The battery is replaceable, thus the complete lantern disposal is not necessary at the end of battery’s life. Standard fixings allow for a quick beacon replacement. Designed in accordance with the IALA Recommendations. MCL100 USER MANUAL MCL100 Pág.
Do not start a new step in the assembly tasks until having completed the previous one. Cover the solar module with an opaque material during the installation to prevent electricity generation. Check the stability of the entire equipment mounted prior to its use. USER MANUAL MCL100 Pág.
Adjustable in lux. Solar charge regulation function: Regulation in 3 phases. Settings: PC, Programmer IR Modos de sincronización Version with optional GPS. MCL100-SYNC Energy management: Dynamic, according to latitude. Light intensity reduction due to low Configurable by the user. battery:...
3.1 .LIGHT SPECIFICATIONS. COLOR PEAK INTENSITIES cd D.V. 15º WHITE GREEN AMBER 3.2. OPTIONS Infrared (IR) programmer. PC programming kit. Fixing kit for 3 bolts in a 200mm diameter. Other specifications available under request. USER MANUAL MCL100 Pág.
Using an allen wrench to arrange for removal of the 6 screws securing the back of the beacon. Removal the top cover: Once the screws are removed manually withdraw the top of the beacon is attached to the battery. USER MANUAL MCL100 Pág.
Place the back cover of the beacon: Place the back cover facing it with the fixing holes and with the valve on the side where the battery is not located, pressing to fit the flange into its position of sealing and closure. USER MANUAL MCL100 Pág.
Besides, ensure not to catch the cable with the gasket. 4.3. PROGRAMMING MODES The MCL100 flashlight can be programmed using several methods: USING THE MFCOM SOFTWARE By PC, In order to program the flash character, it is required to select the desired rhythm in the 256 flash character table attached in the last pages of the manual.
Page 12
The closing of the beacon, must be done according to the instructions in 4.2. The MCL100 compact lantern can be programmed externally, with the MFCOM software for PC. Check the MFCOM manual for more details about the instructions for use. The parameters that can be programmed are: Rhythm of flashes selected from the character table.
The use of an adjustable wrench is required. A Phillips screwdriver is required to open the flashlight and a small flathead screwdriver for wiring. The MCL100 can be mounted on a flat surface which can resist 5 Kg minimum. Follow the next steps for the lantern mounting.
Page 14
The use of an adjustable wrench is required. A Phillips screwdriver is required to open the flashlight and a small flathead screwdriver for wiring. An adjustable span and a bubble level are required. The MCL100 can be mounted on a flat surface which can resist 5 Kg minimum. Follow the next steps: 1.
Mounting on a NON-levelled surface 6. Sun radiation The MCL100 solar system is composed by 4 nos. solar modules and one 12V AGM technology battery free of maintenance. The charge/discharge is controlled by the MF12 flasher including solar regulation function by a 3 steps charge system that helps to maximize battery lifetime.
Besides, as compact self-powered lanterns, all the elements that form them (battery, flasher, LED ...) are perfectly grouped and protected in the same module hermetically sealed and protected from external conditions. USER MANUAL MCL100 Pág.
Never accumulated discharge abrasives solvents cycles. containing alcohol solvents. Checking good Replacement of O-ring and condition of O-ring and moisture valve if necessary. moisture valve. Checking of the solar module loading. Grease fastening hardware. USER MANUAL MCL100 Pág.
For replacement of the existing battery by a new one, follow the instructions set out in section 4.1 Beacon start-up and 4.2 Beacon closing of this manual. Battery technology and battery performance according to the depth of discharge (DOD) and temperature are described below. USER MANUAL MCL100 Pág.
Page 19
They should not be thrown with ordinary waste and must be recycled always according to local and national regulations. MSM provides its customers with recycling and collection service for the removal of these products at the end of its lifetime.
Verify flasher configuration c) Verify internal wire. 4. The beacon lights but doen’t turned off since 24 hours: Possible reasons: a) Solar module dirtiness. b) MF06 flasher failure. Solutions: a) Solar panel cleaning. b) Flasher substitution. USER MANUAL MCL100 Pág.
Page 21
RS232 communication cable failure. b) PC or software failure. c) MF06 failure. Solutions: a) Check with other communication table. b) Reinstall software or try with other PC. c) Test MF06 flasher and substitute if necessary. USER MANUAL MCL100 Pág.
