Structure of external links ....................5 Terms and Definitions ....................6 Introduction ........................8 1 General information and technical specifications of DUT-E S7 ......... 11 1.1 Purpose of use, operation principle and application area .......... 11 1.2 Exterior view and delivery set ................13 1.3 Design .......................
Page 3
Annex B Electromagnetic compatibility of BLE-module ............69 Annex C Explosion protection of DUT-E S7 ..............70 Annex D SPN of DUT-E S7 Radiobox RS Functional modules ..........71 D.1 Self-diagnostics FM ..................... 71 D.2 Fuel level sensor FM .................... 73 D.3 Fuel level control FM ...................
Android devices (instead of Service S7 DUT-E service mobile application) is added. • DUT-E S7 technical specifications and the delivery set are updated. 01.2020 Information on DUT-E S7 Radiobox RS wireless interface and its use together with DUT-E S7 wireless fuel level sensors is added.
S7), model code — 07 manufactured by JV Technoton, Minsk, Republic of Belarus. Model code of DUT-E S7 is identified by third and fourth digits of its serial number engraved at its measuring probe or printed on its packing label (see figure 1).
Page 9
• conformity with European and national automotive standards. See figure 2 for identification codes for DUT-E S7 ordering. Figure 2 — DUT-E S7 order identification codes Example of DUT-E S7 ordering identification codes: “Fuel level sensor DUT-E S7 L = 1000 mm”...
Page 10
Manual. ATTENTION: Manufacturer reserves the right to modify DUT-E S7 specifications that do not lead to a deterioration of the consumer qualities without prior customer notice. DUT-E S7 fuel level sensor. Operation manual. Version 4.0...
5 years without using any external power sources; power is supplied only from the inbuilt battery. Data from DUT-E S7 can be received at a distance of up to 50 meters by unlimited number of various receiving devices (Telematics units, Android-smartphones/tablets etc.), which are...
Page 12
General information and technical specifications of DUT-E S7 / Purpose of use, operation principle and application area a) example of fuel volume monitoring in Vehicles tanks b) example of fuel volume monitoring in fixed tanks Figure 4 — Application areas of DUT-E S7...
– 1 pc. Figure 5 — DUT-E S7 delivery set * 1 pc. is for initial DUT-E S7 mounting and 1 pc. as a spare part. The delivery set may include just 1 gasket of 4 mm. ** Exterior of seal can be different.
General information and technical specifications of DUT-E S7 / Design 1.3 Design Figure 6 — Structure of DUT-E S7 Inside measuring “head” of sensor (1): electronic measuring unit, BLE module for wireless data transfer using S7 Technology and built-in battery (see figure 6).
General information and technical specifications of DUT-E S7 / Technical specifications / Main specifications 1.4 Technical specifications Powered of DUT-E S7 only by the built-in battery. DUT-E S7 can be used in the conditions of temperate and cold climate. For resistance to mechanical impact DUT-E S7 is shake and shockproof.
General information and technical specifications of DUT-E S7 / Technical specifications / Data composition of DUT-E S7 output message 1.4.2 Data composition of DUT-E S7 output message DUT-E S7 wireless fuel level sensor transmits data by means of Technology, without integration with receiving devices and without acknowledgement of data reception.
Page 17
General information and technical specifications of DUT-E S7 / Technical specifications / Data composition of DUT-E S7 output message values of the sensor output message may be calculated according to the formula (1) using attributes from table 4. Parameter value = SPN Content ∙ Factor (Resolution) + Offset Table 4 —...
General information and technical specifications of DUT-E S7 / Technical specifications / Compatibility with receiving devices 1.4.3 Compatibility with receiving devices DUT-E S7 can be used with receiving device (Android smartphones/tablets, Telematics units, GPS tracker and other devices for data receiving, logging and displaying), which have Bluetooth 4.X and high.
