Installation Manual
Installation and commissioning
Use a standard European backbox with screws. The distance between the screws needs to be 60mm. The
depth required is 24mm, however additional depth should be reserved for connecting the device.
Mount Sentido with the temperature sensor upwards. If not, make sure to indicate the position of the
temperature sensor when programming the Sentido Cresnet Module. Use screws with a countersunk, flat head
and do not apply too much force as this might deform the plastic housing.
Connect the keyapd to Cresnet bus according the Crestron installation guidelines.
Please refer to the software manual to configure the Sentido switch.
Note
When using the dual Sentido front cover, disable sensor 2 and 3. Only sensor 1 and 4 will be used.
How to mount the Sentido front cover (not included)
Only install the Sentido front cover while the switch is not powered.
Push the Sentido front cover firmly onto the Sentido switch. The front cover is fixed to the switch by the clipsing
system.
Make sure the cover is mounted using all 4 clips.
Power the device once the front cover is mounted. Calibration will be initiated.
Calibration
In order to function properly, the sensors of the Sentido Cresnet® need to calibrate to the environment. This
calibration starts when bus power is applied, when a cover is installed or can be forced when the sensors detect a
touch for more than 40 seconds.
During calibration, the RGB led will light up blue and slowly fade up and down. Make sure not to touch the cover
when the calibration process is ongoing! At the end of calibration, the RGB led will blink green. The keypad is now
ready to be used.
How to remove the Sentido front cover
We provide the 'tube' tool to easily remove the Sentido front cover.
Do not use a screwdriver or other tools, as these might damage the cover.
Technical data
Current consumption Cresnet®:
Peak during startup: 4W
During operation 0.4W
Ambient temperature:
Operation: -5°C to 45°C
Storage: -15°C to 55°C
Transport: -15°C to 55°C
basalte bv | hundelgemsesteenweg 1A | 9820 merelbeke | belgium
t +32 (0)9 385 78 38 | f +32 (0)9 329 66 95 | www.basalte.be | info@basalte.be
Max. humidity: 93% relative humidity,
no moisture condensation
Protection class: II
Type of protection: IP 20
Certification: CE