2019-4018
2019-11-01
ECOLAB Aqua Balance Pure Comfort Mineral Pool & Spa System, Model 2.0
For swimming pools, a range of 1.0 - 3.0 ppm of free available chlorine
For spas, a range of 3.0 - 5.0 ppm of free available chlorine must be maintained.
READ THE LABEL AND OPERATING MANUAL BEFORE USING
REGISTRATION NO. 29705 PEST CONTROL PRODUCTS ACT
WARNING: Operating the Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System
without water flow through the cell can cause a buildup of flammable gases
NOTICE TO USER: This pest control product is to be used only in accordance with the
directions on the label. It is an offence under the Pest Control Products Act, to use
this product in a way that is inconsistent with the directions on the label.
Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System Model
2.0
CHLORINE GENERATOR
CONTROLS BACTERIA AND ALGAE
Swimming Pool (and Spa) Waters
COMMERCIAL
A maximum of 113,600 L of water can be treated with
Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System, Model 2.0
Maximum output of hypochlorous acid equivalent to 0.896 kg
of free available chlorine per day
must be maintained.
KEEP OUT OF REACH OF CHILDREN
which can result in FIRE OR EXPLOSION.
Ecolab Inc.
1 Ecolab Place
St. Paul, MN 55102
1-800-354-5326
in
Model 2.0,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aqua Balance Pure Comfort 2.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ecolab Aqua Balance Pure Comfort 2.0

  • Page 1 READ THE LABEL AND OPERATING MANUAL BEFORE USING REGISTRATION NO. 29705 PEST CONTROL PRODUCTS ACT WARNING: Operating the Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System Model 2.0, without water flow through the cell can cause a buildup of flammable gases which can result in FIRE OR EXPLOSION.
  • Page 2 ECOLAB Aqua Balance Pure Comfort Mineral Pool & Spa System USER’S GUIDE MODEL 2.0...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION……………………………………………………………….4 WARRANTY INFORMATION…………………………………………………5 SAFETY INFORMATION……………………………………………………6-7 PREPARING YOUR WATER BEFORE INSTALLATION……………….8-9 SALT CHART FOR CORRECT MAINTENANCE…………………………10 TOOLS AND PARTS REQUIRED FOR INSTALLATION………………..11 INSTALLING YOUR SYSTEM – PLUMBING………….……………….12-13 ELECTRICAL………….………………14 SPECIFICATIONS AND FUSE SIZING……………………………………..15 STARTING THE SYSTEM………………………………………………….…15 GENERAL OPERATION………………………………………………………16 MAINTENANCE AND CLEANING………………………………………..…17...
  • Page 4 READ THE LABEL AND OPERATING MANUAL BEFORE USING REGISTRATION NO. 29705 PEST CONTROL PRODUCTS ACT WARNING: Operating the Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System Model 2.0, without water flow through the cell can cause a buildup of flammable gases which can result in FIRE OR EXPLOSION.
  • Page 5: Introduction

    This electrode must only be used on this model of chlorine generating device. READ THE LABEL AND REFER TO OWNER'S MANUAL OF THE Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System Model 2.0, BEFORE USING. Ecolab Inc., 1 Ecolab Place, St. Paul, MN 55102 INTRODUCTION Ecolab Inc.
  • Page 6: Warranty Information

    WARRANTY INFORMATION ECOLAB system carries a limited 3 year warranty 1. 3 year warranty on assembly of electrical components and cell housing. 2. 1 year on all electrical items. 3. 2 years or 15,000 hours, which ever occurs first, pro-rated hourly, on titanium electrodes.
  • Page 7: Safety Information