2.1 Exterior inspection prior to works start It is necessary to conduct DUT-E S7 exterior inspection for the presence of the possible defects arisen during transportation, storage or careless use. Contact the product supplier if there any defects.
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / BLE-module activation 2.3 Wireless transfer of sensor indications to the Android device For wireless monitoring of DUT-E S7 by means of Technology, first, download the Fuel Tank...
Page 23
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / BLE-module activation Area of magnetic key impact Apply the magnetic key to the cover of the sensor “head” for 1 s a) during the activation of the “Manufacturing” mode...
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Establishment of communication between the sensor and the Android device 2.3.2 Establishment of communication between the sensor and the Android device WARNING: All settings made in the Fuel Tank Monitor application are not recorded into the sensor, but are only saved in the memory of the Android device in the profile file of a specific sensor (see 2.3.4).
Page 25
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Establishment of communication between the sensor and the Android device During DUT-E S7 operation, signals of indicator time of receiving last message from the sensor on the Android device should be displayed in Fuel Tank Monitor app (see table 5).
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Interface of Fuel tank monitor application 2.3.3 Interface of Fuel Tank Monitor application Tools Panel Navigation Menu Information Button to return to the Configuration window of accessible...
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Operations with the sensor Profile 2.3.4 Operations with the sensor Profile The DUT-E S7 Profile is the collection of all settings of a specific sensor. The Profile menu serves to perform operations with DUT-E S7 profile.
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Calibration of the measuring system 2.3.5 Calibration of the measuring system The calibration of the measuring system is necessary for correct displaying of the fuel level measurement readings by a specific Android device.
Page 29
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Calibration of the measuring system 4) To calibrate minimum (lowest) point of level measurement, press button in Sensor calibration bar. ATTENTION: When the measuring system calibrating to minimum level, there should not be fuel residues on surface of tubes of probe.
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Calibration of fuel tank 2.3.6 Calibration of fuel tank Fuel Tank Monitor app recalculates the measured value of fuel level into the fuel volume in the tank according to the calibration table.
Page 31
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Calibration of fuel tank IMPORTANT: In case of replacing old Android device, it is necessary to copy profile of particular sensor into memory of new Android device (see 2.3.4). Alternatively, fuel tank calibration should be repeated with new Android device.
Page 32
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Calibration of fuel tank RECOMMENDATION: Tank calibration using DUT-E ATS-3 automatic calibration station reduces the calibration error to ±0.5 % of the tank volume and also reduces...
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Adaptation of indications for specific conditions of exploitation 2.3.7 Adaptation of indications for specific conditions of exploitation To adapt indications of the selected DUT-E S7 sensor (see 2.3.2) for specific conditions of...
Page 34
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Adaptation of indications for specific conditions of exploitation Slider contact to activate/disable the thermal correction function Field to enter the thermal correction coefficient Icon to enter the window of...
Page 35
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Adaptation of indications for specific conditions of exploitation Signs to open windows of Events detection settings a) Events tab b) Settings for detecting c) Settings for detecting “Discharging”...
Page 36
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Adaptation of indications for specific conditions of exploitation The list of all Events recorded during work with DUT-E S7, before the working session with Fuel Tank Monitor application is completed, is displayed in the Indicator panel submenu (Events tab) (see figure 19 b).
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Monitoring of indications using the Android device 2.3.8 Monitoring of indications using the Android device IMPORTANT: Correct monitoring of indications with Fuel Tank Monitor application is possible only after the measuring system calibration (see 2.3.5) and entering the...
Page 38
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Monitoring of indications using the Android device The maximum number of control points displayed — 200. The number of points recorded in the log file — not limited.
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Summation of indications 2.3.9 Summation of indications The function of summation of the fuel volume indications measured by a group of DUT-E S7 sensors (up to 10 pcs.) is configured in Settings submenu (Group tab).
Page 40
DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Summation of indications Total indication of the fuel volume of the group of sensors Fuel volume readings of each sensor Button used to add a sensor...
