Do you have a question about the DN150 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Maurer DN150
Page 1
Power modules DN150 DN750 DN1100 DN1850 Translation from German manual...
Page 2
R e v i s i o n s Revisions Version Description 12.2008 First Version 09.2010 English Translation 05.2014 Description of the external enabling function Maximum load adapted for interfaces Warranty conditions adapted to current warranty sheet Chapter 5.5 supplemented (Customer-specific configuration) Additions to the analogue output 0 …1DC 0V Additions to the process monitoring level 1 / Chapter 6.5.3 05.2014...
Page 3
Improper installation, operation, maintenance or use of the machine can lead to body injury and property damage. Maurer Magnetic AG cannot be held liable for losses, consequential damages or cost resulting from or linked with improper installation, operation, maintenance or use.
4.2.1 Operator Protection ........................... 15 Coil module connector HAN 3/HAN 10 B ....................15 Fan connector ............................16 4.4.1 Fan connector DN150 (optional) ......................16 4.4.2 Fan connector DN750-1850 ....................... 16 Control signals ............................16 4.5.1 Coil module monitoring M8 ........................ 16 4.5.2...
Page 5
G e n e r a l I n f o r m a t i o n 6.5.4 PIN4 Fault ............................21 6.5.5 PIN5 Active ............................21 6.5.6 PIN7 Process OK (Process Monitoring Step 1, Optional) ..............22 6.5.7 PIN10 External enable signal ......................
Modification of the machine leads to loss of waranty. • Modification can lead to body injury and property damage • Modification of the parametrisation can lead to overheating and shutdown • Approval of modification only by Maurer Magnetic AG in writing Power Module DN Version 09.2019 Page 6/43...
S a f e t y i n s t r u c t i o n s 1.3 Notes on restrictive risks Endangerment Result or protection target Measures Life phase Endangerment Causes 1. Transport, Assembly, Installation Specify weight; the load capacity of During pick-up / transport, the centre the conveyor vehicle must be able to of gravity of the machine could be...
I n t e n d e d u s e Intended use The demagnetization power modules MM DN150…1850 are products developed and sold by Maurer Magnetic AG. They are intended to be used in combination with compatible demagnetization coil modules such as the MM CT-U, MM SE, MM RE, MM KE, MM VE series or custom-built coil modules.
FMT – Field Multiplicator Technology 3.1 Scope of delivery • Power module • Key for enclosure • Documentation (printed and digital) • Fixed base (optional) • Power cable (only DN150) • Additional options according to order scope Power Module DN Version 09.2019 Page 10/43...
D e v i c e c h a r a c t e r i s t i c s 3.3 MM DN750…DN1850 3.3.1 Controls Operation Lamp Ready Lamp Active Lamp Fault Lamp Cam Lock (2x) Main switch Pulse button Process OK lamp (optional) Power selector (optional)
I n s t a l l a t i o n Installation Mount device on and flat ground, stable and flat surface. • Ensure safe operation of device at all times • Operate power module only upright. Do not operate in horizontal position. Connection and disconnection of the coil module only with main switch off.
Table 2: Colour code supply connector DN150 4.1.2 Power cable (DN150) The DN150 can be connected to the grid with the provided power cable. If required, replace cable to comply with local regulation. Delivery worldwide: cable type (16A/250VAC) with safety plug (type E/F, CEE 7/7).
In case of false triggering of the RCCB, we recommend installation of a leakage compensation (See chapter troubleshooting). 4.3 Coil module connector HAN 3/HAN 10 B The coil module is connected with a HAN 3 (DN150) or HAN 10 B (DN750-1850) to the power module and latched. •...
Connector configuration and pin assignment according to circuit diagram 4.5.2 Sensor connector M12 The Sensor connector M12 allows the connection of an external pulse trigger (light barrier, capacitive sensor, ...). A suitable light barrier is available at Maurer Magnetic AG. • Voltage range see appendix •...
Agreement of modification only by Maurer Magnetic AG in writing DN power modules can be automated and integrated in many ways without modification. In case of questions regarding automation and integration contact Maurer Magnetic AG. Power Module DN Version 09.2019...
C o m m i s s i o n i n g Commissioning Indicates danger for persons with a cardiac pacemaker. Installation and commissioning of the device only by skilled personell. • Connect only to power source with correctly installed protection conductor •...
O p e r a t i o n Operation Indicates danger for persons with a cardiac pacemaker. Operate device only in enclosed premises accessible only by authorised personell. Connection and disconnection of the coil module only with main switch off. •...
O p e r a t i o n 6.1.2 Integration in production line Cycle times below specification may lead to overheating of the coil. Pulse triggering is blocked („Ready indicator dark / no „Ready“ signal, Alarm lamp red / Alarm signal). After cooldown pulse triggering is enabled again.
+24VDC at PIN2 for at least 100 ms starts the demagnetization. For continuous operation +24VDC is fed constantly. Continuous operation requires a special configuration by Maurer Magnetic. See chapter Continuous Demagnetization. 6.5.3 PIN3 Ready +24VDC at PIN3 indicates readiness of the machine.
O p e r a t i o n 6.5.6 PIN7 Process OK (Process Monitoring Step 1, Optional) Process Monitoring Step 1 monitors the current. +24VDC at PIN7 indicates when the target value is reached. It falls to zero after pulse completion simultaneously with the Active signal (PIN5).
