INSTALLATION MANUAL
DOWNFLOW SINGLE AND TWO STAGE ELECTRIC FURNACE WITH:
 FACTORY INSTALLED ELECTRIC HEAT, OR
 NO HEAT MODELS WITH FIELD INSTALLED ELECTRIC HEAT KITS
MODELS: WE30 SERIES
SECTION I: GENERAL
The following list includes important facts and information
regarding the electric furnace and its inclusions.
1. Furnace is rated at 240 volts AC at 60 Hertz
2. Furnace is the same size for all models
3. Four-wire thermostat operation for heating and cooling
4. A/C ready furnaces equipped with blower for A/C or
Heat Pump operation
5. Holding Strap furnished with furnace
6. This furnace is designed for downflow application
7. This furnace must not be operated without furnace door
installed
NOTE: This furnace and its components listed on the
A/C and Heat Pump equipment sticker were listed in
combination as a system by ETL for the United States.
Hamilton Home Products  
LIST OF SECTIONS
1
3
4
5
7
8
LIST OF FIGURES
2
4
4
5
5
5
6
22 - Typical Two Stage Heat Pump/Heating/Cooling T'stat, Furnace 16
6
6
7
7
8
11
11
13
LIST OF TABLES
2
2
2
4
5
9
10
Blower Speed Tap Description
Tap 5 - High Speed - Cooling or Heat Pump Operation
Tap 4 - Med-High Speed - Cooling or Heat Pump Operation
Tap 3 - Medium Speed - Cooling or Heating Operation
Tap 2 - Med-Low Speed - Heating Operation
Tap 1 - Low Speed - Constant Circulation Operation Only.
Tap 1 air circulation is around 200 CFM. This is not enough
air flow for heating, cooling or heat pump operation. If Tap 1
is used for cooling the evaporator will freeze up. If Tap 1 is
used for heating with electric heat the limits will open in a
very short time frame.
DO NOT USE SPEED TAP 1 FOR HEATING OR
COOLING!
SAVE THIS MANUAL FOR FUTURE
REFERENCE
Canal Winchester, OH 43110 
8
12
13
16
17
18
14
14
14
14
15
15
17
17
18
19
20
21
22
10
12
12
13
15
15
16
61MH0037A 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WE30B Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hamilton Home Products WE30B Series

  • Page 1: Table Of Contents

    INSTALLATION MANUAL DOWNFLOW SINGLE AND TWO STAGE ELECTRIC FURNACE WITH:  FACTORY INSTALLED ELECTRIC HEAT, OR  NO HEAT MODELS WITH FIELD INSTALLED ELECTRIC HEAT KITS MODELS: WE30 SERIES LIST OF SECTIONS 1 – General 7 – Line Voltage Wiring 2 –...
  • Page 2: Furnace Dimensions

    Figure 1: Furnace Dimensions Models Input kW With "A" Coil Air Temperature Range - °F 40-100 40-100 40-100 40-100 Max Outlet Air Temperature Blower Size 10 x 9 Max. External Static Pressure In W.C. Thernostat Circuit 24 VAC, 60 HZ, 40 VA Air Handler Cabinet Height 33 Inches Table 1: Electric Furnace Model Specifications...
  • Page 3: Safety

    Safety Requirements SECTION II: SAFETY 1. This electric furnace should be installed in accordance with all national and local building, safety, plumbing, and This is a safety alert symbol. When you see this symbol wastewater codes and requirements; along with all other on labels or in manuals;...
  • Page 4: Downflow Return Air And Clearance Requirements

    Codes SECTION IlI: RETURN AIR AND The furnace must be installed in accordance with the CLEARANCE REQUIREMENTS following codes. Access for servicing is an important factor in the location of  Standard for the Installation of Air Conditioning and any furnace. Provide a minimum of 24 inches in front of the Ventilating Systems (NFPA 90A) furnace for access to the control box, heating elements, and ...
  • Page 5: Downflow Supply Air And Duct Connector Installation

    Provisions shall be made to permit the air in the rooms and the SECTION IV: SUPPLY AIR AND DUCT living spaces to return to the furnace. Failure to comply may CONNECTOR INSTALLATION cause a reduction in the amount of return air available to the Duct Connectors blower, causing reduced air flow resulting in improper heating 90-DCU0-XX Duct Connectors...
  • Page 6: Duct Connector And Floor Base Installations

    Installing the Duct Connector 1. Attach the four (seal strip) foam tape gaskets provided with the duct connector alongside the perimeter of the duct opening to seal the duct connector where it attaches to the top of the duct as shown in Figures 7, 8 and 9. 2.
  • Page 7: Furnace Installation

    SECTION V: FURNACE INSTALLATION Installing the Furnace with a Return Air Grille Frame Assembly Alcove Installation This kit is approved for use in an alcove – heating only installation without an air conditioning coil. The return air grille frame assembly is available in 18” height and 24” height.
  • Page 8: Upflow Configuration

    14. Install a louvered grille in the front of the return air SECTION VI: UPFLOW CONFIGURATION cabinet. This kit is approved for use in an alcove or closet installations with an approved air conditioning coil. The upflow coil cabinets are available in a 28” and 36” height. The upflow configuration requires either a 20”...
  • Page 9: Wiring Requirements - Single Branch Circuit

    Insert the green wire into the ground lug and tighten the furnace and the home's breaker panel. General wire and set screw. breaker sizes are shown in Tables 6 and 7. If sheathed cable is used, refer to NEC National Electrical Code (NFPA 70) or the Dual Circuit Line Wiring Connections: 12kW, 15kW or 20kW Models Canadian Electrical Code, Part I (CSA C22.1) and local codes...
  • Page 10: Wiring Requirements - Dual Branch Circuit