If corrosion appeared within the product warranty period, subject to the above limitations, MSM will replace all parts with such corrosion. Since the use of the product and maintenance conditions are outside the control of MSM, MSM will not accept any compensation for loss, damage or costs others than the replacements in the cases cited above.
Page 28
FLASH CHARACTER TABLE rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK USUARIO 1 USUARIO 2 USUARIO 3 USUARIO 4 USUARIO 5 USUARIO 6 FL1S 0,25 0,75 FL1,5S 0,50...
Page 29
rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL12S 1,20 10,80 FL12S 1,00 11,00 FL15S 1,00 14,00 FL15S 0,50 14,50 FL15S 2,00 13,00 FL15S 3,00 12,00 FL(2)3S 0,50...
Page 30
rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL(2+1)6S 0,30 0,40 0,30 1,20 0,30 3,50 FL(2+1)6S 0,50 0,50 0,50 1,50 0,50 2,50 FL(2+1)8S 0,50 0,50 0,50 0,50 1,50...
Page 31
rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL(4)10S 0,40 1,40 0,40 1,40 0,40 1,40 0,40 4,20 FL(4)10S 0,75 0,75 0,75 0,75 0,75 0,75 0,75 4,75 FL(4)10S 0,50...
Page 32
rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK LFL12S 2,00 10,00 LFL12S 3,00 9,00 LFL15S 4,00 11,00 MO(A)3S 0,50 0,50 1,50 0,50 MO(A)5S 0,50 0,50 1,50 2,50 MO(A)6S...
Page 33
rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK OC5S 3,00 2,00 OC5S 4,00 1,00 OC6S 4,50 1,50 OC6S 5,00 1,00 OC6S 4,00 2,00 OC8S 6,00 2,00 OC10S 6,00...
Page 34
rv.06 MF05 RHYTHM DUTY% DARK DARK DARK DARK DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK FL DARK VQ0,5S 0,20 0,30 VQ0,6S 0,30 0,30 VQ(3)5S 0,20 0,30 0,20 0,30 0,20 3,80 VQ(3)5S 0,30 0,30 0,30 0,30 0,30 3,50...
Page 36
LUMINOUS INTENSITIES 1,5 HOURS SUN 2 HOURS SUN 3 HOURS SUN 4 HOURS SUN MCL100-15º RV 06 MF05 nº RHYTHM DUTY% INTENSITY Cd INTENSITY Cd INTENSITY Cd INTENSITY Cd USER 1 15,0% 16 14 22 24 21 32 32 28 43...
Page 37
1,5 HOURS SUN 2 HOURS SUN 3 HOURS SUN 4 HOURS SUN MCL100-15º RV 06 MF05 nº RHYTHM DUTY% INTENSITY Cd INTENSITY Cd INTENSITY Cd INTENSITY Cd FL(2)10S 20,0% 12 11 16 18 16 24 24 21 32 FL(2)10S 20,0%...
Page 38
1,5 HOURS SUN 2 HOURS SUN 3 HOURS SUN 4 HOURS SUN MCL100-15º RV 06 MF05 nº RHYTHM DUTY% INTENSITY Cd INTENSITY Cd INTENSITY Cd INTENSITY Cd FL(4)20S 20,0% 12 11 16 18 16 24 24 21 32 FL(4)20S 30,0%...
Page 39
1,5 HOURS SUN 2 HOURS SUN 3 HOURS SUN 4 HOURS SUN MCL100-15º RV 06 MF05 nº RHYTHM DUTY% INTENSITY Cd INTENSITY Cd INTENSITY Cd INTENSITY Cd OC5S 80,0% OC6S 75,0% OC6S 83,3% OC6S 66,7% OC8S 75,0% OC10S 60,0% OC10S...
Page 41
Appliance: LED MARINE FLASHING LANTERN. MARCA: MEDITERRANEO SEÑALES MARITIMAS. BRAND MODELO COMERCIAL: MCL100. Commercial Name: Al que se refiere esta declaración está en conformidad con las siguientes normas: To which this declaration relates is in conformity with the following standards: EN61000-6-4(2007) EMISIÓN ELECTROMAGNÉTICA / EM Emission.
Need help?
Do you have a question about the MCL100 and is the answer not in the manual?
Questions and answers