Signal input flowmeter: RS485 Modbus master interface
Options: RS232 FTL Communication for Truck On Board Computer
C-Series - Indicators and Controllers for custody transfer in hazardous areas.
C401
DISPENSER
RS232 Ticket Printer Communication (ASCII)
FW-C401-M_v0105_01_EN.docx
More info: www.fluidwell.com/cseries.

Advertisement

Table of Contents
loading

Summary of Contents for Fluidwell C401

  • Page 1 Page 1 C401 DISPENSER Signal input flowmeter: RS485 Modbus master interface Options: RS232 FTL Communication for Truck On Board Computer RS232 Ticket Printer Communication (ASCII) C-Series - Indicators and Controllers for custody transfer in hazardous areas. FW-C401-M_v0105_01_EN.docx More info: www.fluidwell.com/cseries.
  • Page 2: Safety Instructions

    The C401 must be installed in accordance with the EMC guidelines (Electro Magnetic Compatibility). • Do connect a proper grounding to the housing as indicated if the C401 is used on a ship, truck or other application with no physical earth. DISPOSAL OF ELECTRONIC WASTE •...
  • Page 3: About The Operation Manual

    This operation manual describes the standard C401 as well as most of the options available. For additional information, please contact your supplier. A hazardous situation may occur if the C401 is not used for the purpose it was designed for or is used incorrectly. Please carefully note the information in this operating manual indicated by the pictograms: A "warning !"...
  • Page 4: Table Of Contents

    SAFETY RULES AND PRECAUTIONARY MEASURES ..................2 ABOUT THE OPERATION MANUAL........................3 CONTENTS MANUAL ............................4 INTRODUCTION ............................. 5 System description of the C401 ....................5 OPERATIONAL ............................6 General information ......................... 6 Operator information and functions ..................6 Control panel ..........................7 Making deliveries ........................
  • Page 5: Introduction

    SYSTEM DESCRIPTION OF THE C401 Functions and features The C401 Dispenser is designed to be mounted inside a cabinet on a trailer to perform deliveries of Hydrogen or other gasses in combination with a Rheonik Coriolis flowmeter with RHE28 or similar transmitter.
  • Page 6: Operational

    ▲ or ▼key causes the display to switch from volume to mass, and vice-versa. OPERATOR INFORMATION AND FUNCTIONS When the C401 Dispenser is at Operator level and ready to perform a new task, one of the following delivery screens is shown, depending on the configuration of the volume calculation functions: At the top of the screen a status bar is displayed.
  • Page 7: Control Panel

    E.g. ‘Drücke CLEAR zum Fortfahren’. CONTROL PANEL The following keys are available: Fig. 2: Control panel The functions of the keys at operator level, depend on the actual status of the C401: Functions of the keys in BEREIT status...
  • Page 8 A summary of the delivery is shown and the operator has the possibility to perform the following actions: STOP / CLEAR key This key is used to close the current dispense operation and return the C401 BEREIT status.. ▲ or ▼ key...
  • Page 9: Making Deliveries

    If the Zeroing operation was not successful (e.g. when the flowrate was not set to zero), an error will be displayed. The C401 waits for the flowmeter to finish the Zeroing process. If this fails, a 2 minute timeout on the Zeroing process guarantees that the Zeroing process will always finish.
  • Page 10 (0). This is also the moment at which the operator must close the manual valve within 5 minutes. KOMPLETT When the flow rate has reached zero (0), the C401 will enter the status: the delivery is completed and a delivery summary is shown indicating the delivered quantity, the duration of the delivery and the unique delivery number (Lieferungsnummer).
  • Page 11: Forced Stop

    Page 11 FORCED STOP If, for some reason, it is not possible to return the flow rate to zero (0), the C401 will wait 5 minutes before signalling a warning: At this point, if the operator is able to stop the flow, the delivery will be finished without any error.
  • Page 12 / opened. During the delivery, the service mode Servicemodus Service mode Mode service was active / activated. During the delivery, the door of the C401 Türschalter Door switch Contact de porte was open / opened. The clock was set in user-mode and not...
  • Page 13: Delivery Record

    Flowmeter tube temperature at start of Start start début delivery Tube Temp. Tube temp. Tube temp. Flowmeter tube temperature at end of Ende delivery * : Density, reference pressure, reference temperature and volumetric delivered quantity are only indicated when volume conversion is enabled. FW-C401-M_v0105_01_EN.docx...
  • Page 14 The metrology lock was disabled at the beginning or during the delivery. 0x0100 The door of the C401 was open at the beginning or during the delivery. 0x0200 This bit indicates that at the end of the delivery, communication with the Flowmeter was restored and is only valid if the connection lost error (0x020) is also set.
  • Page 15: Configuration And Information

