Installation; Components List; On-Site Preparations; On-Site Confirmation - Hisense HCCS-H64H2C1M Installation & User Manual

Hi-mit ii adapter
Table of Contents

Advertisement

3. Installation

3.1 Components list

When unpacking, please check if all the following items are complete and intact.
Item
Figure
Quantity
The device is provided along with four AC plugs complying with British standard, European standard,
American standard, Australian standard, as well as two bolts and two expansion plugs.
NOTE

3.2 On-site preparations

Following items should be ready before installation.
Item
DC12V power line
H-NET commu. cable
485 commu. cable
Wireless router
Internet cable

3.3 On-site confirmation

Select a place with the consent of customer and also suitable for the adapter installation.
• Check the installation location and power
supply.
• Check if all the embedded lines are ready.
• Check if the air conditioner can run properly.

3.4 Installation procedure

1) Drill as per the figure in the selected wall
(diameter: 6mm, pitch of holes: 44mm).
2) Position the expansion plugs into the holes
and insert the bolts with 3~5mm protruding
from the expansion plug.
3) Screw out the fixing bolts from the base of
adapter, and remove the bottom cover, then
perform wiring according to diagram.
Adapter
Installation Manual
1
Specification
preferred: 0.75mm
2
above, shielded twisted pair
preferred: 0.75mm
2
above, shielded twisted pair
preferred: 0.75mm
2
above, shielded twisted pair
preferred: TP-Link, Netgear
100Base-TX
Power Adapter
1
not necessary, applicable only when using DC12V
backup power interface
necessary, for communication with A/C,
commu. distance < 1000m
not necessary, for communication with electric meter,
commu. distance < 600m
necessary, make sure have access to internet. When
adapter connects to router in a wireless manner,
straight line distance < 15m, and supports only 2.4GHz
not necessary, applicable only when connecting to internet
with cable, commu. distance < 50m
• Check if WiFi covers when wireless connection is
adopted.
•Check if air conditioner is powered off.
•When power adapter is adopted, please confirm the
type of plug on-site, and select a proper AC plug.
Wall
4
Accessory Pouch
1
Requirements
Pitch of holes
44mm
Bolt protruding
from the wall
3mm
1

Advertisement

Table of Contents
loading

Table of Contents