    SAFETY INFORMATION PLEASE READ THE FOLLOWING SAFETY INFORMATION CAREFULLY! WARNING! • Only a certified technician may install and service your ECOLAB system. • Modifying your ECOLAB system in anyway may cause bodily injury and will void your warranty. • Warning: To reduce the risk of injury, do not allow children to operate this device.
  • Page 8 • When replacing the cell, only use replacement cells having a label that clearly states that it is a replacement cell for the chlorine generating device Ecolab Aqua Balance Pure Comfort Mineral Pool & Spa System Model 2.0, REGISTRATION NUMBER 29705, PEST CONTROL PRODUCTS ACT.
  • Page 9: Preparing Your Water Before Installation

    PREPARING YOUR WATER BEFORE INSTALLATION ECOLAB saline chlorination systems operate by utilizing the sodium chloride that has been added to the pool water, to produce sodium hypochlorite (liquid chlorine), through the process of electrolysis. In order for your ECOLAB system to operate correctly, sodium chloride (salt) must be added directly to the pool at least 24 hours before the installation of the equipment.
  • Page 10 Use standard test kits to check water chemistry, and use either a conductivity tester or salt test strip to check saline levels. (Note that most conductivity testers require frequent calibration to ensure accurate readings, failure to calibrate the equipment will result in inaccurate readings.) How to Calculate volume of a pool For a rectangular shaped pool...
  • Page 11: Salt Chart For Correct Maintenance

    The following is a chart to determine the amount of salt required to raise a pool or spa to 5000 ppm SALT CHART FOR CORRECT MAINTENANCE ppm Salt Levels Number of KG's of Salt to Be Added ppm Salt Pool and or spa Volume (litres) 900,000 1,000,000 1,000...
  • Page 12: Tools And Parts Required For Installation

    TOOLS AND PARTS REQUIRED FOR INSTALLATION Your ECOLAB system will include an installation kit comprising of the following items: Description Strainer clear bowl with 20 mesh PVC ball valve Sch. 40 PVC male adaptor Sch. 40 PVC nipple SCH 80...
  • Page 13: Installing Your System - Plumbing

    PLUMBING YOUR SYSTEM Your ECOLAB system can be plumbed using two different methods. Both will work fine, however, the following must be taken into account before making the decision of what method to use. 1. Your ECOLAB system requires a minimum of 75 Lpm of flow through the cell to produce the rated amount of chlorine.
  • Page 14 PRESSURE-DROP PLUMBING METHOD [1] ECOLAB power supply ECOLAB ECOLAB cell NOTES: THE RECTIFIER COOLING LINES MUST BE CONNECTED FROM THE SUCTION SIDE OF THE PUMP AND AFTER THE FILTER. ALWAYS USE FILTERED WATER. IF THERE IS A CONTROLLER PRESENT, THE OUTLET LINE THAT FEEDS THE CONTROLLER PROBES COULD BE CONNECTED TO THE RECTIFIER.
  • Page 15: Electrical

    ELECTRICAL SPECIFICATIONS Each ECOLAB model has very specific wiring requirements based on its line voltage and amperage draw. • Model 2.0 operates at 110 – 120v. A power cord will be supplied out of the power box. Plug this into any standard 110 – 120v outlet. As above, the cord labeled ORP must be plugged into a controller, or a 120v outlet.
  • Page 16: Starting The System

    STARTING THE SYSTEM Once your ECOLAB system has been successfully wired and plumbed, it is ready for use. • Make sure that the valves to and from the cell are in the open position. • Make sure that you have water flowing through the water-cooled heat sink in box 3.
  • Page 17: General Operation

    GENERAL OPERATION Your ECOLAB system operates when power is activated by the main pumps, and from your ORP controller, and will continue to operate for as long as power is applied from those two sources. • The system has an output range of 5-100% of the rated chlorine production, and can be adjusted by turning the black knob of the side of box 1 in a clockwise or anti-clockwise motion.
  • Page 18: Maintenance And Cleaning

    MAINTENANCE AND CLEANING Your ECOLAB systems is designed to operate 24/7 at max power, and will give you years of trouble free use if you follow these basic maintenance and cleaning instructions. • Remember, this system produces sodium hypochlorite “liquid chlorine” from the salt that you have added to the water.