Page 1
DZ 20-A V2 ZEITSCHALTUHR TIMER SWITCH Bedienungs- und Sicherheitshinweise Operation and Safety Notes TIJDSCHAKELKLOK KOPPLINGSUR Bedienings- en veiligheidsinstructies Bruksanvisning och säkerhetsanvisningar RELOJ TEMPORIZADOR IDŐZÍTŐ KAPCSOLÓ Instrucciones de utilización y de seguridad Kezelési és biztonsági utalások ΧΡΟΝΟ ΙΑΚΟΠΤΗΣ Υποδείξεις χειρισμού και ασφαλείας...
Introduction ........Page 37 Intended use ......... Page 37 Control elements ........Page 38 Technical Data ........Page 39 Safety notices ....... Page 40 Control- and display elements ..........Page 42 Control elements ........Page 42 Displays + Explanation ......Page 42 Operating mode function .....
Page 3
Operation ......... Page 50 Switching to the clock function .... Page 50 (De) activating continuous operation ..Page 51 Configuring programs ......Page 52 Switching the random function on and off ..........Page 56 Cleaning ..........Page 58 Disposal ..........Page 59 Manufacturer ........
Page 4
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 35 04.07.16 11:03...
Page 5
List of pictograms used: Observe the warning and safety instructions! Attention! Risk of electric shock! Do not dispose of electric equip- ment in the household waste! Use indoors -10T40 Ambient temperature Micro-switch with a contact opening width of < 3 mm 36 GB DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 36 04.07.16 11:03...
Timer Switch Digital – for indoors Introduction Intended use The device is intended as a digital weekly timer switch for use in enclosed, dry rooms and designed for private use. It is not suita- ble for commercial use. Only operate the device individually.
Control elements (Fig. A) LCD display MINUTE button RST / RCL button RANDOM button ON / AUTO / OFF button Socket Plug (reverse) Timer button CLOCK button WEEK button MASTERCLEAR button HOUR button LCD display (Fig. B) Weekday display R symbol S symbol Seconds display ON –...
PROGRAM Hours display CLOCK Program number AM – PM ON – OFF Technical Data Model designation: DZ 20-A V2 Operating voltage: 230–240 V ~ 50 Hz Switched voltage: 230–240 V ~ 16(2) A Switching capacity: max. 3600 W Ambient temperature: -10 °C to 40 °C...
Programs: 10 ON / OFF program sets Battery: NiMH 1.2 V > 100 h indoors: EU compliant: Safety notices Children are not able to understand the dangers arising from improper use of electric devices. Never leave children unsupervised when using electric devices. Only plug the device into safely installed sockets.
Page 10
Do not open the device. Opening the device will void the warranty. The device contains a rechargeable bat- tery. A defective rechargeable battery must be replaced by the manufacturer. Do not touch the device with wet hands or bring into contact with water.
Control- and display elements Control elements MASTERCLEAR button This button will delete all time and program settings. Displays + Explanation Weekdays The abbreviations on the LCD display mean: MO Monday TU Tuesday WE Wednesday TH Thursday FR Friday SA Saturday SU Sunday 42 GB DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 42...
Page 12
R Symbol The R symbol indicates random switching is activated. The R symbol means random. In this mode the device will switch the con- nected loads on and off at different intervals. S symbol Indicates the clock has been set to summer time.
Program number Indicates the program number in PROGRAM function. AM – PM Indicates the hour mode. ON – OFF Indicates the switching state: ON = turn-on time, OFF = turn-off time. The switching state is only visible under program function. Operating mode function The different operating modes are: AUTO = automatic program operation,...
Program function This function allows the on- and off times to be programmed for the connected load. Clock function This function shows the current time in the LCD. Preparation To start up the device you must: 1. Charge the device. 2.
Charging the device Insert the plug into a mains socket. Charge the rechargeable battery for 14 hours. Reset all settings Note: The device does not need to be con- nected to the mains to configure the settings. Reset all settings Press the MASTERCLEAR button with a pen or other pointy object.
