  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditione...
  • Page 2 Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 3: Specifications

    Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. All electrical repairs must be carried out by qualified electricians.
  • Page 4 L i g h t s running. H2SM-18R04/R2 T e s t r u n n i n g s w i t c h ( m a n u a l ) c o o l i n g...
  • Page 5: Parts And Functions

    10.The appliance must be installed on strong enough supporter. 11 .The wiring diagram is attached inside the machine. 12.For model HSU-24R04/R2 and H2SM-18R04/R2,the breaker of the air conditioner should be an air gap contact. Such means for disconnection must be incorporation in the fixed wiring according to the wiring rules.
  • Page 6: Clock Set

    N O T E : ( 1 ) T h e f o l l o w i n g f u n c t i o n s a n d r e l a t e d d i s p l a y s a r e n o t a v a i l a b l e : A U X I L I A R Y H E A T d i s p l a y , P O W E R / S O F T d i s p l a y , L O C K d i s p l a y . (2)If the Air conditioner don't have the function of the code ,press code B can cause it not available.
  • Page 7 N O T E : ( 1 ) T h e f o l l o w i n g f u n c t i o n s a n d r e l a t e d d i s p l a y s a r e n o t a v a i l a b l e : A U X I L I A R Y H E A T d i s p l a y , P O W E R / S O F T d i s p l a y , H E A L T H d i s p l a y . (2)If the Air conditioner don't have the function of the code ,press code B can cause it not available.
  • Page 8: Operation

    When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press...
  • Page 9 Operation Auto run, Fan operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL...
  • Page 10: Cool,Heat And Dry Operation

    Operation COOL,HEAT and DRY operation Recommendations: (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL Unit will run in operation mode displayed on LCD.
  • Page 11: Air Flow Direction Adjustment

    Operation (5) Air flow direction adjustment After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig. COOL About 10 Up and down (Use remote controller) Press SWING button, vertical flap will move within the range shown in the Fig.
  • Page 12: Timer Operation

    Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
  • Page 13 Operation TIMER ON-OFF TIMER ON-OFF (1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: TIMER ON TIMER OFF TIMER ON-OFF Select TIMER ON-OFF.
  • Page 14: Health Mode Operation

    BRIEF INTRODUCTION TO HEALTH OPERATION The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air...
  • Page 15: Emergency And Test Operation

    More than 23 Less than 23 If an air conditioner is a model for both cooling and heating. Cooling when the room temperature at the start of operation is above 23 Heating when the room temperature at the start of operation is below 23...
  • Page 16 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. will become 1 C higher than temp.
  • Page 17 Different models have different appearance Cleaning of unit casing Cleaning of remote controller Cleaning of air filter 1.Open inlet grille by pulling it upward. 3.Clean the filter Use a vacuum cleaner to remove dust,or wash the filter with water. After washing, dry the filter completely in the shade.
  • Page 18: Replacement Of Air Purifying Filter

    Replacement of Air Purifying Filter 1.Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Detach old Air Purifying Filter 4.Attach old Air Purifying Filter Put air purifying filter appliances into the...
  • Page 19: Maintenance

    Maintenance Better use of air conditioner Proper room temperature. Closing of doors and windows during operation Never fail to observe the followings Do not sprinkle water over the unit. Do not pull power plug. Cleaning of the air filter. P r o p e r t e m p e r a t u r e Effective use of the timer.
  • Page 20: Troubleshooting

    When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable.