  • Page 1 Power modules DN150 DN750 DN1100 DN1850 Translation from German manual...
  • Page 2 R e v i s i o n s Revisions Version Description 12.2008 First Version 09.2010 English Translation 05.2014 Description of the external enabling function Maximum load adapted for interfaces Warranty conditions adapted to current warranty sheet Chapter 5.5 supplemented (Customer-specific configuration) Additions to the analogue output 0 …1DC 0V Additions to the process monitoring level 1 / Chapter 6.5.3 05.2014...
  • Page 3 Improper installation, operation, maintenance or use of the machine can lead to body injury and property damage. Maurer Magnetic AG cannot be held liable for losses, consequential damages or cost resulting from or linked with improper installation, operation, maintenance or use.
  • Page 4: Table Of Contents

    4.2.1 Operator Protection ........................... 15 Coil module connector HAN 3/HAN 10 B ....................15 Fan connector ............................16 4.4.1 Fan connector DN150 (optional) ......................16 4.4.2 Fan connector DN750-1850 ....................... 16 Control signals ............................16 4.5.1 Coil module monitoring M8 ........................ 16 4.5.2...
  • Page 5 G e n e r a l I n f o r m a t i o n 6.5.4 PIN4 Fault ............................21 6.5.5 PIN5 Active ............................21 6.5.6 PIN7 Process OK (Process Monitoring Step 1, Optional) ..............22 6.5.7 PIN10 External enable signal ......................
  • Page 6: Safety Instructions

    Modification of the machine leads to loss of waranty. • Modification can lead to body injury and property damage • Modification of the parametrisation can lead to overheating and shutdown • Approval of modification only by Maurer Magnetic AG in writing Power Module DN Version 09.2019 Page 6/43...
  • Page 7: Notes On Restrictive Risks

    S a f e t y i n s t r u c t i o n s 1.3 Notes on restrictive risks Endangerment Result or protection target Measures Life phase Endangerment Causes 1. Transport, Assembly, Installation Specify weight; the load capacity of During pick-up / transport, the centre the conveyor vehicle must be able to of gravity of the machine could be...
  • Page 8: Safety Electromagnetic Fields

    S a f e t y i n s t r u c t i o n s 1.4 Safety electromagnetic fields See manual coil module Power Module DN Version 09.2019 Page 8/43...
  • Page 9: Intended Use

    I n t e n d e d u s e Intended use The demagnetization power modules MM DN150…1850 are products developed and sold by Maurer Magnetic AG. They are intended to be used in combination with compatible demagnetization coil modules such as the MM CT-U, MM SE, MM RE, MM KE, MM VE series or custom-built coil modules.
  • Page 10: Device Characteristics

    FMT – Field Multiplicator Technology 3.1 Scope of delivery • Power module • Key for enclosure • Documentation (printed and digital) • Fixed base (optional) • Power cable (only DN150) • Additional options according to order scope Power Module DN Version 09.2019 Page 10/43...
  • Page 11: Mm Dn150

    Operation Lamp Ready Lamp Active Lamp Fault Lamp Main switch Process OK lamp (optional) Start button Figure 1: Controls DN150 3.2.2 Connectors Coil module monitoring M8 Control interface D-Sub15 Fan connector (optional) Power cable Sensor connector M12 Coil module connector...
  • Page 12: Mm Dn750

    D e v i c e c h a r a c t e r i s t i c s 3.3 MM DN750…DN1850 3.3.1 Controls Operation Lamp Ready Lamp Active Lamp Fault Lamp Cam Lock (2x) Main switch Pulse button Process OK lamp (optional) Power selector (optional)
  • Page 13: Installation

    I n s t a l l a t i o n Installation Mount device on and flat ground, stable and flat surface. • Ensure safe operation of device at all times • Operate power module only upright. Do not operate in horizontal position. Connection and disconnection of the coil module only with main switch off.
  • Page 14: Mounting

    Table 2: Colour code supply connector DN150 4.1.2 Power cable (DN150) The DN150 can be connected to the grid with the provided power cable. If required, replace cable to comply with local regulation. Delivery worldwide: cable type (16A/250VAC) with safety plug (type E/F, CEE 7/7).
  • Page 15: Dn Dn750

    In case of false triggering of the RCCB, we recommend installation of a leakage compensation (See chapter troubleshooting). 4.3 Coil module connector HAN 3/HAN 10 B The coil module is connected with a HAN 3 (DN150) or HAN 10 B (DN750-1850) to the power module and latched. •...
  • Page 16: Fan Connector

