Haier HSU-09LF03 Installation Manual

Haier hsu-09lf03: user guide
Hide thumbs Also See for HSU-09LF03:

Advertisement

Quick Links

Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

Accessory parts

No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
4X50
5
Steel nail, cement
6
4X25
Plastic cap
Screw
7
Drain-elbow
Cover
8
Cushion
9
10
Pipe supporting plate
11
Connecting cable
Note:Cooling only units don't have Drain-elbow
No.0010518285
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
Optional parts for piping
Mark
Parts name
2
A
Non-adhesive tape
Adhesive tape
B
1
Saddle(L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
1
Drain hose
E
F
Heating insulating material
6
Piping hole cover
G
4
1
Arrangement of piping directions
1
Left
4
1
1
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Rear left
Rear
right
Right
Below
The marks from
A
to
The distance between the indoor unit and the floor should be
more than 2m.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Attention must be paid to
the rising up of drain hose
in the figure are the parts numbers.
G
12.Reamer
A
C
D

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-09LF03

  • Page 1: Installation Manual Of Room Air Conditioner

    Installation Manual of Room Air Conditioner Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) Accessory parts Number Accessory parts articles Remote controller Mark R-03 dry battery Mounting plate Drain hose 4X50 Steel nail, cement 4X25 Plastic cap...
  • Page 2: Selection Of Installation Place

    Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-09LF03 HSU-12LF03 Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.
  • Page 3: Installation Of The Indoor Unit

    Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2.
  • Page 4: Fixing The Indoor Unit Body

    1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Lid for right piping Lid for under piping...
  • Page 5: Connecting The Indoor/Outdoor Electric Cable

    5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Indoor unit Indoor unit HSU-09LF03 Outdoor unit HSU-12LF03 connecting wiring: -mod 09-12: 3G1.0mm...
  • Page 6: Connection Of Pipes

    Outdoor unit 1.Installation of Outdoor Unit Drawing for the installation of indoor and outdoor units Install according to 2.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m.
  • Page 7: Purging Method

    Piping length Additional amount No need Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. using for 9k 12k 100g 2-way valve 6.35mm(1/4") 3-way valve 9.52mm(3/8") HSU-09LF03 HSU-12LF03...
  • Page 8: Power Source Installation

    1.Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible.

This manual is also suitable for:

Hsu-12lf03

Table of Contents