Operation Manual / 4 Product description / A130-M.. - A145-M..
3 Commissioning / 3.2 Inspection procedures
Version with water-cooled bearing casing
CAUTION
Failure of bearing casing cooling
Any prolonged failure of the water cooling will shorten the lifetime of the
turbocharger.
Make sure that an uninterrupted supply of cooling water is provided dur-
u
ing operation.
Check whether the water pipes are fitted on the bearing casing.
u
3.2.3
Checks after commissioning (engine in idle mode)
Lubricating system
Keep to the lubricating oil pressure at the inlet.
u
Keep to the lubricating oil temperature at the inlet.
u
Refer to chapter
Monitoring operation →27
u
Leaktightness of pipes
WARNING
Risk of burning from hot gas
Escaping gases are hot and will lead to serious burns in the event of contact.
Check all pipes for leaks in accordance with the enginebuilder's instruc-
u
tions.
3.2.4
Checks when starting up the engine
If present:
Measure speed, oil pressure and charging pressure at various engine performances.
u
Measure the exhaust gas temperature before and after the turbine.
u
Measure the air temperature before and after the compressor.
u
Compare the measured values with the values of the acceptance report. Different operat-
u
ing conditions indicate a malfunction (see chapter
Lubricants and pastes used during assembly can liquefy or vaporise and escape as oily fluids
during the initial hours of operation. Continual escape of an oily fluid indicates an oil leak. If
there is a leak, contact an ABB Turbocharging Service Station.
© Copyright 2018 ABB. All rights reserved.
for admissible values.
Eliminating malfunctions
HZTL4031_EN
→60).
Revision G
October 2018