BOILER CONDENSATE PUMP - INSTALLATION INSTRUCTIONS
Product Keyword: BCONDP
INTRODUCTION
Your BOSS Condensate Pump is designed as an automatic condensate removal pump for pumping away
room temperature condensate from domestic and light commercial condensing boilers. The pump is controlled
by a float/switch mechanism which turns the pump on to discharge the water when approximately 60mm of
condensate collects in a tank. The pump automatically switches off when the tank drains to approximately
30mm.
The BOSS Condensate Pump you have purchased is a high quality product that has been engineered to give
you long and trouble-free service.
This pump is carefully packaged, inspected and tested to ensure safe operation and delivery. When you
receive the pump, examine it carefully to determine there are no broken or damaged parts that may have
occurred during shipment. If damage has occurred, please contact your supplier. They will assist you in
replacement or repair, if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THE
BCONDP PUMP. KNOW THE PUMP APPLICATION, LIMITATIONS AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN
INSTRUCTIONS FOR FUTURE REFERENCE. INSTALLATION AND CONNECTIONS ARE TO BE MADE BY
A QUALIFIED PERSON.
SAFETY GUIDELINES
DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS PETROL, FUEL OIL,
KEROSENE, ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES. PUMP SHOULD BE USED WITH
LIQUIDS COMPATIBLE WITH PUMP COMPONENT MATERIALS.
DO NOT HANDLE PUMP WITH WET HANDS OR WHEN STANDING ON WET OR DAMP SURFACE, OR IN
WATER. THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND/OR GROUNDING TYPE
ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRICAL SHOCK, BE CERTAIN THAT IT IS
CONNECTED TO A PERMANENT EARTH.
FOR INSTALLATIONS WHERE PROPERTY DAMAGE AND/OR PERSONAL INJURY MIGHT RESULT
FROM AN INOPERATIVE OR LEAKING PUMP DUE TO POWER CUTS, DISCHARGE LINE BLOCKAGE,
OR ANY OTHER REASON, A BACKUP SYSTEM(S) AND/OR ALARM SHOULD BE USED.
SUPPORT PUMP AND PIPING WHEN ASSEMBLING AND WHEN INSTALLED. FAILURE TO DO SO MAY
CAUSE PIPING TO BREAK, PUMP TO FAIL, MOTOR BEARING FAILURES, ETC.
THE PUMP IS DESIGNED TO TAKE CONDENSATE ONLY, UNDER NO CIRCUMSTANCES SHOULD HIGH
TEMPERATURE PRESSURE RELIEF BE DISCHARGED INTO THE PUMP – (ALTERNATIVE THE
"BCONDPHWHOSE" PUMP IS SPECIFICALLY DESIGNED FOR THIS APPLICATION)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BCONDP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Boss BCONDP

  • Page 1 The pump automatically switches off when the tank drains to approximately 30mm. The BOSS Condensate Pump you have purchased is a high quality product that has been engineered to give you long and trouble-free service.
  • Page 2 INSTALLATION 1. Mounting the pump: The tank has two slots provided to mount the unit on a vertical surface such as an adjacent wall. The slots are located on the ends of the tank (Fig. 1). Pump must be level and the inlet must be below the boiler drain point.
  • Page 3 ELECTRICAL CONNECTIONS 1. Shut off electrical power at fuse box before making any connections. All wiring must comply with local codes. 2. Line voltage: Connect pump to voltage specified on label located on pump. Wiring is as follows: Live - Brown Neutral - Blue Earth - Yellow/Green 3.