All settings cleared. Setting the current time Note: Hold the HOUR, MINUTE button for faster programming. Press and hold the CLOCK button. Set the current day of the week with the WEEK button. Set the hour with the HOUR button. Set the minute with the MINUTE button.
Setting standard and summer time Setting summer time Simultaneously press the CLOCK and ON / AUTO / OFF buttons. The will advance the hour display by one hour and the S symbol disap- pears. Setting standard time Simultaneously press the CLOCK ON / AUTO / OFF buttons.
Setting the hour mode The LCD can display the current time in 12- or 24-hour mode. In 12-hour mode AM means before 12 noon, PM after 12 noon. The default is 24 hour mode. Setting to 12 hour mode Simultaneously press the TIMER CLOCK buttons.
Setting to 24-hour mode Simultaneously press the TIMER CLOCK buttons. The LCD will stop showing AM or PM Operation Switching to the clock function The LCD automatically switches back to clock function if a function is not used for more than 30 seconds. Press the CLOCK button to manually go to the clock function.
(De) activating continuous operation This device has the following operating modes: – Continuous operation, – Automatic program operation The default is automatic program operation. You can switch the device to continuous operation separate from the programs. Activating continuous operation Repeatedly press the ON / AUTO / button until the LCD reads DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 51...
Deactivating continuous operation Repeatedly press the ON / AUTO / button until the LCD reads Activating automatic program operation Repeatedly press the ON / AUTO / button until the LCD reads AUTO AUTO: device is switched off. AUTO: device is switched on. Configuring programs You can set up to 10 ON / OFF programs.
Page 22
A program consists of the switch-on and switch- off time. Both times must be programmed to be able to use a program. Be sure the time settings of the various pro- grams do not overlap. If the times overlap, the switch-on time takes priority. 1.
Page 23
– An individual weekday, – One of the following combinations: MO, TU, WE, TH, FR, SA, SU MO, TU, WE, TH, FR SA, SU MO, TU, WE, TH, FR, SA MO, WE, FR TU, TH, SA MO, TU, WE TH, FR, SA MO, WE, FR, SU 4.
Page 24
7. After entering the program, confirm with the CLOCK button or wait 10 sec- onds until the current time is displayed. Set current status If the clock should be on at the current time (ON), the ON / OFF / AUTO button must be pressed until ON appears on the screen.
Press the RST / RCL button. Press the TIMER button to select the switch-off time. Press the RST / RCL button. Press the CLOCK button to confirm the entry and exit. Restoring programs Programs can only be restored whilst deacti- vated.
Page 26
during this time period, which alternately switches on and off with an interval of 10 to 31 minutes. Activating the random function Check if the device is in AUTO mode. If not, set to AUTO (see “Setting the operating mode“). Press the RANDOM button.
Page 27
Cleaning ATTENTION! RISK OF ELECTRIC SHOCK! Discon- nect the device from the mains before cleaning. ATTENTION! RISK OF ELECTRIC SHOCK! Do not allow liquids to enter the device. Liquids entering can result in a short circuit. ATTENTION! Danger due to harsh cleaners.
Disposal Do not dispose of electric equipment in the household waste! In accordance with European Directive 2012 / 19 / EC relating to old electrical and electronic appliances, used electrical equip- ment must be collected separately and recy- cled in an ecologically compatible way. Contact your local authorities for information on how to dispose of the appliance at the end of product life.
Page 29
lectra-t ag Blegistr. 13 CH-6340 Baar www.dvw-service.com 60 GB DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 60 04.07.16 11:03...
Page 30
Blegistrasse 13 CH-6340 Baar 0452827 / 616 DZ 20-A V2 Stand der Informationen · Last Information Update · Stand van de informatie · Informationsstatus · Estado de las informaciones Információk állása · Έκδοση των πληροφοριών: 07 / 2016 Ident.-No.: 0452827 07 / 2016-DE / GB / NL / SE / ES / HU / GR...