Table of Contents INTRODUCTION ..........................4 SPECIFICATIONS ............ERROR! BOOKMARK NOT DEFINED. III. WARRANTY INFORMATION ...................... 4 SAFETY ............................5 ........................... 5 AFETY ARNINGS .......................... 5 AFETY QUIPMENT QUICK START GUIDE ........................6 ..........................6 NCRATE .......................... 6 NSTALL IGHT ........................
Page 3
FOREWORD 1. This manual describes the procedures required to operate the Clarus PCS-35 AGITATING SOLVENT PARTS CLEANING STATION. Every effort has been made by Clarus Technologies, LLC to assure the accuracy and reliability of the information contained in this document. Clarus Technologies, LLC, however, makes...
This Limited Lifetime Parts Warranty is limited to the following components: Main chassis Clarus Technologies, LLC, will for the period of 1 year from the date of purchase, repair or replace without charge, the items listed below which our examination proves to be...
tampered with by unauthorized persons, misused, abused, or improperly installed and has been used in accordance with the instructions and/or ratings supplied. This 1 year Mechanical/Electrical Component Warranty covers the following components: Electrical control systems Pneumatic system Main pump NOTE: Consumable items such as light bulbs, O-Rings and filters are excluded from any such warranty.
Different types of gloves may be required for differently types of fluids. The local safety supply source can recommend the appropriate protective gloves. 3. Flammable. For the safety of owners and operators NO SMOKING around or near this equipment. QUICK START GUIDE Please read entire Quick Start Guide before beginning, this will avoid possible start up problems.
3. When unit automatically shuts off (approximately 4 minutes) check fluid level and fill to full line. Congratulations – your unit is ready! PARTS DESCRIPTION & OPERATION On-Button. To turn the Parts Washer on, simply depress the green “ON” switch once. This will turn the system on for a 4-minute cycle.
The PCS-25 and PCS-15 come with an optional stainless steel soak tank (“Soak Tank”) and a UL approved submersible agitation pump. The “on/off” switch for the Soak Tank is located on the lower left hand corner of the lid. Prior to turning the agitation tank on: 1) Place the stainless steel tank along the left hand side wall of the working surface, 2) Turn the PCS-25/PCS-15 on by depressing the green “on”...
right side of the unit, remove the cap and put it either in a bucket or barrel and turn the hose end valve on. Second, open the yellow valve handle on the main shelf. Third, move the handle back and forth on the sump pump located on the shelf. Pump the sump out till the solvent changes color.
Page 10
Part No. Item Solvent 1156-5 Solvent - 5 gallon Type II-A 1156-15 Solvent - 15 gallon Type II-A 1156-55 Solvent - 55 gallon Type II-A 250-SS-5 Solvent - 5 gallon Type V 250-55 Solvent - 55 gallon Type V 1157-5 Solvent - 5 gallon Type II-B 1157-55 Solvent - 55 gallon Type II-B...
Light doesn’t work: 1. Check power cord, is it plugged into electrical box plug labeled “light bar”? 2. Replace light bulb, 150-watt halogen. 3. Confirm parts washer is plugged into wall outlet. Fusible Link doesn’t line-up with tab on lid: 1.
Pump running but not pumping fluid: 1. Remove fluid from tank, remove intake and discharge hose from pump. Use compressed air to clear hoses. 2. Remove front cap on pump and check for debris or wear. Replace if necessary. Main Pump leaking: 1.
Need help?
Do you have a question about the PCS-35 and is the answer not in the manual?
Questions and answers