24- -V Wiring; Accessories - Bryant 830CA Installation, Start--Up, Operating, And Service And Maintenance

4-way multipoise ultra low nox communicating, 80% afue gas furnace
Table of Contents

Advertisement

Fig. 22 - - Field- -Supplied Electrical Box on Furnace Casing

24- -V WIRING

Make field 24- -v connections at the 24- -v terminal strip. (See Fig. 24)
Connect terminal Y as shown in Fig. 45 for proper cooling
operation. Use only AWG No. 18, color- -coded, copper thermostat
wire.
The 24- -v circuit contains an automotive- -type, 3- -amp. fuse located
on the control. Any direct shorts during installation, service, or
maintenance could cause this fuse to blow. If fuse replacement is
required, use ONLY a 3- -amp. fuse of identical size.

ACCESSORIES

1. Electronic Air Cleaner (EAC)
Connect an accessory Electronic Air Cleaner (if used) us-
ing 1/4- -in female quick connect terminals to the two male
1/4- -in quick- -connect terminals on the control board
marked EAC- -1 and EAC- -2. The terminals are rated for
115VAC, 1.0 amps maximum and are energized during
blower motor operation. (See Fig. 23)
2. Humidifier (HUM)
The HUM terminal is a 24 VAC output, energized when
the blower is operating during a call for heat.
Connect an accessory 24 VAC, 0.5 amp. maximum hu-
midifier (if used) to the 1/4- -in male quick- -connect HUM
terminal and COM- -24V screw terminal on the control
board thermostat strip. (See Fig. 23)
NOTE: DO NOT connect furnace control HUM terminal to
HUM (humidifier) terminal on Thermidistatt, Zone Controller
or similar device. See Thermidistat, Zone Controller, thermostat,
or controller manufacturer's instructions for proper connection.