RX-MEFA0416-P1 IR-FA Series Communications (Options) Always keep this instruction with your unit. Please be sure to deliver this instruction manual with the unit to a final user.
Also, for the connection with multiple thermometers, it is necessary to set an address to each thermometer. For the setting of the address, refer to the separate instruction manual IR-FA series Fiber type radiation thermometer (INST.No.INE-378-P ) and IR-FACR series Fiber type radiation thermometer (INST.No.INE-414-P ).
RX-MEFA0416-P1 4. Communications procedures 4.1 Basic communications format 1) Commands Command Sub-command Data Command (1 character) R: Reading W: Writing A: Answer Sub command Type Data No. (2 characters) (2 characters) Type :PV…Data SV…Parameter Data No.: 01 to 09 2) Positive answer to reading Sub-command Data Reference...
RX-MEFA0416-P1 4. Communications procedures 4.2 Procedure for multi-drop connection The followings are the formats for the connection of 2 sets of IR-FA or more (applicable to 1-set connection, too.). 1) Command Command Sub-command Data Reference “** in “ENQ **” shows an instrument address. Make sure to set it by 2 digits (** or *).
RX-MEFA0416-P1 5. Details of format This followings are the descriptions of the "Command", "Sub-command" and "Data". 5.1 Data commands 5.1.1 Measured data data: 1 byte, 2 data: 6 bytes) Reading RPV01 APV01= , data: Data status 0: Normal 1: Overflow 2: Underflow 3: Cramp (For 2-color type IR-FAQH) 4: Hardware abnormal...