Advertisement

Quick Links

Packwise Smart Cap
Instruction manual
Version: BA_SC1_V02_ENG

Advertisement

Table of Contents
loading

Summary of Contents for Packwise Smart Cap

  • Page 1 Packwise Smart Cap Instruction manual Version: BA_SC1_V02_ENG...
  • Page 2 Imprint Packwise GmbH Antonstr. 25 01097 Dresden phone: +49 (0) 351 8967 5090 mail: service@packwise.de 1. Edition June 2021 © 2020 Packwise GmbH Subject to technical changes...
  • Page 3: Table Of Contents

    Table of contents General information about Packwise Smart Cap ............7 1.1. Performance description ......................7 1.2. Device data on the nameplate.................. 8 1.3. Modifications to the device ....................8 1.4. Operating instructions ......................9 Safety instructions ....................9 2.1.
  • Page 4 5.4. Attaching the Packwise Smart Cap with the locking plate ..........18 5.5. Inserting the Packwise Smart Cap on a mounted locking plate ........19 5.6. Detaching the Packwise Smart Cap from a mounted locking plate ......20 5.7. Activating the sensor and putting it into operation ..........20 5.8.
  • Page 7: General Information About Packwise Smart Cap

    General information about Packwise Smart Cap 1.1. Performance description The Packwise Smart Cap is a battery-powered sensor for filling level and temperature measurement, as well as location and position determination of mobile and stationary liquid containers or their filling goods.
  • Page 8: Device Data On The Nameplate

    QR code to call up the product URL Operating temperature Certifications (IP class, CE marking, production location) Disposal label Revision 1.3. Modifications to the device User modifications to the Packwise Smart Cap are not permitted. If modifications are necessary, contact Packwise. BA_SC1_V02_ENG...
  • Page 9: Operating Instructions

    Safety instructions This chapter lists general safety instructions that apply as basic rules of conduct when handling the Packwise Smart Cap. 2.1. Presentation of the warnings If there are risks of danger to persons or damage to the device, these are indicated by warnings.
  • Page 10: Intended Use

    This safety notice warns about damage to the device. 2.2. Intended use The Packwise Smart Cap is a battery powered sensor for filling level and temperature measurement as well as location and position determination of mobile and stationary liquid containers or their filling goods.
  • Page 11: Safety Instructions For Operation

    • The Packwise Smart Cap must not be operated in an explosive environment. • The Packwise Smart Cap may only be used in a technically perfect condition. • If any damage occurs, stop using the device immediately and contact Packwise.
  • Page 12: Areas Relevant For Approval

    2.8. Area relevant for approval If the Packwise Smart Cap is to be used in areas where approval is required, it must be checked before use whether the device has the appropriate approval. This information can be found on the nameplate, see section "1.2.
  • Page 13: Structure And Function

    Is firmly glued to the container to be with adhesive monitored. 3.2. Rear view No. Name Description Position of By removing the magnet, the Packwise Smart Cap is activated. the magnet and rubber Inserting the magnet deactivates the stopper Packwise Smart Cap.. BA_SC1_V02_ENG...
  • Page 14: Functional Principle

    • The filling level is determined by a radar sensor using . This method is used to determine the distance between the Smart Cap and the liquid, which is converted into the filling level with a container-specific bearing chart. •...
  • Page 15: Battery Information

    See also section "11.4 Battery" on page 27. Delivery and Storage The Packwise Smart Cap is assembled when delivered. The locking plate and O-ring are packed separately with the Packwise Smart Cap. BA_SC1_V02_ENG...
  • Page 16: Scope Of Delivery

    • Store in dry, dust-free environment • Do not store in potentially explosive areas Installation and activation The Packwise Smart Cap is assembled when delivered and can be attached to the container immediately. 5.1. Environmental conditions • The Packwise Smart Cap must not be operated in a potentially explosive environment.
  • Page 17: Positioning The Packwise Smart Cap

    5.3. Preparing the mounting surface Before installing the Packwise Smart Cap, make sure that the chosen surface is free of dust, dirt or moisture. 1. Clean the chosen surface with a suitable cleaning agent. 2. Dry the surface.
  • Page 18: Attaching The Packwise Smart Cap With The Locking Plate

    "5.7. Activating the sensor and putting it into operation" on page 20. Please note! The Packwise Smart Cap must be attached to the container within 1 minute after activation. After 1 minute the measurements start and the radar sensor is calibrated.
  • Page 19: Inserting The Packwise Smart Cap On A Mounted Locking Plate

