Warnings:
 Do not use to remove ice dams that have already formed or clear the roof of ice and snow.
 Do not use on roofs with wooden shingles, rubber roofs or composite (tar and gravel) roofs.
 Do not use on wooden gutters or downspouts.
 Do not use for any other purposes, such as melting snow or ice on sidewalks or pipes freezing
protection.

Included Material

Roof and Gutter De-icing
Heating Cable

Tools Required

Receipt, Storage and Transportation

Receipt
Compare the materials against the invoice and check to verify the proper materials have been received. The
cable's model number is printed on its label.
Review your design documents and check the received materials against the lists to verify all the needed
materials were received.
Inspect the heating cable and accessories to ensure there is no in-transit damage.
Storage
Cables and system components should be stored in a clean, dry area. The storage temperature range is
-18°C to 60°C (0°F to 140°F).
Transportation
Transport heating cables and connection components at a clean and dry location.
During transportation, any contact with chemicals and petrochemical products must be effectively avoided.
It must be ensured that the heating cables are protected against mechanical damage during transportation.

Before installation

If the heating cable is stiff (due to being cold), first uncoil it and then power it with a 120V receptacle until it is
warm and pliable, then unplug the power before attaching it to the roof and gutter.
Cable spacer
Roof clip
5
Caution label