    Connector configuration and pin assignment according to circuit diagram 4.5.2 Sensor connector M12 The Sensor connector M12 allows the connection of an external pulse trigger (light barrier, capacitive sensor, ...). A suitable light barrier is available at Maurer Magnetic AG. • Voltage range see appendix •...
  • Page 17: Modification

    Agreement of modification only by Maurer Magnetic AG in writing DN power modules can be automated and integrated in many ways without modification. In case of questions regarding automation and integration contact Maurer Magnetic AG. Power Module DN Version 09.2019...
  • Page 18: Commissioning

    C o m m i s s i o n i n g Commissioning Indicates danger for persons with a cardiac pacemaker. Installation and commissioning of the device only by skilled personell. • Connect only to power source with correctly installed protection conductor •...
  • Page 19: Operation

    O p e r a t i o n Operation Indicates danger for persons with a cardiac pacemaker. Operate device only in enclosed premises accessible only by authorised personell. Connection and disconnection of the coil module only with main switch off. •...
  • Page 20: Integration In Production Line

    O p e r a t i o n 6.1.2 Integration in production line Cycle times below specification may lead to overheating of the coil. Pulse triggering is blocked („Ready indicator dark / no „Ready“ signal, Alarm lamp red / Alarm signal). After cooldown pulse triggering is enabled again.
  • Page 21: Process Ok Lamp (Process Monitoring Step 1, Optional)

    +24VDC at PIN2 for at least 100 ms starts the demagnetization. For continuous operation +24VDC is fed constantly. Continuous operation requires a special configuration by Maurer Magnetic. See chapter Continuous Demagnetization. 6.5.3 PIN3 Ready +24VDC at PIN3 indicates readiness of the machine.
  • Page 22: Pin7 Process Ok (Process Monitoring Step 1, Optional)

    O p e r a t i o n 6.5.6 PIN7 Process OK (Process Monitoring Step 1, Optional) Process Monitoring Step 1 monitors the current. +24VDC at PIN7 indicates when the target value is reached. It falls to zero after pulse completion simultaneously with the Active signal (PIN5).
  • Page 23: Interface Board D-Sub15

    O p e r a t i o n 6.5.10 Interface board D-Sub15 Fuse Power supply internal P1…P12 LED Status- display Fuse Power supply external S1 Enable Internal/external enable Figure 8: Interface board D-Sub15 6.5.11 Status LED P1… P12 description Troubleshooting and analysis in chapter troubleshooting.
  • Page 24: Interface Module Fieldbus Coupler

    O p e r a t i o n 6.5.12 Interface module fieldbus coupler Fieldbus coupler PROFI-NET 750-375 8-channel digital input/output 750-1502 End module 750-600 Figure 1: Fieldbus coupler (for example 750-375) Power Module DN Version 09.2019 Page 24/43...
  • Page 25 O p e r a t i o n Description Function Operation -1A1-X7:1 1 = ok DI 0.1 Ready (Temp. Monitoring & Enabling & FC = ok) -1A1-X7:2 1 = ok DI 0.2 Active (Demagnetization process on) -1A1-X7:3 1 = ok DI 0.3 Process ok -1A1-X7:4...
  • Page 26: Power Setting (Mm Dn750

    6.7 Continuous demagnetization Depending on the coil module the machine can be configured for continuous demagnetization. The configuration is set up by Maurer Magnetic before delivery. Continuous operation is controlled via D-Sub15 Control Interface. As long as +24VDC is supplied to PIN2 (Start) the demagnetization is active. When PIN2 drops to 0VDC the alternating field declines analogue to the pulse demagnetization.
  • Page 27: Safety Control

    O p e r a t i o n 6.8 Safety control Interruption of power supply during demagnetization pulse leads to immediate pulse disruption. • Parts in the vicinity of the coil are magnetised and need to be demagnetised once more •...
  • Page 28: Demagnetization

    D e m a g n e t i z a t i o n Demagnetization See manual coil module. Power Module DN Version 09.2019 Page 28/43...
  • Page 29: Maintenance

    M a i n t e n a n c e Maintenance Maintenance, repairs and opening of the device only by skilled personell. • Wait 10 minutes for capacitor discharge before opening Opening of the inverter results in loss of warranty. 8.1 Daily maintenance interval 8.1.1 Visual check •...
  • Page 30: Spare And Wear Parts