To seal the sensor put the sealing cord through the special holes of the mounting plate and DUT-E S7 body. Then put the ends of the cord through the holes in the center of the plastic seal body. Latching the seal will lock the cord. Seal removal will be impossible without its damaging Figure 22 —...
The procedure of DUT-E S7 accuracy check requires filling/draining of the fuel tank and comparing sensor data with the actual amounts of filling/draining.
Malfunction diagnostics 5 Malfunction diagnostics WARNING: DUT-E S7 indications in the Fuel Tank Monitor application will be invalid if the measuring tubes are closed by conducting mud or water. To monitor the quality of performance of the selected DUT-E S7, the Self-diagnostics submenu is used in the Fuel Tank Monitor application.
Re-calibration of the fuel tank of Vehicle in this case is not required. DUT-E S7 repair works are carried out only by certified Regional Service Centers (RSC). Full list of RSC can be found at https://www.jv-technoton.com/.
1) Screen-filter dismantling should be done carefully to avoid breaking latches of fixator. 2) In case of repeated installation of DUT-E S7 — replace the old rubber gasket with a new one. DUT-E S7 fuel level sensor. Operation manual. Version 4.0...
ATTENTION: Mud coating inside the inner measuring tube does not affect DUT-E S7 normal operation. Examine the space between two tubes of measuring part and between measuring part and additional electrode for mud and paraffin.
Operating principle: DUT-E S7 Radiobox RS has an inbuilt BLE-module which receives signals in the continuous mode from wireless fuel level DUT-E S7 sensors (up to 2 pcs.) by means of S7 Technology, at a distance of up to 50 m. In accordance with user settings, the DUT-E S7 Radiobox RS automatically processes signals received and converts them into ready data for RS-232/RS-485 interface.
• volume of fuel, l; • volume of fuel related to the full tank, %. Besides the data on the fuel level in the tank, DUT-E S7 Radiobox RS transmit data on the current fuel temperature. The selection of the required data transmission mode and the user configuration of parameters of RS-232/RS-485 digital interface are conducted using Service S6 DUT-E service software version not earlier than 5.11 (see 7.6.2).
For uninterrupted data transmission in conditions of the Vehicle, it is recommended that the distance between DUT-E S7 Radiobox RS and DUT-E S7 sensors should not exceed 20 m. To fix DUT-E S7 Radiobox RS, make use of the self-adhesive clasps that are contained in the delivery set.
Page 56
DUT-E S7 Radiobox RS wireless interface / Electrical connection Figure 29 — Diagram of DUT-E S7 Radiobox RS electrical connection Table 8 — Designation of wires in OUT wire bundle Connector Connector Circuit Signal Contact Wire Marking Wire Color* Pinout...
For configuration of DUT-E S7 Radiobox RS it is required to connect to PC with S6 SK service adapter (see figure 30). Recommendations regarding DUT-E S7 Radiobox RS connection to the PC are similar to the...
Page 58
DUT-E S7 Radiobox RS and the PC. The software will search for devices connected to the PC and will display the Connection window containing the list of Units accessible for connection.
DUT-E S7 Radiobox RS wireless interface / Configuration / Connection parameters for RS-232/RS-485 interface 7.6.2 Connection parameters for RS-232/RS-485 interface To connect DUT-E S7 Radiobox RS Telematics terminal , you should configure parameters of the RS-232/RS-485 in the Interface submenu Service S6 DUT-E software (see figure 32): 1) Select the data transfer protocol from the dropdown list Output Protocol Type: Modbus or DUT-E COM (DUT-E COM by default).
(up to 2 pcs.) by means of Technology. To establish a connection with DUT-E S7 and to receive data from it, you need to perform the following actions: 1) In the submenu of Base S7 FM (see D.5) select the required sensor, in accordance with its serial number, from the Available Bluetooth Device List.