O p e r a t i o n 6.5.10 Interface board D-Sub15 Fuse Power supply internal P1…P12 LED Status- display Fuse Power supply external S1 Enable Internal/external enable Figure 8: Interface board D-Sub15 6.5.11 Status LED P1… P12 description Troubleshooting and analysis in chapter troubleshooting.
O p e r a t i o n 6.5.12 Interface module fieldbus coupler Fieldbus coupler PROFI-NET 750-375 8-channel digital input/output 750-1502 End module 750-600 Figure 1: Fieldbus coupler (for example 750-375) Power Module DN Version 09.2019 Page 24/43...
Page 25
O p e r a t i o n Description Function Operation -1A1-X7:1 1 = ok DI 0.1 Ready (Temp. Monitoring & Enabling & FC = ok) -1A1-X7:2 1 = ok DI 0.2 Active (Demagnetization process on) -1A1-X7:3 1 = ok DI 0.3 Process ok -1A1-X7:4...
6.7 Continuous demagnetization Depending on the coil module the machine can be configured for continuous demagnetization. The configuration is set up by Maurer Magnetic before delivery. Continuous operation is controlled via D-Sub15 Control Interface. As long as +24VDC is supplied to PIN2 (Start) the demagnetization is active. When PIN2 drops to 0VDC the alternating field declines analogue to the pulse demagnetization.
O p e r a t i o n 6.8 Safety control Interruption of power supply during demagnetization pulse leads to immediate pulse disruption. • Parts in the vicinity of the coil are magnetised and need to be demagnetised once more •...
M a i n t e n a n c e Maintenance Maintenance, repairs and opening of the device only by skilled personell. • Wait 10 minutes for capacitor discharge before opening Opening of the inverter results in loss of warranty. 8.1 Daily maintenance interval 8.1.1 Visual check •...
20x5mm, slow-blow 4A Blown fuses 1FT1 and 1FT2 are indicated by an LED on fuse carrier. 8.4.2 Inverter replacement The Inverter is specially configured by Maurer Magnetic. For replacement the serial number of power and coil module is required. Power Module DN Version 09.2019...
M a i n t e n a n c e 8.5 Decommissioning Authorised and competent persons may only carry out decommissioning. Always observe the accident prevention regulations! 8.5.1 Disassemble The following steps are necessary for proper dismantling: • Switch off the system and secure it against unauthorised restarting •...
• Check power supply inverter. In DN750-1850 check motor circuit breaker • If Fault still indicates: open DN, record error message, contact Maurer Magnetic AG 9.5 Process OK lamp dark / no Process OK signal: • Process monitoring only works at 100% power setting (optional) •...
T r o u b l e s h o o t i n g False triggering of the RCCB, ELCB If a RCCB or ELCB is used it needs to be a Type B, suitable for protecting frequency inferters. Due to the built in frequency inverter, higher than normal leakage currents can occur at ~450 Hz.
Maximal current (RMS) corresponds to the value in the inspection protocol • Take a picture of the pulse (example see below) and send incl. setup current clamp (mV/A) to Maurer Magnetic AG for analysis Figure 9: Measurement demagnetization pulse 9.9 Malfunction external coil fan at Fan connector...
T r o u b l e s h o o t i n g 9.10 Error analysis LED interface board Function LED bright LED dark Error cause Colour Main switch „off“ Operatio No internal 24VDC power Internal 24VDC supply ok white supply Inspect fuses: 1F1,1FT1,1A1-F1...
S p e c i f i c a t i o n s 10 Specifications 10.1 General DN150 DN750 DN1100 DN1850 Dimensions (W x H x D) 300x400x210 mm 600x600x350 mm Weight 12 kg 45 kg 45 kg 50 kg...
Do not connect D-Sub interface to a PC verbinden. PC and power module may be damaged. D-Sub interfaces are potentially seperated and require 24VDC power supply provided by the customer. DN150 DN750-1850 0…24 VDC, <100mA Coil module monitoring M8 0…24 VDC, 200mA 0…24 VDC, 100mA...
S p e c i f i c a t i o n s 10.4.2 D-Sub15 control interface The signals (except PIN14/15) are potentially separated PIN1-13 PIN14/15 (not potentially separated) Nominal voltage 24VDC 10VDC 0…10VDC Voltage range 16…30VDC Maximal pre-fuse F2A (2A fast-acting) Internal fuse T315mA...
S p e c i f i c a t i o n s Figure 12: Configuration connector D-Sub15 10.4.3 D-Sub9 power setting interface (optional, DN750-1850) PIN1-09 Nominal voltage 24VDC Voltage range 19.2-28.8VDC Nominal voltage HIGH 24VDC Range HIGH 19.2-28.8VDC Nominal voltage LOW 0VDC Release voltage LOW...
S p e c i f i c a t i o n s 10.5 Ambient conditions 10.5.1 Operation DN150 DN750 DN1100 DN1850 -10 °C to 40 °C Temperature range ambient air No formation of ice in device. Relative humidity...
They must be used exclusively in combination expressly provided for. Maurer Magnetic AG cannot be held liable for direct or indirect damage, as well as consequential damage resulting from the false or improper use of the devices from the series MM DN150...1850.
Page 43
S t a n d a r d W a r r a n t y Maurer Magnetic Maurer Magnetic AG is specialised in demagnetization. We offer a varied choice of demagnetization processes. Metrology residual magnetism Measurement devices Zero-Gauss-Chambers MaurerClassic...