2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562) 986-9105, FAX (562) 986-9205
SR-10A Stand-Alone Access Control System
The SR-10A is designed to read a specified number of digits from a magnetic stripe card
and can accept up to 100 combinations of those digits.
Setup
Step 1: Decide How Many Digits to Read
The first step is to tell the reader how many digits to read
from the card. This is done by using J2 jumpers 1-3. Using
the table on the right, set J2 jumpers 1-3 to the appropriate
setting. Remove J2 jumpers 1 through 3 for "ATM" mode,
grants access to any card with data on track 2.
Step 2: Set Door Strike Timing
There are two door strike durations that are selectable by J2
jumper 4. When the J2 jumper 4 is "IN", the strike duration
is 5 seconds. When J2 jumper 4 is "OUT", then the duration
is 1 second.
Now the reader is ready to accept card information.
Card Maintenance
Enrolling New Card(s) to the System
To enroll a new card into the SR-10A, perform the following steps:
1. Remove J2 jumper 6. Once removed, the LED on the reader flashes green.
2. Swipe each card to be enrolled, the reader will beep two times for each good card read.
3. Reinstall J2 jumper 6 after enrolling card(s). The LED on the reader will turn red and the reader will beep three
times.
The reader is now ready to be used.
Deleting the Card Database
To delete the cardholder database, perform the following steps:
1. Remove power from the unit and install J2 jumper 8.
2. Apply power for 5 seconds, LEDs A and B ON, and then remove power.
3. Remove J2 jumper 8 and reconnect power.
The card database is now empty. You must then re-enroll your cards.
Note: In the ATM mode, enrolling and deleting cards is not required.
TB3
NC
C
NO
NO
NC
C
VIN
GND
I2
I2
I1
I1
TB2
CONFIDENTIAL: For installation and maintenance use only. DO NOT distribute.
Mercury Security Corporation,
Strike
Forced Open,
Held Open
Alarm Buzzer
Exit Request
Door Contact
©
2008
SR-10A
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.
J2 Jum pe r #
1-3
4
5
6
7
8
Jumper 1
OUT
IN
OUT
IN
OUT
IN
OUT
IN
.2 [5.08]
GND (BLK)
BZR (ORG)
LED (BRN)
CLK (WHT)
DAT (GRN)
12V (RED)
PIN 1
J2 JUMPERS
J2
Ø.156 [Ø 3.96]
Doc. 10107-0017 rev. 1.02 10/2008
www.mercury-security.com
De scription
Select Number of Digits
to Read on Card
Strike Relay Duration
Not Used
Enroll Cards
Not Used
Delete All Cards
Jumper 2
Jumper 3
# of Digits
OUT
OUT
OUT
OUT
IN
OUT
IN
OUT
OUT
IN
OUT
IN
IN
IN
IN
IN
4.25 [108.0]
3.85 [97.8]
TB3
K1
TB4
GND
BZR
LED
K2
DAT
D1
DAT
D0
J6
VO
TR+
TR-
GND
TB1
J4
1 2 3 4 5 6 7 8
B A
TB2
J3
Page 1
0
1
2
3
4
5
6
7
.2 [5.08]
NC
C
NO
NO
NC
C
VIN
GND
I2
I2
I1
I1
Need help?
Do you have a question about the SR-10A and is the answer not in the manual?
Questions and answers