DUT-E S7 Radiobox RS wireless interface / Configuration / Summarization of readings of DUT-E S7 wireless sensors 7.6.4 Summarization of readings of DUT-E S7 wireless sensors Using Technology, DUT-E S7 Radiobox RS can summarize volume readings of the two tanks...
Page 62
In case the calibration table for the corresponding fuel tank is available, you can manually enter values of calibration points into the memory of DUT-E S7 Radiobox RS in the submenu of the FM Fuel level sensor (see D.2) (Calibration Table tab) (e.g. using readings of the Android device, see 2.3.6) or load them from the file (*.ttr).
+10 to +30 °C and relative humidity from 45 to 75 % at 25 °C. Do not store DUT-E S7 in the same room with substances that cause metal corrosion and/or contain aggressive impurities. DUT-E S7 shelf life must not exceed 24 months.
DUT-E S7 from mechanical damage and precipitation. When transporting by air, DUT-E S7 must be stored in heated pressurized compartments. Air environment in transportation compartments should not contain acid, alkaline and other aggressive impurities.
DUT-E S7 does not contain precious metals in amount that should be recorded. The inbuilt lithium-thionyl chloride battery of DUT-E S7 contains harmful substances and components that are hazardous to human health and environment. Battery must not be disposed of together with general domestic waste.
Ex marking Figure C.1 — Placing of Ex mark on DUT-E S7 3) DUT-E S7 application area in hazardous locations of classes 0, 1 and 2 according to IEC 60079-10-1:2006 (GOST IEC 60079-10-1-2011), categories of explosive IIA mixtures according to IEC 60079-20-1:2010 (GOST R MEK 60079-20-1-2011), according to Ex marking of equipment, IEC 60079-14:2007 (GOST IEC 60079-14-2011) and other regulatory documents governing the use of electrical equipment in potentially hazardous locations.
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Self-diagnostics FM Annex D SPN of DUT-E S7 Radiobox RS Functional modules Reception and processing readings of DUT-E S7 wireless sensors, transmission of ready data into RS-232/RS-485 digital interface,...
Page 72
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Self-diagnostics FM Unit of Name Factory value Clarification measure 521123 Line DUT-E Name of the product line. The line represents a group of similar products – fuel level sensors produced under general trademark DUT-E.
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Fuel level sensor FM D.2 Fuel level sensor FM Fuel level sensor FM — is designed for measurement of current values of fuel level, volume and temperature in the...
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Fuel level control FM D.3 Fuel level control FM Fuel level control FM — is designed to receive data on the measured total fuel volume of the Vehicle two tanks via RS-232/RS-485 interface.
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Vehicle power supply FM D.4 Vehicle power supply FM Vehicle power supply FM — is designed for monitoring of onboard power network voltage, current mode of power network, operation time of Vehicle in different power network modes, quantity of engine starts*, exceeding permissible time of continuous operation of starter*.
Page 77
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Vehicle power supply FM Table D.4 — Vehicle power supply FM. Displayed and/or editable SPN with the help of Service S6 DUT-E software Factory Unit of Name Range Clarification...
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Base S7 FM D.5 Base S7 FM Base S7 FM — is designed for reception of messages (PGN) from wireless Units by means of Technology. Figure D.6 — Example of the window of settings of Base S7 in Service S6 DUT-E software for DUT-E S7 Radiobox RS Table D.5 —...
Page 79
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Base S7 FM Unit of Name Factory value Clarification measure 521188 S6 Address (SA) Network address of DUT-E S7 selected by the user to establish communication with DUT-E S7 Radiobox RS using S7 Technology.
• run any resource-intensive applications on the PC. Service S6 DUT-E software will display appropriate message and automatically will disconnect DUT-E S7 Radiobox RS from PC in case the update is successful. DUT-E S7 Radiobox RS is ready for further operation.
Need help?
Do you have a question about the DUT-E S7 and is the answer not in the manual?
Questions and answers