INSTRUCTION MANUAL MOR20L-DHE Please keep this manual safe for future reference! Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please get in touch!
1. BEFORE YOU BEGIN Please read the operating instructions carefully before using your dehumidifier for the first time. 1.1 PRODUCT DESCRIPTION The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity.
Page 4
1.2 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY This appliance is intended to be used by expert or trained users in ● shops, in light industry and on farms, or for commercial use by lay persons. This appliance can be used by children aged from 8 years and above ●...
2. FOR YOUR SAFETY Your safety is the most important thing to us! Please read this manual carefully and fully understand before operating your dehumidifier. OPERATIONAL PRECAUTIONS WARNING- to reduce the risk of fire, electric shock or injury to persons or property: If the supply cord is damaged, it must be replaced by the manufacturer, ●...
Page 6
The appliance shall be stored in a room without continuous operation ● sources (for example: open flames, an operating gas appliance or an operating electric heater). ● The appliance shall be stored so as to prevent mechanical damage from occurring. Do not piece or burn, even after use.
Page 7
2.2.2 Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed. 2.2.3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out.
Page 8
maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: – The charge size is in accordance with the room size within which the refrigerant containing parts are installed;...
3. PRODUCT OVERVIEW FRONT VIEW Control panel Air outlet Air Filter Back shell Front shell Con?nuous drainage Water tank Castors...
Page 10
3.2 FEATURES Powerful moisture removal ● Humidity Monitor shows current air humidity ● Auto mode automatically adjusts humidity levels ● A 12-hour timer to set the time of operation ● ● Effectively removes moisture, dust from the air Low power consumption-energy efficient ●...
3.3 SPECIFICATIONS MODELL MOR20L-DHE 20L/D(30℃, RH80%) Dehumification Capacity Rated Voltage AC220-240V/50Hz Max .rated Input Power 378W/2.0A(30℃, RH80%) Current Noise ≤45dB(A) Water Tank Capacity Maximum Refrigerant R290/60g Charge Net weight 14.5kg M a x i m u m D e s i g n High Side: 3.2MPa,...
Page 12
WARNING nstall the unit in rooms which exceed 4 m². Do not install the unit in a place where inflammable gas may leak NOTE The manufacture may provide other suitable example or may provide additional information about the refrigerant odour. 4.2 OPERATING THE DEVICE SAFELY Check the device after unpacking for any damages or scratches on it.
Page 13
Make sure the Water tank is correctly fitted otherwise the unit will not operate properly. ● The dehumidifier starts up in the mode selected when the unit was last used. ● The dehumidifier starts dehumidifying if the room humidity is 3% higher than the ●...
5. OPERATION ○9 5.1 CONTROL PANEL ○5 ○6 ○3 ○2 ○1 ○7 ○4 ○8 Press to switch the machine on or off. POWER button Mode Button Press to choose Auto and Continuous Drying mode. Timer button Sets a time for the unit to automatically start or stop. Increasing the desired temperature,humidity and timer setting.
Page 15
5.3 SETTINGS Power button In the standby state, press the power button to turn on, the operation indicator lights up and the default fan speed is high, and the default humidity is 50%. In the power-on state, press the power button to turn off, the running indicator light goes off and the compressor stops immediately, and then the fan shut’s down after 30 seconds delay.
6. MAINTENANCE 6.1 DRAINAGE There are two ways of removal collected water produced by the unit. A. Manual draining: Empty water tank by manual. B. Continuous draining: Use gravity to drain condensate water by attaching a drain hose. 6.1.1 EMPTYING THE WATER TANK The water tank built in unit will fill up and shut the unit down once it is full.
Page 17
6.1.2 CONTINUOUS DRAINING For continuous operation or unattended dehumidification, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity. Set the unit in a horizontal surface and stable position. ●...
Page 18
cause damage to the unit. The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated. 1.Remove the filter frame and take off the filter. 2 .Soak the strainer in warm water at about 40 degrees Celsius.
7.TROUBLE SHOOTING 1. FUNCTIONING TEMP. 5°C ≤ Ambient Temp. ≤ 35°C When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops. When 5°C ≤ Ambient temp. ≤ 16°C, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running. 2.BEFORE CALLING FOR SERVICE Before contacting professional service, please review the trouble shooting list that includes common occurrences that are not the result of a defect in...
8. DECOMMISSIONING 1. STORAGE Long-term storage - If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps: Press power button to switch off and unplug the unit.