Advertisement

Quick Links

6.0
7.0
9.0
INSTRUCTION MANUAL · EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SyncraSDC 6.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICE SyncraSDC 6.0

  • Page 1 INSTRUCTION MANUAL · EN...
  • Page 2 INDEX KEY FEATURES SAFETY INSTRUCTIONS COMPONENTS SPARE PARTS PUMP INSTALLATION: USE AND REGULATION IN LINE APPLICATIONS MAINTENANCE SPECIAL MAINTENANCE AND REPLACING GROUP ROTOR CHECK LIST BEFORE USING CONTRALL APP CONTROLLER USE AND PUMPS REGULATION WI-FI SET UP LOSS OF WI-FI CONNECTION AND CONTROLLER RESET VOICE COMMANDS CONTROLL APP AND ALERTS SYSTEM CONTRALL APP INFOS...
  • Page 3: Key Features

    Dear Customer, thank you for choosing the new pump SYNCRA SDC. By purchasing this new generation of SYNCRA Silent pumps you will benefit from a high- tech and cutting-edge product. The pumps are speed control and can be set up with the use of the controller included. Furthermore by using your domestic Wi-Fi network you can download the new SICCE App: CONTRALL and manage the pump with your smarthphone ( Android system or iOS).
  • Page 4: Safety Instructions

    SAFETY INSTRUCTIONS SYNCRA SDC is made in conformity with the national and international safety standard regulation. 1) Always isolate the pump from the mains electricity before installing or carrying out any maintenance. Power to the pump must be supplied through a Residual Current Device (RCD) with a rated residual operating current not exceeding 30mA.
  • Page 5 COMPONENTS SYNCRA SDC pumps are designed favoring the almost total dismantling of their components, to facilitate proper use and maintenance and ensure a long life. Below is the list of the individual parts and spare parts (Pic.B): 1. Motor body completely submersible and insulated by epoxy resin; 2.
  • Page 6: Spare Parts

    SPARE PARTS SPARE PARTS Rotor + ceramic shaft + O-ring SGR0222 SGR0218 SGR0217 Bottom bearing + hook SVE0054 SVE0052 Hook SPL0024 O-ring for prechamber and rotor SVE0055 SVE0053 Prechamber with closing ring SPL0097 SPL0095 Anti-vibration silicon feet SVE0033 (4 pcs.) Hose fittings for rigid and flexible pipes STR0029 Protective grid...
  • Page 7: Pump Installation

    PUMP INSTALLATION: USE AND REGULATION SYNCRA SDC can be remotely set up by using the controller or by downloading the new SICCE CONTRALL App.( iOS-Android) For the physical installation of the pump it is necessary to proceed as follows: - Unwind the power cord of the pump in an area where it will not be damaged in any way.
  • Page 8 IN LINE APPLICATIONS It is recommended to place the pump in spaces where there is a proper ventilation and the pump is not directly exposed to heat sources. Place the pump so as to prevent too long idraulic pipings, which IN LINE would reduce its performance.
  • Page 9: Maintenance

    MAINTENANCE For the periodic maintenance of the pump, unplug the pump from the electric socket and then remove the pump from water. 1) Lift the plastic ring of the pump’s volute pulling the tab outwards (Pic.6) 2) Remove the ring (Pic.7) 3) Remove the volute of the pump by turning and simultaneously pulling forward (in the case of fouling this may take more pressure).
  • Page 10 7) Put the ring in place with the biggest teeth facing the pump and close it by pressing on the tab until you hear a “click”. (Pic.9) Any damage to the o-rings, even small, can seriously endanger the pump performance. In this case, it is best to replace them. IMPORTANT: The build-in circuit board of the pump has been programmed to provide 3 levels of protection: Protection against rotor’s blockage: In case of malfunction which...
  • Page 11 SPECIAL MAINTENANCE AND REPLACING GROUP ROTOR Follow this instruction for an accurate rotor kit cleaning or replacing Repeat the opening actions as indicate in Maintenance’ section, steps 1,2,3,4. To easily remove the bottom bearing, we suggest to leave the pump submersed with water and Pump Clean for a while to make soften debris or limestone.
  • Page 12 CHECK LIST BEFORE USING CONTRALL APP • Check the distance between the device and the wireless router (Wi-Fi network). A long distance may weaken the signal strength and take a long time to record the device, in worst scenario the installation may fail. •...
  • Page 13 CONTROLLER USE AND PUMPS REGULATION By connecting the power supply to the controller, all the LEDs light up once. After about 20 seconds the Wi-Fi symbol will start to flash slowly to indicate that it is ready and awaiting the set-up. After the configuration, once connected to the Wi-Fi network, the led will make 5 rapid flashes every 5 seconds.
  • Page 14 WI-FI SET UP CONTRALL App Free download Select MY DEVICES and tab on + Choose these SYNCRA SDC Read the text and then Confirm PROCEED. Next: select the WIFI network you wish to link the pump and the WIFI psw. Give a name to your pump and confirm with DONE.
  • Page 15: Voice Commands

    LOSS OF WI-FI CONNECTION AND CONTROLLER RESET In case Wi-Fi connection is lost, the pump will continue working and the user will receive a notification via email if this warning has been activated in the App CONTRALL.The connection will be restored automatically as soon as the wireless network is available again. WIFI AND CONTROLLER RESET Remove power from the controller. Press and hold down the “+”...
  • Page 16 CONTROLL APP AND ALERTS SYSTEM Notifications in real-time with a complete alert system can be activated in CONTRALL App profile session. Alerts in real time will be sent in case of: - Aquarium temperature outside of the custom set range - Blocked Rotor protection - Dry running protection - Loss of Wi-Fi signal...
  • Page 17 DEEP CLEANING & TIPS FOR LONGER LASTING USE SICCE PUMP CLEAN It’s important to keep your SICCE Pump in prime operating condition to ensure long-life and efficient operation. Over time, natural mineral deposits will form in the filter surface and rotor, and if untreated, may cause undesirable operation or even failure.
  • Page 18: Online Help

    ONLINE HELP Watch our tutorial videos on THE SICCE YOU TUBE official channel www.youtube.com/SICCEspa INSTRUCTIONS FOR THE CORRECT DISCHARGE OF THE PRODUCT ACCORDING TO EU DIRECTIVE 2002/96/EC When used or broken, the product does not have to be discharged with the other waste. It can be delivered to the specific electric waste collection centers or to dealers who give this service.
  • Page 19: Warranty

    WARRANTY SICCE guarantees this product (see Exclusions below) to the original purchaser against defects of materials and workmanship for a period of three (3) years from the date of original purchase, except for the pump’s impeller, which is guaranteed for a period of six (6) months. This warranty is limited to repair or replacement (at SICCE’s option) of defective product only and does not cover loss of aquarium life, personal injury, property loss, or damage arising from the use of the product.
  • Page 20 WARRANTY SEAL AND SIGNATURE OF RESALE DEALER DATE OF PURCHASE ____ / ____ / ____ month year INDEX SYNCRA SDC · 6.0 · 7.0 · 9.0 INSTRUCTION MANUAL · EN...

This manual is also suitable for:

Syncrasdc 7.0Syncrasdc 9.0

Table of Contents