Fig. 18: Filter Plug View; Table 12: Volume Of Water Per Cleaning Process; Table 13: Tightening Torques (81125) - ABB XAC18723 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
6 Periodic maintenance / 6.4 Cleaning the compressor during opera-
tion
Repeating the cleaning
If the cleaning is still unsuccessful after three processes, it is recommended to have the tur-
bocharger checked and cleaned by an ABB Turbocharging Service Station if the engine val-
ues are unsatisfactory.
Volume of water per cleaning process
Product
A165-L
A170-L
A175-L
A180-L
A185-L
A190-L
Table 12: Volume of water per cleaning process
The filling time is 4 ... 15 seconds.
Checking the filter plug
The filter plug only needs to be checked in the turbocharger version with a cast filter silen-
cer. See chapter
Design variants
Fig. 18: Filter plug view
Disassembly and checking of the filter plug (81125) is required if, 20 seconds after the clean-
ing process, water is still visible in filler opening B.
Loosen and remove the filter plug (81125) with box spanner
u
Clean the drill holes of the plug
u
Fit filter plug (81125).
u
Part number
A165-L
81125
G1/2"
45 Nm
Table 13: Tightening torques (81125)
© Copyright 2018 ABB. All rights reserved.
→58.
A170-L
A175-L
G1/2"
G1/2"
45 Nm
45 Nm
HZTL4034_EN
3
Quantity [dm
]
2.0
2.0
3.0
3.0
3.0
3.0
A180-L
A185-L
G1/2"
G1/2"
45 Nm
45 Nm
Revision M
A190-L
G1/2"
45 Nm
August 2018