    20x5mm, slow-blow 4A Blown fuses 1FT1 and 1FT2 are indicated by an LED on fuse carrier. 8.4.2 Inverter replacement The Inverter is specially configured by Maurer Magnetic. For replacement the serial number of power and coil module is required. Power Module DN Version 09.2019...
  • Page 31: Decommissioning

    M a i n t e n a n c e 8.5 Decommissioning Authorised and competent persons may only carry out decommissioning. Always observe the accident prevention regulations! 8.5.1 Disassemble The following steps are necessary for proper dismantling: • Switch off the system and secure it against unauthorised restarting •...
  • Page 32: Troubleshooting

    • Check power supply inverter. In DN750-1850 check motor circuit breaker • If Fault still indicates: open DN, record error message, contact Maurer Magnetic AG 9.5 Process OK lamp dark / no Process OK signal: • Process monitoring only works at 100% power setting (optional) •...
  • Page 33: False Triggering Of The Rccb, Elcb

    T r o u b l e s h o o t i n g False triggering of the RCCB, ELCB If a RCCB or ELCB is used it needs to be a Type B, suitable for protecting frequency inferters. Due to the built in frequency inverter, higher than normal leakage currents can occur at ~450 Hz.
  • Page 34: Demagnetization Pulse Check

    Maximal current (RMS) corresponds to the value in the inspection protocol • Take a picture of the pulse (example see below) and send incl. setup current clamp (mV/A) to Maurer Magnetic AG for analysis Figure 9: Measurement demagnetization pulse 9.9 Malfunction external coil fan at Fan connector...
  • Page 35: Error Analysis Led Interface Board

    T r o u b l e s h o o t i n g 9.10 Error analysis LED interface board Function LED bright LED dark Error cause Colour Main switch „off“ Operatio No internal 24VDC power Internal 24VDC supply ok white supply Inspect fuses: 1F1,1FT1,1A1-F1...
  • Page 36: Specifications

    S p e c i f i c a t i o n s 10 Specifications 10.1 General DN150 DN750 DN1100 DN1850 Dimensions (W x H x D) 300x400x210 mm 600x600x350 mm Weight 12 kg 45 kg 45 kg 50 kg...
  • Page 37: Output

    0…24 VDC Voltage range Fuse protection Connector: Phoenix Contact SACC-E-MINFS-3CON-PG13/0,5 Phoenix Contact SACC-E-MINFS-5CON-PG13/0,5 Table 12: Fan connector Figure 10: Configuration Fan connector DN150 (left) / DN750-1850 (right) Configuration DN150 DN750-1850 - (not connected) - (not available) +24V - (not available)
  • Page 38: Control Signals

    Do not connect D-Sub interface to a PC verbinden. PC and power module may be damaged. D-Sub interfaces are potentially seperated and require 24VDC power supply provided by the customer. DN150 DN750-1850 0…24 VDC, <100mA Coil module monitoring M8 0…24 VDC, 200mA 0…24 VDC, 100mA...
  • Page 39: D-Sub15 Control Interface

    S p e c i f i c a t i o n s 10.4.2 D-Sub15 control interface The signals (except PIN14/15) are potentially separated PIN1-13 PIN14/15 (not potentially separated) Nominal voltage 24VDC 10VDC 0…10VDC Voltage range 16…30VDC Maximal pre-fuse F2A (2A fast-acting) Internal fuse T315mA...
  • Page 40: D-Sub9 Power Setting Interface (Optional, Dn750-1850)

    S p e c i f i c a t i o n s Figure 12: Configuration connector D-Sub15 10.4.3 D-Sub9 power setting interface (optional, DN750-1850) PIN1-09 Nominal voltage 24VDC Voltage range 19.2-28.8VDC Nominal voltage HIGH 24VDC Range HIGH 19.2-28.8VDC Nominal voltage LOW 0VDC Release voltage LOW...
  • Page 41: Ambient Conditions

    S p e c i f i c a t i o n s 10.5 Ambient conditions 10.5.1 Operation DN150 DN750 DN1100 DN1850 -10 °C to 40 °C Temperature range ambient air No formation of ice in device. Relative humidity...
  • Page 42: Standard Warranty

    They must be used exclusively in combination expressly provided for. Maurer Magnetic AG cannot be held liable for direct or indirect damage, as well as consequential damage resulting from the false or improper use of the devices from the series MM DN150...1850.
  • Page 43 S t a n d a r d W a r r a n t y Maurer Magnetic Maurer Magnetic AG is specialised in demagnetization. We offer a varied choice of demagnetization processes. Metrology residual magnetism Measurement devices Zero-Gauss-Chambers MaurerClassic...