    To confirm the new value, press the key again. To dismiss the changes, press STOP / CLEAR key. MENU- AND SETUP-LEVEL The following table shows the build-up of the menu inside the C401 and the settings available at SETUP-level. Access MENU Entry Description and available settings...
  • Page 16 1 startbit, 1 stopbit, RTU, address 1) Installer Note: Bold marked symbols represent default values. Access Level indicates the minimum level required to change the parameter. See paragraph 5.2.3: Access Level / Zugangsstufe for more information on Access Levels. FW-C401-M_v0105_01_EN.docx...
  • Page 17: Menu: Zeigen Logbuch

    3.3.2 Sub-Menu: Lieferungen To review the delivery logbook (Lieferungen), select ‘View Log archives’ (Zeigen Logbuch) with the ▲ and ▼ keys from the MENU. On the next screen, select ‘Deliveries’ (Lieferungen) and enter the submenu by pressing ►. ▲▼► FW-C401-M_v0105_01_EN.docx...
  • Page 18: Menu: Zertifikat Ansehen (Qr-Code)

    This menu is meant to supply the user with a QR-code that can be scanned with a mobile phone. The QR-code will redirect him to a webpage containing actual certification and calibration data. If no (online) certification data is currently available, the QR-code will redirect to the Fluidwell website or the website configured via the configuration software.
  • Page 19: Menu: Zeigen Gerätinformationen

    Page 19 MENU: ZEIGEN GERÄTINFORMATIONEN To review detailed information about the C401, select ‘View Device Info’ (Zeigen Geräteinformation) with the ▲ and ▼ keys from the MENU and enter the submenu by pressing ►. ► Use the ▲ and ▼ keys to scroll through the information. When finished, press ◄ to return to the main menu.
  • Page 20: Menu: Setup Aufrufen

    Personnel must read and understand this manual before carrying out its instructions. • The C401 may only be operated by personnel who are authorized and trained by the operator of the facility. All instructions in this manual are to be observed.
  • Page 21 Page 21 3.7.2 SETUP-menu: Datum und Uhrzeit The C401 requires the valid time and date to be programmed in order to make valid custody transfer deliveries. To change the date and time, the service mode (access level Installer (Installateur) or Metrologic (Eichamtlich)) must be active.
  • Page 22 Coriolis) with the ▲ and ▼ keys from the SETUP-menu and enter the submenu by pressing ►. ► Use the ▲ and ▼ keys to scroll through the information. When finished, press ◄ to return to the SETUP menu. FW-C401-M_v0105_01_EN.docx...
  • Page 23: Configuration With Configuration Tool

    Only use the specified version of the C401 Configuration Tool, suitable for your version of the C401 firmware. To connect the C401 to the PC, simply connect an USB cable (USB A-Male to Mini-B Cable) to the USB Service Port as described in paragraph 4.6: USB connection. Make sure the C401 is powered up and Windows™...
  • Page 24: Ticket Printing

    TICKET PRINTING The C401 is able to print a ticket with all relevant data from the selected delivery. For this purpose an ASCII text driven printer must be connected. The C401 prints the data with a fixed width of 20 characters per line and several settings are available to configure the printer communications settings, custom text to print on the ticket and line or page terminations.
  • Page 25 Total delivered quantity (mass) under fault conditions (Faulty quantity) xxxxxxxxxx.xxx m3 Total delivered quantity (volume) under fault conditions Fehlerstatus: Int-E: 0x00000000 C401 Error field – all errors during delivery OR-ed Ext-E: 0x00000000 Flowmeter Error field – all errors during delivery OR-ed Ext-S: 0x00000000 Flowmeter SoftError field –...
  • Page 26: Installation

    Transient protection shall be provided that is set at a level not exceeding 140 % of the peak rated voltage value at the supply terminals to the equipment. Note: The C401 has a built-in transient protection at 140% of the peak rate voltage that satisfies this last Special Condition of Use.
  • Page 27: Mechanical Installation

    Page 27 MECHANICAL INSTALLATION Dimensions – Enclosure 4.3.1 Fig. 3: Dimensions – Aluminum enclosures. FW-C401-M_v0105_01_EN.docx...
  • Page 28: Electrical Installation

    The C401 must be installed in accordance with the EMC guidelines (Electro Magnetic Compatibility). • Service to the C401 may only be performed either with disconnected power supply, in safe area or in an area known to be non-hazardous. •...
  • Page 29: Terminal Connectors

