Advertisement

Quick Links

English
Series
FOSTER
Installation and Use Manual
FTN Rev. 6 12/2011 – MITECH srl reserves the right to change the information in this document without warning.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FOSTER Series and is the answer not in the manual?

Questions and answers

Summary of Contents for MITECH FOSTER Series

  • Page 1 English Series FOSTER Installation and Use Manual FTN Rev. 6 12/2011 – MITECH srl reserves the right to change the information in this document without warning.
  • Page 2: Table Of Contents

    Index Index   Foster anti-intrusion barrier   Main components   General installation instructions   Bracket mounting options   Mounting on pole with brackets Wall Mounting   Examples of installation   Example of how to protect an independent building   Cables and wiring on terminal board  ...
  • Page 3: Foster Anti-Intrusion Barrier

    Foster anti-intrusion barrier WARNING! - Observe the minimum distances between the Tx and Rx barriers (see table on page 16) - Power the device using the 13.8 Vdc stabilised voltage only - In order for the barrier to work correctly, ensure the power voltage never falls below 12Vcc.
  • Page 4: Main Components

    Main components Main components Item Code Quantity Description Aluminium bar IR cover Plugging caps Optical assemblies From 2 to receiver / transmitter From 2 to Flat cable Motherboard with terminal board and cable/camper input Post supporting brackets From 2 Expansion module to 5 Tamper module Rubber screw cap...
  • Page 5: General Installation Instructions

    General installation instructions 1. After installing the barrier, make sure that it is perfectly closed with the watertight covers supplied. 2. Use the cable clamps supplied to insert the cable in the lower section. 3. Make sure that the path between the sensors is free and that there are no obstacles that could affect the communication between the optical assemblies of the transmitters and receivers (i.e.
  • Page 6: Examples Of Installation

    Examples of installation To be able to monitor the whole perimeter of an area, install the barriers as shown in the figure: Barriers can also be stacked: 1. One-lens barriers 2. Two-lens barriers Foster – Installation and Use Manual Page 6 of 16...
  • Page 7: Example Of How To Protect An Independent Building

    Example of how to protect an independent building The Foster barriers come with crossed beams for maximum protection. For visibility purposes, the beams in this drawing are linear. Barriers Beam transmitted Tx - Tx by barriers Rx - Rx Rx - Rx Tx - Tx Barriers WARNING!
  • Page 8: Cables And Wiring On Terminal Board

    Cables and wiring on terminal board Cables and wiring on terminal board Receivers board ( Receivers board ( ) – Fig. 1 ) – Fig. 1 AND (0 Volt) input Foster – Installation and Use Manual Page 8 of 16...
  • Page 9: Transmitters Board ( Tx ) - Fig

    Transmitters board ( ) – Fig. 2 Foster – Installation and Use Manual Page 9 of 16...
  • Page 10: Aligning The Barriers

    Aligning the barriers Note: The pre-alignment of barriers, which is sufficient for the vast majority of installations, is carried out by the manufacturer during the final testing phase. Initial manual alignment To correctly align the barriers after installation, place the optical assemblies of the transmitters and receivers facing one another, manually moving them to adjust them vertically and horizontally.
  • Page 11: Aligning The Instrumentation

    Aligning the instrumentation Note: Foster barriers are already pre-aligned by the manufacturer. In the event of problems arising during alignment, follow the procedure described below. Aligning the transmitter assembly (transmitter) Reference value: approx 4V (see pages 12 and 13) 1. Connect the tester to one of the main RX expansion boards using the small (red-black) cable supplied.
  • Page 12 4. Manually adjust the optics of the first TX expansion board in order to display the maximum voltage value on the tester, i.e. approx 4 Volts (voltage values beyond 4 Volts are to be considered optimal). Some multimeters might display a voltage that is up to 50% lower.
  • Page 13 3. Connect the tester to the test point of the first RX expansion board in the lower section using the small (red-black) cable supplied. 4. Move jumper MODE on the RX expansion board to position TEST. 5. Manually adjust the optics of the first RX expansion board in order to display the maximum voltage value on the tester, i.e.
  • Page 14: Settings And Programming

    Settings and programming Description of indicators (LEDs) FOSTER RX boards have 6 indicators (LEDs) used for control purposes, which can be enabled by moving the jumper on the two-pin connector marked as LEDs to position ON. It is generally advisable to move the jumper back to position OFF at the end of the testing phase.
  • Page 15: Description Of Characteristics And Jumper Settings

    Description of characteristics and jumper settings FOSTER RX boards can be programmed in different configurations by means of the jumpers. RX BOARD BEAM (preset by manufacturer) Use all the jumpers that correspond to the number of receivers fitted on the barrier (if the barrier has 4 double or single lenses, move jumpers to positions 3 and 4).
  • Page 16: Technical Specifications

    Instruction manual with examples of applications and a small cable for the alignment of instrumentation. Accessories: pole-mounting bracket kit. Full warranty 2 years MITECH S.r.l. Main office: Via Roncaglia, 14 - 20146 Milano - Italy Tel. +39 02.48006383 Fax+39 02.48025620...

Table of Contents