50 foot (15 metre) 4 conductor telephone cord. The ACS Panel provides you with a finer degree of both monitoring and operating control over the standard Control Panel shipped with the PROsine 2.5 Inverter•Charger. If you purchased a PROsine 3.0, it comes standard with the ACS Panel in place of the standard Control Panel.
Page 5
Button What it does: Comments: 1. Selects the menu level, or You can then use the buttons to move through the ENTER screens at that level. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Page 6
RESET condition that led to the alarm. Indicator LEDs The function of the indicator LEDs on the PROsine ACS panel are as follows: Status Description: Comments: FAULTS PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Page 7
PROsine AC output is powered directly from the electric utility power. Status Description: Comments: CHARGER CHARGE ON when charger is operating in charger mode READY Batteries are charged. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Page 8
Refer to the PROsine Inverter•Charger Owner’s Manual for detailed information regarding battery equalization. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
5. Press to move up one level in the menu. Press to select a ESCAPE ENTER level in the menu and use the buttons to scroll through the options at that level. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
USER SETTABLE: from 5 to 30 amps in 1 BREAKER SIZE: amp increments to match the AC service SET AT: 30 A breaker the unit is connected to. This setting can limit the maximum charge current. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Note: The DC input ranges are factory configured for the maximum range allowed for proper operation of the PROsine 2.5/3.0 Inverter•Charger. The installer may wish to narrow this range of operation for optimization of the system. For example, the LO ALARM setpoint could be raised to 11.5V if you want an early warning that the battery is being discharged.
Press ENTER then CHASSIS TEMP. to change between C and F. Display information only used for system SYSTEM INFO: troubleshooting DC BUS: 220Vdc PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
ACS Panel. The parameter can now be adjusted. Exiting to the top level menu, where voltage and current are displayed will disable installer mode. Disable installer mode before putting the unit into service. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
3. If you purchased the ACS Panel as an accessory to be used with your PROsine 2.5, the ACS Panel and standard supplied panel can both be used at the same time. Either connect the standard panel to the OUTPUT jack on the back of the ACS Panel, or connect the standard panel to the REMOTE output connector jack on the side of the PROsine Inverter•Charger.
(two batteries in series). 006,065 Micro Processor Remote display cable is Unplug all cables from communication error pinched or has loose REMOTE OUT Jacks on side connection. of PROsine. If problem persists, call Statpower. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Page 16
10 V with 1. Neutral and Line respect to Earth Ground. connection is reversed. 2. Long and/or loose conn- ections to the utility/shore power can result in a high neutral voltage. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Page 17
Disconnect AC and DC an overload condition. power to the PROsine. Reconnect DC and AC power after 15 minutes. If the problem persists, contact Statpower Customer Service. 2. Internal Fault. 2. Contact Statpower. PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual...
Statpower without prior authorization by Statpower. Repair or replacement are your sole remedies and Statpower shall not be liable for damages, whether direct, incidental, special, or consequential, even though caused by negligence or fault.
CANADA You must obtain a Return Authorization Number from Statpower before returning the PROsine ACS Panel directly to Statpower. Do not return the PROsine ACS Panel to Statpower without first obtaining a Return Authorization Number. Returned goods received without an RA# will be shipped back collect. When you contact Statpower to obtain service, be prepared to supply the serial number of your PROsine ACS Panel.
Need help?
Do you have a question about the Prosine 2.5 and is the answer not in the manual?
Questions and answers