REMOTE PHOTOCELL INSTALLATION GUIDE – LRPC12
Please read these instructions carefully prior to installation and keep for future reference
TECHNICAL INFO:
Power Source: 11-13V AC / DC
Power Frequently: 50-60Hz
Power Rating: 1500 VA or 5A Inductive load at 60uF
Switch on / Switch off: 10-30 lux / 60-90 lux
Maximum Load: 30W LED / 15W CFL / 60W Incandescent
IP Rating: IP44 (external sensor only)
Installation hole: 18-20mm
Cables: Box to Sensor (pre-wired) – Live In (Black), Live Out (Red) approx. 450mm length
Box to Connection Box (to be wired) – Live In (Brown), Live Out (Red), Neutral (Blue)
Dimensions: Box = 55 x 45 x 30mm (approx.) / Sensor = 26 x 22mm
IMPORTANT: Box must be installed inside a waterproof junction box / surround
PLEASE READ THESE INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION / MAINTENANCE
DO NOT USE WITH 240V MAINS – 12V ONLY (TRANSFORMER MAY BE REQUIRED)
Must be installed by a competent person. If in any doubt, consult a qualified electrician.
Install in accordance with IEE wiring regulations and current Building Regulations.
To prevent electrocution, switch off 12v power supply and remove the appropriate circuit fuse before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
This fitting is Protection Class III, 12V.
All connections should be made as watertight as possible to avoid electrical shortage.
Never exceed the wattage stated.
If a fitting is found to be damaged, cease use immediately.
The unit may get warm whilst on for a period of time.
Always take care during installation
Suitable for outdoor use when installed correctly in a light fitting or junction box.
Before drilling fixing holes, check that there are no obstructions hidden beneath
the mounting surface such as pipes or cables.
The chosen location of your new fitting should allow for the product to be
securely mounted and safely connected to the mains supply (lighting circuit).
This product is designed for permanent connection to fixed wiring.
recommend that the supply incorporates a switch for ease of operation.
RETURNS:
If purchased from a 3
rd
party, please contact your supplier. If purchased direct, contact us by phone or email:
Lumena Lights Ltd, Centre 33 Long March, Daventry, NN11 4NR
Our full returns policy is available on our website.
Waste Electrical Products should not be disposed of with household waste. Please check with your local authority or contact us
for more information. Please recycle packaging whenever possible.
Full product range & more information: www.lumenalights.com
WARNINGS
Tel: +44 1327 871161
2 YEAR
GUARANTEE
see website for
more details
Producer Registration Number:
WEE/KC3440XY
We
Email: sales@lumenalights.com
✔✔

Advertisement

loading

Summary of Contents for UMENA LRPC12

  • Page 1 REMOTE PHOTOCELL INSTALLATION GUIDE – LRPC12 Please read these instructions carefully prior to installation and keep for future reference TECHNICAL INFO: ✔✔ Power Source: 11-13V AC / DC 2 YEAR Power Frequently: 50-60Hz GUARANTEE Power Rating: 1500 VA or 5A Inductive load at 60uF...
  • Page 2 INSTALLATION: Select a suitable “open” mounting position so that the photocell is not affected by the light output of the fitting. Make a 20mm diameter hole in the mounting surface ensuring that the hole is free from burrs or rough edges. Remove the nut of the external PC by unscrewing anti-clockwise and lift off the top rubber washer.