uniprox JT06 Instruction Manual

uniprox JT06 Instruction Manual

Weight activated brake knee manual lock

Advertisement

Quick Links

ST&G USA Corp.
2691 Saturn Street
Brea, CA 92821, USA
Distributed by:
Uniprox GmbH & Co.KG, H.-Heine-Str.4, 07937 Zeulenroda-Triebes
Ein Unternehmen der Bauerfeind Gruppe – www.uniprox.de
MDSS GmbH
Schiffsgraben 41
30175 Hannover, Germany
Qualität und Funktion
Gebrauchsanweisung
Instruction Manual
JT06 Weight activated
brake knee manual lock
unique prosthetic solutions
A company of the Bauerfeind Group

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JT06 and is the answer not in the manual?

Questions and answers

Summary of Contents for uniprox JT06

  • Page 1 ST&G USA Corp. MDSS GmbH 2691 Saturn Street Schiffsgraben 41 Brea, CA 92821, USA 30175 Hannover, Germany Distributed by: Uniprox GmbH & Co.KG, H.-Heine-Str.4, 07937 Zeulenroda-Triebes unique prosthetic solutions Ein Unternehmen der Bauerfeind Gruppe – www.uniprox.de A company of the Bauerfeind Group...
  • Page 2 5. General safety instructions warrant the function. 1. Intended Use The JT06 Weight activated brake knee is designed for prosthetic limb users in the K1 The medical device is designed for multiple use to a single patient. • and K2 activity scales with a maximum body weight of 125 kg. The knee joint has a Fitting/service of the medical devise is only allowed by a certificated orthopedic •...
  • Page 3 7.1 STANCE PHASE – 6. Alignment and Set-Up Brake Sensitivity Stance Adjustment Alignment for the L1311A should be adhered to so as to enable a stable and safe functioning The brake sensitivity adjustment is to fine tune the prosthesis for the wearer. The recommended alignment is 10mm anterior amount of load required during stance phase to to the Knee Center which will have the weight line on the centerline along the length of the pylon.
  • Page 4 Reassess knee function during walking and adjust accordingly. Note: Failure to adequately secure the set screw (b) when disabling the locking lever Important: flexion and extension must be possible at all settings! (a), can result in loss of function of the knee and / or makes it impossible to move the Resetting Friction to factory setting: Friction adjustment screw should be reset to be knee freely.
  • Page 5 The product satisfies the requirements of Regulation (EU) 2017/745 of the European Parliament and of the Council (MDR) and bears the CE mark. All major incidents related to the product needs to be informed to Uniprox and/or ST&G USA Corp. as well as to the competence European Authority.

This manual is also suitable for:

4 610 130 00 12 000

Table of Contents