Biobase BOV-V30F User Manual

Biobase BOV-V30F User Manual

Forced air drying oven
Hide thumbs Also See for BOV-V30F:

Advertisement

Forced Air Drying Oven
BOV-V30/45/65/125/230/625F
User Manual
BIOBASE GROUP
Version 2020.07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOV-V30F and is the answer not in the manual?

Questions and answers

Summary of Contents for Biobase BOV-V30F

  • Page 1 Forced Air Drying Oven BOV-V30/45/65/125/230/625F User Manual BIOBASE GROUP Version 2020.07...
  • Page 2: Preface

    4.Product operation is carried out according to the instruction manual. Disclaimer Biobase shall not be liable for any equipment failure or damage, or for any direct or indirect damage that may occur during the use of the equipment. 1.Malfunction or damage due to violation of the instructions, precautions, and intended use of this manual.
  • Page 3: Table Of Contents

    Content Preface..............................1 1. Installation and Operating Conditions....................3 2. Product Structure..........................3 3. Technical Parameters..........................4 4. Control Panel............................5 5. Instructions of Operation........................6 6. Wiring Diagram..........................9 7. Trouble Shooting..........................9 8. Warranty............................10...
  • Page 4: Installation And Operating Conditions

    1. Installation and Operating Conditions 1.1. This equipment should be placed in a room with good ventilation, shading, and cool conditions. The equipment and walls must be more than 10 cm away. Do not place flammable or explosive materials around it. 1.2.
  • Page 5: Technical Parameters

    3. Technical Parameters Model BOV-V30F BOV-V45F BOV-V65F BOV-V125 BOV-V230 BOV-V625F Capacity 125L 230L 625L Temp. Range RT+5~300℃ Temp. Precision 0.1℃ Temp. ±0.5℃ Fluctuation Ambient Temp. 5~40℃ Timing Range 1~9999min Shelves No. 2 pcs 3 pcs Power 800W 1200W 1600W 2300W...
  • Page 6: Control Panel

    4. Control Panel 1. Measured value display 6. Shift key, 2. Setting value display 7. Addend key 3. Alarm 2 indicator 8. Reduction key 4. Alarm 1 indicator 9. Main control output indicator 5. Set key 10. Auto tuning indicator...
  • Page 7: Instructions Of Operation

    5. Instructions of Operation The upper row of digital tubes displays the measured temperature, and the lower row displays the set temperature Press the SET key shortly, the temperature setting state will be entered The parameters can be corrected by the▼, ▲ keys, press the SET key to enter the time setting state Adjust time by After the▼, ▲...
  • Page 8 It need to re-adjust the temperature if the temperature fluctuations is more than 5 degrees, or can’t meet the requirements of the temperature. For example: After setting the required temperature of 100 degrees, press the button 5 seconds, AT indicator is on, then enter the auto tuning state.
  • Page 9 SCK,SCK= Standard value / Measure value. 3) P for setting proportional band. When take place regular oscillation of controlled temperature, the proportional band should be increased and if controlled temperature drifts irregularly we ought to decrease the proportional band. 4) I for setting the integral time. When the system takes place regular oscillation ought to I for setting proportional band.
  • Page 10: Wiring Diagram

    6. Wiring Diagram 7. Trouble Shooting Common failures and Solutions: Phenomena Causation Treatment Method No power supply a. poor plug contact or line broke a. Connect the plug and line. b. Fuse protector is broken. b. Change the fuse protector. No temperature a.
  • Page 11: Warranty

    8.2. Biobase would not be liable for any repair of damage caused by improper operation. 8.3. If the warranty has been expired, Biobase would still responsible for repair with relative charges. 8.4. Biobase would provide necessary technical data for maintenance companies or personnel trained...
  • Page 12 BIOBASE GROUP 2# building, No.9 Gangxing Road, High-tech Zone, Jinan City, Shandong Province, China Tel: +86-531-81219803/01 Fax: +86-531-81219804 Inquiry: export@biobase.com Complaints: customer_support@biobase.cc After-sales service: service_sd@biobase.cc; service_ivd@biobase.cc Web: www.biobase.cc/www.meihuatrade.com / www.biobase.com...