    5.5. Inserting the Packwise Smart Cap on a mounted locking plate If a locking plate is already installed on the container, insert the Packwise Smart Cap as shown below: 1. Insert the o-ring into the locking plate. 2. Place the Packwise Smart Cap on the locking plate and press firmly until it snaps in.
  • Page 20: Detaching The Packwise Smart Cap From A Mounted Locking Plate

    5. Put the magnet aside and store it so you can deactivate the device again at a later time. IMPORTANT The Packwise Smart Cap must be attached to the container within 1 minute after activation. After 1 minute the measurements start and the radar sensor is calibrated to the environment.
  • Page 21: Deactivating The Sensor And Putting It Out Of Operation

    The Packwise Smart Cap is deactivated. The transmission of measured values is stopped. Operation There are no other operating options on the Packwise Smart Cap directly - apart from activation and deactivation. The adjustment of the transmission intervals as well as the activation and deactivation of functions is carried out exclusively via the web application Packwise Flow.
  • Page 22: Measurements During Operation

    6.1. Measurements during operation The Packwise Smart Cap is a stand-alone solution that records parameters without the need to install any other operating equipment. Activation of the Packwise Smart Cap automatically initiates the first measurement and data transfer. The measured values appear in the Packwise Flow platform no later than 10 minutes after activation of the sensor.
  • Page 23: Malfunctions

    1. Deactivate the Packwise Smart Cap by inserting the magnet. 2. Activate the Packwise Smart Cap by removing the magnet. Contact Packwise Support or - if available - your in-house contact person for the use of the Packwise Smart Cap.
  • Page 24: Firmware-Update

    The first temperature measurement after a firmware update can deviate strongly from the ambient temperature. The system will become stable after approx. 60 minutes. Repair and Shipping Repair of the Packwise Smart Cap by the user is not possible and not permitted. WARNING Fire hazard due to damaged batteries Visibly damaged devices must not be repaired or shipped by the user.
  • Page 25: Deactivation And Disposal

    2. Insert the magnet on the bottom side of the device to deactivate the measurements 3. Remove the locking plate from the container if it is no longer needed. 10.2. Disposal The Packwise Smart Cap must be disposed of in an environmentally friendly manner in accordance with the applicable laws. •...
  • Page 26: Shipping For Disposal

    Visibly damaged devices must not be shipped. • Deliver damaged devices directly to a collection point for electrical devices. 1. Check the Packwise Smart Cap for damage. 2. Always contact the manufacturer before shipping the device. Technical data 11.1. Device characteristics...
  • Page 27: Connectivity (Transmission Of Measured Values)

    11.3. Connectivity (transmission of measured values) Function Value Mobile connection 2G GPRS/EDGE 4G LTE-M1 (LTE Cat-M1) 4G LTE-NB1 (NB-IoT) GNSS GPS, Glonass, BeiDou, Galileo Bluetooth WLAN IEEE 802.11 b/g/n Firmware Updates over the Air (FOTA) 11.4. Battery Characteristics Value non-rechargeable battery Battery Primary 3.7 V lithium thionyl chloride (Li-SOCl2) battery, composed of 1 (one) "D"...
  • Page 28: Appendix

    Appendix 12.1. Order information Tel: +49 (0) 351 8967 5090 Packwise GmbH Email: service@packwise.de Antonstr. 25, Product Name: Packwise Smart Cap V1 01097 Dresden 12.2. Contact data Packwise GmbH Tel: +49 (0) 351 8967 5090 Antonstr. 25, Email: service@packwise.de 01097 Dresden 12.3.
  • Page 29: Declaration Of Conformity

    Germany erklären hiermit gegenüber unseren Kunden, dass das Produkt / herewith declare to our customers that the product Beschreibung / Description: Smart Cap / IIOT Datenverarbeitungsgerät / Information Technology Equipment Typenbezeichnung / Type designation: Packwise Smart Cap V1 die Bestimmungen folgender Richtlinien des Europäischen Parlaments und des Rates erfüllt / complies with the following European Directives of the European Parliament and...
  • Page 30 Die Übereinstimmung des Produktes mit den Anforderungen der Richtlinie wird durch die technische Dokumentation sowie die Einhaltung folgender Normen nachgewiesen / The technical documentation and compliance with the listed standards below prove the conformity of the product with the requirements of the directives EN 62368-1 : 2014/AC : 2015/A11 : 2017;...
  • Page 32 +49 (0) 351 8967 5090 Packwise GmbH service@packwise.de Antonstr. 25 www.packwise.io 01097 Dresden, Germany...

Table of Contents