's range (to a maximum of 130 feet). 5. Attach the antenna connector. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 21: Cable Routing

    Make sure the rubber seal is under the top nut and is tight enough to keep moisture out of the terminal enclosure. 3.2.3 Cable Routing The Antenna Cable attached to the outside of the pole or can be put through the inside of the pole. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 22: Cable Routing Outside The Pole

    3.2.3.1 Cable Routing Outside the Pole As an alternative the cable routing can go outside the pole. Use cable ties at regular intervals to attach the cable to the outside of the pole. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 23: Cable Routing Inside The Pole

    2. Connect the SMA connector to the Antenna Connector of the AVI board in the terminal. 3. Connect the 20-1732 terminal connections to the J1 Terminal Block of the VIS board. Connect the 4- Pin Molex connector to an open Power Supply connector. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 24: Panel Antenna Installation Scenario - Terminal Vis

    3.3.2 Panel Antenna Canopy Installation Scenario - Terminal VIS The Panel Antenna can be installed under a canopy. The cable can beinstalled to a terminal installed VIS or a Remote VIS enclosure. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 25 For maximum antenna range, install the antenna at approximately a 45 degree angle and a minimum of 12 feet from ground level. The remote VIS enclosure should be installed at eye level. A sealed conduit for the antenna cable is reccomended to protect the cable. Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...
  • Page 26 Revisions M1040-ANT Revision # Effective Software Version Key Changes 1966 10/15/2021 Initial Release NOTE: It is possible that older software versions might not support all features Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions...

Table of Contents