Page 1
Personal Humidifier USER GUIDE PP-19-1 REV. 15...
Page 2
Please contact your care provider, licensed distributor, or Perma Pure if you have trouble setting up or using the O2asis device. Should you need to contact Perma Pure directly, please use the O2asis™ is a registered trademark of Perma Pure, LLC.
CONTENTS Included with the System ....... . 6 Regular Cleaning ........18 Device Overview and Features .
Page 4
This could damage the device or cause air leaks. The O2asis Humidifier is a device intended to add moisture to breathing gases before they reach • Always route the power cord in a way that will avoid anyone tripping or anything otherwise the patient to aid in the comfort of oxygen therapy.
Page 5
Contact your the parts and accessories used to connect to the patient before use. care provider, licensed distributor, or O2asis Customer Service for repair or replacement. • The included cannula is validated for use with this device.
NOTE: If any of the items listed above are missing or damaged, please contact Do not use if package is open or Instructions for Use your care provider, licensed distributor, or O2asis Customer Service. damaged DEVICE OVERVIEW AND FEATURES Non sterile...
FEATURES asis Base Unit — The base of the humidifier that includes the heat con- trol buttons and the connection to the power plug. asis Water Well Consumable Cartridge — The top cartridge that in- cludes the water reservoir and heated line.
SAFETY FEATURES SETTING UP THE DEVICE Place the device on a firm, flat surface within easy reach of where you will use The O asis Humidifier has been designed with the following safety features to Do not place the device near any sources of heating or cooling such as limit temperature, power currents, and to cut off power of the device to ensure fire places, radiators, air conditioners, or forced air vents.
Do not overfill the water reservoir. Use only the included Water Fill Pump to fill the device. Warning: The Water Fill Pump is only intended for use with the O2asis Obtain a one-gallon bottle or jug of distilled water (available at many Humidifier.
Page 10
The first time using the Water Fill Pump: Slowly push down on the water fill pump handle 5 times to fill the Water Well. As needed, remove Water Well to visually check water Hold the pump collar in one hand. Use the other hand level, see section Checking for an empty Water Well, to twist pump head COUNTER-CLOCKWISE.
Immediately discontinue use and replace if damaged To connect the device to AC power, complete the following steps: Contact your care provider, licensed distributor, or O2asis Customer Service for replacement. Ensure the blue latch is closed.
Note: Color-Coded Port Connections for the Oxygen Hose heated line The table below includes an image of the green color-coded O2asis Humidifier Oxygen Connection Port. Port Label and an image of the Color-Coded Port Connections Position cannula on face as directed by your care provider.
USE WITHOUT ELECTRICAL POWER Setup and use for pediatric patients are consistent with all other instructions The O2asis Humidifier will continue to provide humidity even when disconnect- within this manual, except as follows: ed from the power supply. For use without power, simply unplug the power...
REPLACING THE WATER WELL To replace the Water Well consumable cartridge, complete the following steps: CONSUMABLE CARTRIDGE Unplug the power adapter cord from the latch side of the device. What You Will Need Unplug the oxygen source line from the oxygen connector.
Page 16
Lift the latch side of the Water Well consumable Swing the base latch up and snap it onto the cartridge and rotate out of the base. cartridge to lock it in place. Water Well Do not Reverse side of remove water Water Well bladder Fill the Water Well using the Water Fill Pump and distilled water as...
CHECKING FOR AN EMPTY WATER WELL Warning: You must replace the Water Well consumable cartridge every 30 days to ensure device safety and performance. Failure to replace the car- tridge can result in degraded device performance and risk of serious patient Remove connections: injury.
CLEANING AND DISINFECTION Check Water in Water Well: If low or empty, refill water well. Regular Cleaning Clean the device periodically and when dirt or debris is visible on the out- side of the device. To clean the device base, disposable cartridge, or water fill pump, use a lint free cloth dampened with water and a few drops of dish soap.
General Purpose Disinfectant under Product Code (LRJ). Allow the device to air dry completely. If Power Supply is exposed to the patient, disconnect from the O2asis device and wall. Repeat steps 4 through 6, and let thoroughly dry. asis User Guide...
MOVING THE DEVICE TECHNICAL SPECIFICATIONS To move the device to a new location, it is recommended that the power Physical adapter plug be disconnected from the humidifier base. When moving with the device, make sure to secure the unit and route the tubing such that you will not Dimensions .
Electrical Standards Classification The device shall only receive power from the included Globtek GMTM46402- • This device is an US FDA cleared Class II medical device. 3612 power supply. • This device is considered an IEC Class II, continuous operation, ordinary AC Power Input .
Warning: The O asis Humidifier should not be used adjacent to or stacked Medium with other equipment. If adjacent or stacked use is necessary, the O2asis Humidifier should be observed to verify normal operation. If operation is High not normal, the O asis Humidifier or the other equipment should be moved.
± 2, 4, 8, 15kV air The O2asis Humidifier is intended for use in the electromagnetic environment specified be- 61000-4-2 low. The user of the O2asis Humidifier should assure that it is used in such an environment. Electrical fast tran- ± 2 kV for power...
IEC 61000-4-3 3 V/m or hospital settings. care provider, licensed distributor, or O2asis to 80 MHz to 10 V/m return the device. 2.5 GHz asis User Guide...
Page 26
O2asis to return the device. or O2asis to return the device. er or cooler. The air flow The connection...
Page 27
If any of these problems occur again after you perform all suggested actions, dry. with regular or such that it is not providing comfort anymore, contact the care provider, licensed distributor, or O2asis for customer service. filtered tap water. please purchase a new Water Well to restore full comfort.
Page 28
1001 New Hampshire Ave Lakewood, NJ 08701 USA Toll Free: 1-800-337-3762 www.o2asishumidifier.com...
Need help?
Do you have a question about the O2asis and is the answer not in the manual?