  • Page 1 Instruction Manual FY-3DH Our equipment is approved by the following car manufacturers (China)
  • Page 2: Table Of Contents

    Contents 1. Precautions 2. Specifications 3. Installation 4. Controls 5. Operation 6. Troubleshooting 1) Troubleshooting 2) Lamp Tube Replacement 7. Exploded View 8. Circuit Diagram...
  • Page 3: Precautions

    1. PRECAUTION 1. Read this manual carefully before installing or using this equipment. 2. This equipment is designed for paint drying applications. Adjust to the correct temperature and check minimum safe distance from the heat source when using. Improper use may cause paint surface damage. 3.
  • Page 4: Specifications

    2. SPECIFICATIONS Model FY-3DH Input Voltage 220V / 1-ph / 50-60Hz Input Power 3 × 1000W 1200 × 1000mm Curing Area Temperature 35°C - 80°C 0min - 99mins adjustable Time Setting 10% - 100% Light Intensity Page 2...
  • Page 5: Installation

    3. INSTALLATION The shortwave infrared curing lamp is divided into 3 parts (a base, a column and a cassette). 1) Installation of the base. a. Open the packing of the base. b. Install the four wheels on the base respectively and tighten up the screws. Usually, the wheels with brakes should be mounted on the rear of the base.
  • Page 6: Controls

    4. CONTROLS 1. LCD display 2. Lamp selector (each lamp can be controlled separately) 3. Power adjustment 4. Time adjustment 5. Setting: - Press the button once, it will enter into "Routine" mode when the lamp is on. ① ② ③...
  • Page 7: Operation

    5. OPERATION 1. Automatic Mode a. Properly assemble the curing system according to the instruction (see page 3). b. Switch on the power supply. The system is ready to use when the graphic appears on the display screen as follows: 00: 00 POWER: 80% 00CM...
  • Page 8 5. OPERATION 2. Manual Mode a. Press the navigation buttons "Power +/- " and "Time +/-" when the lamp is ready to use to adjust the curing power and time. b. Press the button "Setting" to set the mode of "Routine" or "Pulse”. c.
  • Page 9: Troubleshooting

    6. TROUBLESHOOTING 1. Troubleshooting PROBLEM CAUSE SOLUTION a. Lamp tube damaged a. Check lamp tube Lamp tube does not work b. Lamp is not plugged in b. Plug in lamp holder c. Control silicon damaged c. Check control silicon Lamp tube does not turn a.
  • Page 10: Lamp Tube Replacement

    6. TROUBLESHOOTING 2. Lamp Tube Replacement a. Prepare cassette for replacement. b. Remove the grille of cassette. c. Remove the plates from both ends of the cassette. d. Remove the fixed plates from both ends of the cassette. e. Loosen fixed screws and cut off connections, the lamp can be replaced.
  • Page 11: Exploded View

    EXPLODED VIEW NAME NAME NAME NAME Column Aluminium handle Lifter Cover plate (upper) Top cover Clamping bar Front wheel Circuit board Plastic band Side panel U-type base Sensor box Upper connecting rod Cassette Back wheel Connector Plastic handle Cover plate (lower) Adjustable hand wheel Lower connecting rod Handle...
  • Page 12: Circuit Diagram

    CIRCUIT DIAGRAM Page 10...