    AIR HANDLER MODELS WE30B4 12 kW Heater Amps ‐ 208/240 CAC 43.88/50 15 kW Heater Amps ‐ 208/240 VAC 54.84/62.5 20 kW Heater Amps ‐ 208/240 VAC Indoor Blower Type Constant Torque Indoor Blower Amps 3.20 Total Electric Heater kW Circuit Number Circuit Load ‐ FLA ‐ 230 VAC 28.20 25.00 44.87 20.83 44.87 41.67 Heater ‐ kW Min. Wire Size (90°C) Minimum Wire Size (75°C) Minimum Wire Size (60°C) Ground Wire Size Max Fuse/Circuit Breaker Amps Table 7: Wiring Requirements – Dual Branch Circuit 12kW, 15kW, and 20kW Two Stage models may have a dual or single power supply. Single power supply will require circuit breaker jumper bar or a jumper wire.
  • Page 11: Control Box Component Locations

    Figure 13: Control Box Component Locations Casing or cabinet must be permanently grounded in accordance with the National Electrical Code or other applicable codes. For personal safety be sure to turn the electrical power “OFF” at the main circuit panel (Home Circuit Breaker Box) and at the control box circuit breakers before attempting any service or maintenance operations.
  • Page 12: Field Installed Heat Kit

    SECTION VIII: FIELD INSTALLED ELECTRIC HEATER KITS This instruction covers the physical installation of the following electric heat kits on the WE30 series models. Refer to Tables 6- To prevent damage, carefully insert the electric heating 8 for electrical specifications. assembly through the rectangular opening in the front of the discharge opening so the heat element support rod is seated Field Installed Electric Heat Kit...
  • Page 13: Control Box Power, Low Voltage Wire Locations

    SECTION IX: THERMOSTAT WIRING AND Thermostat Installation The thermostat heat anticipator must be-set at 0.7 Amps if the CONNECTIONS thermostat has a manual heat anticipator adjustment. This Thermostat Wiring setting should be checked at the time of installation. Thermostat wires connect through side of furnace and should be no smaller than 24 gauge.
  • Page 14: Separate Thermostats, Separate Furnace Wiring Diagram

    If you have separate furnace and air conditioner with separate transformers and your thermostat does not have the “RC” and “RH” terminals it is recommended that you purchase a new thermostat. If the furnace and air conditioner are both When using separate thermostat, a thermostat interlock connected to the thermostat “R”...
  • Page 15: Single Stage Heat / Cool T'stat, With A Two Stage Furnace

    Letter Air Handler Pig Tail Thermostat Condenser Wire Color Description Code Wire Color Connection Connections 24 VAC WHITE HEAT (1st Stage Heat) White W or W1 GREEN Indoor Fan Green YELLOW Cooling - Stage 1 Yellow Y or Y1 Y or Y1 BROWN 24 VAC Common Brown...
  • Page 16: Motor, Blower And Furnace Start Up

    Typical Heat Pump - Heating/Cooling Thermostat Wiring SECTION X: MOTOR, BLOWER AND Connections FURNACE START UP 1. Remove the lower access panel. 2. Remove the control box cover. 3. Install a grommet in the 3/8” dia hole on the right side of the air handler casing to protect the thermostat wire cable.
  • Page 17: Final System Checkout

    6. Turn on all electrical supply circuits to the furnace at the main service (House Circuit Breaker) panel. Figure 23: Constant Torque Motor Terminals Replacing the Blower Motor 1. Turn off all electrical supply circuits to the furnace at Figure 24: Blower Assembly and Blower Deck the main service panel.
  • Page 18: Wiring Diagrams

    SECTION XII: WIRING DIAGRAMS Figure 25: No Electric Heater (0 kW) Wiring Diagram with a Constant Torque blower motor. NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED. IT MUST BE REPLACED WITH TYPE 105°C THERMOPLASTIC OR ITS EQUIVALENT. Hamilton Home Products ...
  • Page 19: Wiring Diagram 10 Kw, W/ C.t. Blower Motor

    Figure 26: 10kW Factory Installed Electric Heat Wiring Diagram with a Constant Torque blower motor. NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED. IT MUST BE REPLACED WITH TYPE 105°C THERMOPLASTIC OR ITS EQUIVALENT. Hamilton Home Products ...
  • Page 20: Wiring Diagram 12 Kw, W/ C.t. Blower Motor

    Figure 27: 12 kW Factory Installed Electric Heat Wiring Diagram with a Constant Torque Blower Motor. NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED. IT MUST BE REPLACED WITH TYPE 105°C THERMOPLASTIC OR ITS EQUIVALENT. Hamilton Home Products ...
  • Page 21: Wiring Diagram 15 Kw W/ C.t. Blower Motor

    Figure 28: 15 kW Factory Installed Two Stage Electric Heat Wiring Diagram with a Constant Torque Blower Motor. NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED. IT MUST BE REPLACED WITH TYPE 105°C THERMOPLASTIC OR ITS EQUIVALENT. Hamilton Home Products ...
  • Page 22: Wiring Diagram 20 Kw W/ C.t. Blower Motor

    Motor. NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED. IT MUST BE REPLACED WITH TYPE 105°C THERMOPLASTIC OR ITS EQUIVALENT. Subject to change without notice Copyright by Hamilton Home Products 2019. ® Hamilton Home Products   Canal Winchester, OH 43110   ...

Table of Contents