Chino IR-FA Series Instructions Manual

Communications (options)
Hide thumbs Also See for IR-FA Series:

Advertisement

Quick Links

RX-MEFA0416-P1
IR-FA Series
Communications (Options)
Always keep this instruction with your unit.
Please be sure to deliver this instruction manual with the unit to a final user.

Advertisement

Table of Contents
loading

Summary of Contents for Chino IR-FA Series

  • Page 1 RX-MEFA0416-P1 IR-FA Series Communications (Options) Always keep this instruction with your unit. Please be sure to deliver this instruction manual with the unit to a final user.
  • Page 2: Table Of Contents

    RX-MEFA0416-P1 CONTENTS 1. General ···············································································································1 2. Communications specifications·················································································1 3. Connections···········································································································1 4. Communications procedures ····················································································2 4.1 Basic communications format ·············································································2 4.2 Procedure multi-drop connection·········································································3 4.3 Data expression ································································································3 4.4 Control code ·····································································································3 5. Details of format ····································································································4 5.1 Data commands································································································4 5.1.1 Measured data (1 data: 1 byte, 2 data: 6 bytes) ················································4 5.1.2 Alarm status (Data:2 bytes) ·············································································4...
  • Page 3: General

    Also, for the connection with multiple thermometers, it is necessary to set an address to each thermometer. For the setting of the address, refer to the separate instruction manual IR-FA series Fiber type radiation thermometer (INST.No.INE-378-P ) and IR-FACR series Fiber type radiation thermometer (INST.No.INE-414-P ).
  • Page 4: Communications Procedures

    RX-MEFA0416-P1 4. Communications procedures 4.1 Basic communications format 1) Commands Command Sub-command Data Command (1 character) R: Reading W: Writing A: Answer Sub command Type Data No. (2 characters) (2 characters) Type :PV…Data SV…Parameter Data No.: 01 to 09 2) Positive answer to reading Sub-command Data Reference...
  • Page 5: Procedure Multi-Drop Connection

    RX-MEFA0416-P1 4. Communications procedures 4.2 Procedure for multi-drop connection The followings are the formats for the connection of 2 sets of IR-FA or more (applicable to 1-set connection, too.). 1) Command Command Sub-command Data Reference “** in “ENQ **” shows an instrument address. Make sure to set it by 2 digits (** or *).
  • Page 6: Details Of Format

    RX-MEFA0416-P1 5. Details of format This followings are the descriptions of the "Command", "Sub-command" and "Data". 5.1 Data commands 5.1.1 Measured data data: 1 byte, 2 data: 6 bytes) Reading RPV01 APV01= , data: Data status 0: Normal 1: Overflow 2: Underflow 3: Cramp (For 2-color type IR-FAQH) 4: Hardware abnormal...
  • Page 7: Parameter Settings

    RX-MEFA0416-P1 5. Details of format 5.2 Parameter settings 5.2.1 Alarm setpoint temperature (Data: 4 bytes) Reading RSV02 ASV02= Writing WSV02= Alarm temperature Reference Alarm temperature setting range: 0 to 6280ºC Integer: 4 digits, No decimal digit 5.2.2 Analog output scaling (1 data: 4 bytes, 2 data: 4 bytes) Reading...
  • Page 8: Emissivity (Data: 5 Bytes)

    RX-MEFA0416-P1 5. Details of format 5.2.4 Emissivity (Data: 5 bytes) Reading RSV51 ASV51= Writing WSV51= Emmisivity Reference Emissivity setting range: 1.999 to 0.050 Integer: 1 digit, Decimal: 3 digits 5.2.5 Sample hold/peak hold (Data: 1 byte) Reading RSV53 ASV53= Writing WSV53= Sample hold/peak hold 0: Disable...
  • Page 9: Peak Hold Reset Time (Data: 4 Bytes)

    RX-MEFA0416-P1 5. Details of format 5.2.7 Peak hold reset time (Data: 4 bytes) Reading RSV55 ASV55= Writing WSV55= Reset time Reference Reset time setting range: 0.0 to 99.9 (seconds) Integer: 2 digits, Decimal: 1 digit 5.2.8 Signal modulation mode (Data: 1 byte) Reading RSV61 ASV61=...
  • Page 10: Damping Factor At Peak (Data: 1 Byte)

    RX-MEFA0416-P1 5. Details of format 5.2.10 Damping factor at peak (Data: 1 byte) Reading RSV63 ASV63= Writing WSV63= Damping factor at peak 0: 0ºC/sec 1: 2ºC/sec 2: 5ºC/sec 3: 10ºC/sec 5.2.11 Laser sighting (Data: 1 byte) Reading RSV67 ASV67= Writing WSV67= Laser sighting enable/disab 0: Laser sighting disable...
  • Page 11: Error Codes

    RX-MEFA0416-P1 6. Error codes Error No. Error contents Error answer Error data Error code Framing error 0000 A0001 Overrun error 0000 A0002 Parity error 0000 A0003 0000 Checksum error A0004 Command error **** A0010 (Undefined numbers other than R, W, PV, SV, MV, not specified number) Text format error ****...