    These terminals are used for the connection to the RS232 circuit of the On-Board Computer (OBC). Connect the OBC TXD line to terminal C2 and the OBC RXD line to terminal C3. Terminal C1 through C3 are electrically isolated with respect to the other circuits of the C401 with an insulation strength of 500V r.m.s..
  • Page 30: Usb Connection

    These terminals are used for the connection to the RS232 circuit of the printer. Connect the printer TXD line to terminal C8 and the printer RXD line to terminal C9. Terminal C7 through C10 are electrically isolated with respect to the other circuits of the C401 with an insulation strength of 500V r.m.s..
  • Page 31: Certifications

    “Transient protection shall be provided that is set at a level not exceeding 140 % of the peak rated voltage value at the supply terminals to the equipment”. Note: The C401 has a built-in transient protection at 140% of the peak rate voltage that satisfies this last Special Condition of Use.
  • Page 32 5.2.2 Switches The C401 is equipped with three switches that prevent unintentional changing of (metrological) parameters. Furthermore, a switch is installed to detect opening and closing of the enclosure door. All switch actions are logged in the event logbook with an indication of the new state. If the switch action also caused the Access Level to change, an additional record is logged with the new level.
  • Page 33 Access Level 0, 1 or 2 can be changed. Only a few parameters can be changed directly via the control panel on the device; most parameters can only be changed by using the Configuration Tool in combination with the right Access Level. FW-C401-M_v0105_01_EN.docx...
  • Page 34: Fig. 8: Outside Sealing Point

    5.2.4 Plombenplan (Sealing) The C401 can be sealed on the outside and on the inside. Although the sealing on the outside is not mandatory for custody transfer applications, it is advised that this seal is placed by the installer or owner of the installation to prevent any unauthorized access.
  • Page 35: Label Information

    • The first two digits of the serial number indicate the year of production. 5.3.1 External Labels The following label is fitted on the C401 enclosure, showing the type number, serial number and address. Fig. 10: External label 5.3.2 Internal Labels The label below can be found on the internal cover inside the enclosure.
  • Page 36: Maintenance

    To guarantee error free operation and correct time / date representation, it is required to replace the backup battery for the Real Time Clock (RTC) every 5 years. Inside the C401, a label next to the battery compartment indicates the month and year (MM/YYYY) before which the battery must be replaced.
  • Page 37: Changing Or Initializing An Uninitialized Clock

    (access level Installer (Installateur) or Metrologic (Eichamtlich)). In case the RTC backup battery is replaced, or in the extremely rare event that the C401 has lost its time information, the C401 will start-up with following screen on which the correct time and date must be entered: Entering the time and date is done in exactly the same way as indicated in paragraph 3.7.2: SETUP-...
  • Page 38: Technical Specification

    Power requirements Supply 16 – 27V DC ±10%. Maximum power consumption 2W Power supply needs to be fused outside the C401 enclosure with a 2AT (Time-delay) fuse. Backup battery (RTC) Coin cell. Renata type CR2477N (950mAh) or CR2450N (540mAh). Type Li MnO...
  • Page 39 • Current volume flow • Time / Date • Status • Flow rate alarms • Zeroing Flowmeter • Delivery report • Delivery Archive, error overview and event overview • Information Flowmeter • (language selection German / English / French) FW-C401-M_v0105_01_EN.docx...
  • Page 40: Problem Solving

    Page 40 PROBLEM SOLVING In this appendix, several problems are included that can occur when the C401 is going to be installed or while it is in operation. The C401 does not power up Check: the power supply. The C401is internally equipped with a self-resettable fuse, rated at 750mA.
  • Page 41: Declaration Of Conformity

    Page 41 DECLARATION OF CONFORMITY FW-C401-M_v0105_01_EN.docx...
  • Page 42: Index Of This Manual

    Page 42 INDEX OF THIS MANUAL Configuration manual version contents operational 6, 20, 26, 36 functional description power supply hardware version SETUP-level IP classification software version maintenance terminal connectors FW-C401-M_v0105_01_EN.docx...
  • Page 43: List Of Figures

    Page 43 LIST OF FIGURES Fig. 1: Overview of the C401 Dispenser Fig. 2: Control panel Fig. 3: Dimensions – Aluminum enclosures. Fig. 4: Grounding enclosure Fig. 5: Terminal connectors Fig. 6: USB Service port Fig. 7: Terminal covers Fig. 8: Outside sealing point Fig.
  • Page 44 Page 44 Fluidwell B.V. PO box 6 Voltaweg 23 Website: www.fluidwell.com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative: www.fluidwell.com/representatives FW-C401-M_v0105_01_EN.docx The Netherlands The Netherlands Copyright: 2021 - FW-C401-M_v0105_01_EN.docx...

Table of Contents