Anigmo AE-2400RM Manual

Anigmo AE-2400RM Manual

Touchless switch

Advertisement

Touchless switch
Touchless switch with 10A relay output
Models: AE-2400 R, AE-2400RM, AE-S
Important notes
CAUTION:
Read and understand these instructions before
1.
installing the device. Before installing this unit,
disconnect power at the circuit breaker or remove
fuse to avoid shock or damage to the unit. This
device is intended for installation with local
regulations. It is recommended that a qualified
electrician perform this operation
2.
Do not install in combination with standard 3-Way
switches or third-party remote (slave) unit.
Use only in combination with Anigmo AE-S
remote (slave)unit.
Installation of this switch in the proximity of strong
3.
EM interference such as (and not limited to)
electrical welding machines, inadequately shielded
power supplies, radars, etc. could cause inadvertent
switch activity.
This switch may not be used in any application in
4.
which the inadvertently changing the switch state
could create a situation where personal injury, death
or property damage may occur.
This unit requires a neutral connection
5.
6.
Do not exceed the maximal rated current of the unit
Warranty
All products sold or distributed by Anigmo or any of
its subsidiaries are guaranteed to be free from defects
in materials and workmanship for the period of 5 years.
This warranty shall extend to the original end
purchaser only. Anigmo, at its option, shall repair or
replace any Anigmo product within the Terms of
Warranty expressed herein, which fails to meet the
product's specifications.
This warranty does not extend to product failures or
defects caused by, or associated with, but not limited
to; failure to install or maintain correctly, unsuitable
physical or operating environment, accident, force
majeure, hazard, misuse, electrical supply,
unauthorised repair, modification or alteration.
Anigmo will not accept any liability or responsibility
under the terms of warranty expressed herein for,
but not limited to; negligence, loss of profit or data or
damages either material or personal. Mandatory
liability shall be restricted to the sum equal to the
purchase of the product.
This product may be protected by following patents
US 7.531.921, EP 2.038.906, US20090284182,
US 8.339.062, EP 2.292.078
Contact
ANIGMO
Anigmoteh d.o.o.
Tehnoloski park 21
1000 Ljubjana
Slovenia, Europe
www.anigmo.com
email: support@anigmo.com

INSTALLATION

1. WARNING: Turn power OFF at circuit breaker
or remove the fuse
2. Connect wires as shown. Refer to wiring
diagrams.
LOAD
HOT
NEUTRAL
3. Before installing the unit into a wall box, set the
desired sensor range if needed.
NOTE: The unit is supplied with its sensing range
set to maximum ( about 10 cm).

WIRING DIAGRAM

SINGLE LOCATION CONTROL (one switch controlling one load)
F *
L
N
S
N
L
AE-2400 R
wallbox
MULTI LOCATION CONTROL (multiple switches controlling one load)
*
F
L
N
S
N
L
AE-2400 R
wallbox
4. Mount the unit into wall box using claws.
Align before tightening the claw screws
If mounting with screws, first remove both claws,
complete with nuts and screws. Fix the unit
with provided screws only.
5. Attach decorative switchplate. Align magnets on the
back of the switchplate with magnets on the unit
and push.
6. Restore power at the circuit breaker
Load rating:
240V AC / 50Hz
10A max
LOAD
* Connect only to mains
protected with
fuse rated 10A or less.
LOAD
S
L
AE-S
wallbox
S
L
AE-S
wallbox

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AE-2400RM and is the answer not in the manual?

Questions and answers

Summary of Contents for Anigmo AE-2400RM

  • Page 1 Do not exceed the maximal rated current of the unit Warranty All products sold or distributed by Anigmo or any of its subsidiaries are guaranteed to be free from defects in materials and workmanship for the period of 5 years.
  • Page 2 AE-2400R TOUCHLESS SWITCH OPERATIONAL MANUAL AE-2400R can switch various loads, including Incandescent, Halogen, Low voltage Halogen, LED, CFL, and linear fluorescent lamps. When AE-2400R is connected and powered up, the lights can be turned on by moving the hand in front of the switch plate. When the hand enters the switch sensing range, the lights will turn on. The hand should then move out of the sensor range.

This manual is also suitable for:

Ae-2400 rAe-s

Table of Contents