1.0 I 7.0 F NTRODUCTION LASH EPLACEMENT The Check•Line ® DT-721(AC-powered) and DT725 (battery powered) Digital When FPM reading is displayed but unit is not flashing, the flash tube may need Stroboscopes are highly stable, industrial-quality instruments for non-contact to be replaced.The procedure is as follows: RPM measurement as well as for inspecting and observing moving parts 1.
Page 4
5.0 M 3.0 B (DT-725 EMORY ATTERY USAGE ONLY When the strobe is turned off and on again at a later time, it will start to flash at Model DT-725 is equipped with an internal, lead acid, rechargeable battery that the previous displayed rate regardless if the setter has been moved or not.
4.3 Synchronous Output Signal 4.0 O PERATION The Synchronous output signal appears on the tip of the output phone jack. 4.1 Internal Triggering See below 1. DT-721 only: Firmly plug the power cord into a 100 VAC (Japan), 120 VAC (US) or 230 VAC (Europe) power source. DT-725 only: Charge battery for approx.
Page 6
9.0 W ARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect in workmanship or material in the product existing at the time of delivery thereof which manifests itself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at ELECTROMATIC’s option, except where unauthorized repair,...