IMPORTANT SAFEGUARDS CAUTION!!! WARNING!!! Read instruction manual before using. 1. To provide continued protection against risk of electric shock, connect to properly grounded outlets only. 2. Do not immerse in water. 3. Hot surface! Avoid contact! 4. Shock Hazard. To provide continued protection against electric shock, disconnect from power supply when not in use.
Page 3
10. Children should be supervised to ensure that they do not play with the appliance. 11. The soldering iron and desoldering iron are only to be used with the power supply unit provided with the appliance. 12. If the supply cord is damaged, it must be replaced by the manufacturer, a service agent, or similarly qualified persons.
Page 4
16. To ensure personal safety, please turn off the power switch after work is completed. When not in use for an extended period, please unplug the power cord. 17. Do not install nozzle when the hot air gun is turned on. The heat pipe and nozzle must be cooled before installing another nozzle.
Page 5
SPECIFICATION & APPLICATIONS Model Number USS-SS00002 Control Unit Dimensions L150*W136*H100mm±5mm Hot Air Rework Station Air flow Type Brushless Fan with Smooth Air Delivery Air Volume ≤120L/Min Temperature Range 100℃〜480℃/212℉〜896℉ Display Soldering Station Temperature Range 200℃〜480℃/392℉〜896℉ Display Tip to Ground Resistance <2Ohms...
II.OPERATION Hot Air Rework Station 1. Set the rework station correctly. Install the hot air gun holder to the left side of the station, and place the hot air gun onto the holder. 2. Install the required nozzle (Use of large-diameter nozzles is recommended), and connect the station's power cord to an electrical outlet.
Page 8
program tracks and compensates the hot air gun's actual temperature every millisecond. The hot air gun is now in the high-precision thermostatic state. 4. When the operation is complete, place the hot air gun back to the holder. Turn OFF the power switch (hot air), and the operation indicator light of the hot air gun turns OFF.
Page 9
bottom-right corner of the soldering station's display) turns ON. The indicator light stays ON when station heating, blinks rapidly when the temperature is stabilized, turns OFF when station cooling. Begin with the operation when the soldering station's operation indicator light blinks rapidly to indicate temperature stabilization.
Page 10
Digital Temperature Calibration Temperature discrepancies may occur due to the change in the environment's temperature or due to the replacement of the heating element and other components. You can correct the discrepancies with this function. The temperature calibration function can help improve work efficiency and prolong the lifespan of the soldering iron.
Page 11
2. Press the hot air (soldering station) temperature increase or decrease button to enter the measured temperature value. 3. Press and hold both the hot air rework station(soldering station) temperature increase and decrease buttons to confirm. The system automatically calibrates the temperature and exits the calibration interface.
Page 12
3. Press the soldering station temperature increase or decrease button to select either the Celsius or Fahrenheit display mode. Once done, press the hot air rework station temperature increase button to confirm setting and exit the setting interface. Zero-Air Protection When the hot air gun stops putting out air abnormally during an operation, the system will automatically cut off the power to the heating element.
Page 13
Sleep Mode (Soldering Station) The station self-detects its operating status automatically. When the iron is not in use and stayed static for longer than approximately 10 minutes, the soldering iron will cool to 200°C/392° automatically to enter sleep mode. This function prevents the iron tip from oxidizing effectively, extends the lifespan of the soldering iron tip, and conserves energy.
Page 14
3. Stop operating for approximately 6 seconds, the system will then save the data and exit the setting interface. To start up the iron from sleep mode: a. Shake the iron a few times. b. Press any button on the soldering station. c.
Page 15
3. Stop operating for approximately 6 seconds, and the system will automatically save the setting and exit the setting interface.
III. MAINTENANCE & PRECAUTIONS Hot Air Rework Station 1. Keep the air outlet clear and free of blockages at all times. 2. The installation of the hot air nozzles MUST be carried out ONLY when the steel pipe and nozzles have cooled. Install the nozzle correctly. DO NOT install the nozzle with brute force, pull the edge of the nozzle with tweezers, or over-tighten the screws.
Page 17
while. NOTE: The station's hot air gun and soldering iron’s handles use high-strength stainless steel tubes. The station goes through 4 or more testing, inspection, and calibration procedures before rolling off the assembly line. The steel tube may exhibit light bronze color as a result of our quality control efforts.
Page 18
solder onto the solder ing ir on tip while r ubbing it until the tip is completely coated with solder . If the tip is too sever ely oxidized beyond cleaning, r eplace it with a new one. 2. DO NOT use metal files to remove the oxidization on the soldering iron tip.
IV. TROUBLESHOOTING 1. S-E – This is an indication that the station's sensor module is faulty. You need to replace the heating element (the heating element and the sensor modules). Or it may be that the soldering iron has not been connected (Turn OFF the power, connect the soldering iron, then turn ON the station again.) 2.
Page 20
Contact Feel free to visit our website: www.ussolid.com You can email us at service@ussolid.com You can call one of our friendly customer service representative at +1(800) 209-4177...
Need help?
Do you have a question about the USS-SS00002 and is the answer not in the manual?
Questions and answers