We have a visual pager display that is no longer working/showing lights is any kind or number.
1 comments:
Mr. Anderson
May 11, 2025
If the Visual-Pager 900 Series is not displaying any lights, follow these troubleshooting steps:
1. Check Power Source: Ensure the keypad is powered on, as the display gets power from the keypad. If the keypad is off, the display will also be off.
2. Verify Wiring Connections: Make sure all displays and keypads are correctly wired together. Confirm that SIGNAL and GROUND polarity are maintained.
3. Inspect Cable Type: Use 16 or 18 AWG paired wire and connect them to the two-conductor terminal block on the back of the display.
4. Use of RCA Connectors: If using RCA connectors, ensure the coaxial cable is securely connected.
5. Check for Booster Amp Requirement: If the number of displays exceeds the keypad’s power capacity, use a Model 160 Booster Amp.
6. Refer to Connection Diagrams: Confirm all connections match the system’s connection diagrams.
These steps help identify power or connection issues preventing display lights.
This answer is automatically generated
Subscribe to Our Youtube Channel
Summary of Contents for Microframe Corporation Visual-Pager 900 Series
Page 1
SERIES 900 INSTALLATION and SPECIFICATION GUIDE Microframe Corporation 604 South 12th Street Broken Arrow, OK 74012 Local: 918-258-4839 Toll Free: 800-635-3811 Website: www.microframecorp.com E-mail: support@microframecorp.com Manual No. D0910-7010 Revision Date: 09/2013 Control: 1.6 D0910-7010 *D0910-7010*...
Page 2
Your Microframe System is warranted against failure due to defects in workmanship or material for a period of one (1) year from the date of purchase. Microframe Corporation will repair or replace any defective unit. Obvious abuse or mishandling of the unit is NOT covered by this warranty.
How to Connect Multiple Keypads to a Display How to Connect a Display to a Keypad Keypad Operation Keypad Options Visual-Pager® Display Operation Error Codes and Troubleshooting Chart Microframe Corporation 604 South 12 Street Broken Arrow, OK 74012 800-635-3811 www.microframecorp.com...
Each display has 5.5-inch tall digits viewable from up to 125 feet and is encased in an extruded- aluminum case. Microframe Corporation 604 South 12 Street Broken Arrow, OK 74012 800-635-3811 www.microframecorp.com...
Turn off the keypad and check the wiring. Otherwise, type “123”, press “ENTER”, and verify that “123” shows on all the displays. See the “Troubleshooting Chart” at the end of this manual for additional assistance. Microframe Corporation 604 South 12 Street...
T o DELETE a paging n umber , press DELETE when the n umber is being displa y ed. n umber is being displa y ed. 906\ax\9703.ai Microframe Corporation 604 South 12 Street Broken Arrow, OK 74012 800-635-3811 www.microframecorp.com Series 900...
Ty-Wrap is inside the case as shown. The slide-on cover has a notch for the wires to fit through. 1 1/2 AMP FAST BLO Ty-Wrap 904\ax\9703.ai Microframe Corporation 604 South 12 Street Broken Arrow, OK 74012 800-635-3811 www.microframecorp.com Series 900...
2. A/C—Remote 24 VAC Input used when a adapter other than the wall mounted one supplied with the system is required, such as an attic-mounted adapter installation. Note: Each keypad must operate off its own power adapter. Keypads cannot share power adapters. Microframe Corporation 604 South 12 Street...
Enter,Y – When user types a number, keypad assumes Enter Mode. When user has typed all 6 digits, automatically adds number. Delete,Y – When user types a number, keypad assumes Delete Mode. When user has typed all 6 digits, automatically deletes number. Microframe Corporation 604 South 12 Street Broken Arrow, OK 74012 800-635-3811 www.microframecorp.com...
If you are using RCA connectors, then connect the coaxial cable to either "Signal" connector on the remote display. To add a second display, connect one end of the signal cable to the other RCA phono connector on the first display and the other end to either connector on the next display. Microframe Corporation 604 South 12 Street...
Does the keypad work when connected has erratic numbers to the display with a shorter (3 feet long) piece of cable? If so, the problem is in the wiring. Microframe Corporation 604 South 12 Street Broken Arrow, OK 74012 800-635-3811 www.microframecorp.com...
Need help?
Do you have a question about the Visual-Pager 900 Series and is the answer not in the manual?
Questions and answers
We have a visual pager display that is no longer working/showing lights is any kind or number.
If the Visual-Pager 900 Series is not displaying any lights, follow these troubleshooting steps:
1. Check Power Source: Ensure the keypad is powered on, as the display gets power from the keypad. If the keypad is off, the display will also be off.
2. Verify Wiring Connections: Make sure all displays and keypads are correctly wired together. Confirm that SIGNAL and GROUND polarity are maintained.
3. Inspect Cable Type: Use 16 or 18 AWG paired wire and connect them to the two-conductor terminal block on the back of the display.
4. Use of RCA Connectors: If using RCA connectors, ensure the coaxial cable is securely connected.
5. Check for Booster Amp Requirement: If the number of displays exceeds the keypad’s power capacity, use a Model 160 Booster Amp.
6. Refer to Connection Diagrams: Confirm all connections match the system’s connection diagrams.
These steps help identify power or connection issues preventing display lights.