Inficon IC1000 Translation Of The Original Operating Instructions
Inficon IC1000 Translation Of The Original Operating Instructions

Inficon IC1000 Translation Of The Original Operating Instructions

Interface adapter

Advertisement

Quick Links

Translation of the Original Operating Instructions
IC1000
Interface adapter
Catalog No.
525-200
From software version
V1.11
jiqn22en1-01-(2205)

Advertisement

Table of Contents
loading

Summary of Contents for Inficon IC1000

  • Page 1 Translation of the Original Operating Instructions IC1000 Interface adapter Catalog No. 525-200 From software version V1.11 jiqn22en1-01-(2205)
  • Page 2 INFICON GmbH Bonner Strasse 498 50968 Cologne, Germany...
  • Page 3: Table Of Contents

    5 Installation and removal .......................... 14 5.1 Mount IC1000 and DIN-TS35 top-hat rail.................... 14 5.2 Establish connections .......................... 14 5.3 Remove the IC1000 from the DIN-TS35 top hat rail ................ 16 6 Decommissioning ............................ 17 6.1 Disposing of the device ..........................  17 6.2 Returning the device for maintenance, repair or disposal..............
  • Page 4: About This Manual

    This instruction manual is intended for operators and technically qualified personnel with experience in leak detection technology and the integration of leak detectors in leak detection systems. In addition, the installation and use of the device require knowledge of electronic interfaces. 4 / 24 IC1000-Operating-Instructions-jiqn22en1-01-(2205)
  • Page 5: Dangers

    • Connecting a non-compatible device to the LD interface • Assignment of the actually unused RS485 terminals • Use in radioactive areas • Operation under unsuitable ambient conditions • Use outside the technical specifications. • Use of wrong cables and wires IC1000-Operating-Instructions-jiqn22en1-01-(2205) 5 / 24...
  • Page 6: Safety

    INFICON 2 Safety 2.1 Intended use The IC1000 is an interface adapter between a leak detector and a BM1000. ► Operate the device only according to this instruction manual. 2.2 Duties of the operator • Read, observe, and follow the information in this manual and in the work instructions provided by the owner.
  • Page 7 • Only instructed personnel should be permitted to work with and on the device. The instructed personnel must have received training on the device. • Make sure that authorized personnel have read and understood the instruction manual and all other applicable documents, see “Other associated documents [} 4]“. IC1000-Operating-Instructions-jiqn22en1-01-(2205) 7 / 24...
  • Page 8: Scope Of Delivery, Transport, Storage

    INFICON 3 Scope of delivery, transport, storage Scope of delivery Item Quantity IC1000 Data cable Set of cables Operating manual ► Check the scope of delivery after receipt of the product to make sure it is complete and to check for external damage.
  • Page 9: Description

    Power supply 24 V DC Serial cable Data cable Fieldbus cable The IC1000 is an interface between a leak detector and a BM1000. It allows the BM1000 to be used on a leak detector without LD interface (M12 connector). IC1000-Operating-Instructions-jiqn22en1-01-(2205)
  • Page 10: Structure Of The Ic1000

    A prerequisite is that the leak detector has an RS232 interface that can handle the LD protocol with 19200 or 38400 baud. For this purpose, the IC1000 has an RS-232 port for connection to the leak detector and an LD interface for connection to the BM1000. this only applies to the ECOTEC E3000 from software version V3.33.
  • Page 11 Also two DIP switch blocks (S1 and S2). The baud rate for the LD protocol on the RS232 interface can be selected via DIP switch S2 / 1 on the IC1000. The IC1000 supports 19200 or 38400 baud (8 data bits, no parity, 1 stop bit, no hardware flow control).
  • Page 12 4 | Description INFICON 24V IN 24 V input Pin assignment: Name + 24V The voltage supply is normally provided by the leak detector. Use the appropriate cable from the supplied cable set for this purpose. 12 / 24 IC1000-Operating-Instructions-jiqn22en1-01-(2205)
  • Page 13: Technical Data

    The housing of the device is composed of synthetic material. Switch off the device and disconnect from the mains. When cleaning the housing, use an agent accepted for synthetic surfaces (for example a light household cleaner). Do not use any solvents that attack synthetic materials. IC1000-Operating-Instructions-jiqn22en1-01-(2205) 13 / 24...
  • Page 14: Installation And Removal

    Connect the RS232 and 24V IN ports to the leak detector using the cables supplied in cable set 200010785. If for some reason you want to operate the IC1000 with a separate 24 V supply voltage, observe the following note: NOTICE The device must be supplied with a circuit that meets the requirements of "Energy-...
  • Page 15 INFICON Installation and removal | 5 Connect IC1000 with BM1000 Use the data cable to connect the LD connector on the IC1000 to the LD connector on the BM1000. Length (in meters) Catalog number 560-334 560-332 560-335 560-340 Table 1: Data cable NOTICE The data cables cannot be connected in series.
  • Page 16: Remove The Ic1000 From The Din-Ts35 Top Hat Rail

    5 | Installation and removal INFICON 5.3 Remove the IC1000 from the DIN-TS35 top hat rail Fig. 3: Remove IC1000 1. Use the flat-tip screwdriver to pull out the locking device. 2. Pull the device off of the top hat rail.
  • Page 17: Decommissioning

    ð You will then receive a return number and the shipping address. Use the original packaging when returning. Before shipping the instrument, attach a copy of the completed contamination declaration to the outside of the package. IC1000-Operating-Instructions-jiqn22en1-01-(2205) 17 / 24...
  • Page 18 6 | Decommissioning INFICON 18 / 24 IC1000-Operating-Instructions-jiqn22en1-01-(2205)
  • Page 19: Appendix

    Length (in meters) Catalog number 560-334 560-332 560-335 560-340 Table 2: Data cable NOTICE The data cables cannot be connected in series. The voltage supply is normally provided by the leak detector. The length must not exceed 30 meters. IC1000-Operating-Instructions-jiqn22en1-01-(2205) 19 / 24...
  • Page 20: Ce Declaration Of Conformity

    7 | Appendix INFICON 7.2 CE Declaration of Conformity 20 / 24 IC1000-Operating-Instructions-jiqn22en1-01-(2205)
  • Page 21 INFICON Appendix | 7 IC1000-Operating-Instructions-jiqn22en1-01-(2205) 21 / 24...
  • Page 22: Rohs

    7 | Appendix INFICON 7.3 RoHS 22 / 24 IC1000-Operating-Instructions-jiqn22en1-01-(2205)

This manual is also suitable for:

525-200

Table of Contents