Page 1
STAINLESS STEEL CRITI-CLEAN ORIGINAL FAN FILTER UNITS READ COMPLETELY AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE -These instructions cover fan filter unit models: - SSLFHFD-FP (Standard) - SSLFHFD-FP-MEA (Motor/Electronincs Accessible) DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL...
Page 2
FPH-RP37 FPH 208/240/24VAC transformer FPH-RP38 FPH 277/24VAC transformer FPH-RP39 FPH Network power control circuit board DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL 2 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 3
This unit is to be used only as intended by the manufacturer. If you have any questions regarding the use, installation, or operation of this unit, contact the manufacturer: AJ Manufacturing Co., Inc. 8701 Elmwood Ave, #400 Kansas City, MO 64132...
Leak test the fan unit and filter per local codes and building procedures. □ Install the perforated face screen. □ Verify airlow with a flow hood. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL 4 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
SSLFHFD-FP-120 --- 120VAC SUPPLY Line voltage wiring knockouts SSLFHFD-FP-208/240 --- Duel rated 208 or 240VAC SUPPLY SSLFHFD-FP-277 --- 277VAC SUPPLY Step 5 -- Blow out / clean entire duct system leading to unit to remove construction NOTE: FOR DUCTED INSTALLATIONS, IT IS RECOMMENDED debris.
Page 6
This will cause the motor to shut down. Continual running of the motor backward may result in reduced reliability of the EC motor. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL 6 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 7
Filter should be completely dry before reinstalling into unit. Step 5 -- Using the driver, re-secure the cover with the screw. Pre-filter access DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL 7 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 8
Step 10 -- Raise the face frame back into place, reattach the safety chains, and secure 1/4-turn fasteners. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL 8 29 CHKD PRODUCT DRAWING NAME 1:12 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 9
STAINLESS STEEL CRITI-CLEAN ORIGINAL Removal and Installation of the Variable Speed Motor (SSLFHFD-FP) FAN FILTER UNITS WARNING! Disconnect the unit from the electrical power source before attempting to service the unit. Duct Connector Step 1 -- Turn the unit off with the switch located on the face of the unit.
Page 10
Step 11 -- Reverse above steps to reassemble the motor/fan/ring assembly into the unit. The fan collar Face Frame should be even with the end of the motor shaft. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 10 29 CHKD PRODUCT DRAWING NAME 1:12 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 11
Step 6 -- Reverse above steps to replace electrical components and to replace panel. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 11 29 CHKD PRODUCT DRAWING NAME 1:12 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 12
Step 11 -- Reverse above steps to replace electrical components and to replace panels. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 12 29 CHKD PRODUCT DRAWING NAME 1:12 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
- RED --FILTER DIRTY (OPTIONAL) SETPOINT CONTROL CALIBRATION CONTROL ON/OFF SWITCH FUSE FACE FRAME ON FACE FRAME REMOVED DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 13 29 CHKD PRODUCT DRAWING NAME 1:15 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 14
MAIN POWER SWITCH RESETTABLE FUSE DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 14 29 CHKD PRODUCT DRAWING NAME 1:12 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 15
1/2" barb fitting PAO Challenge System blows oil into airstream SECTION for maximum mixing DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 15 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 16
OSHPD Certification is Pending STACKUP DETAIL Temporary Record # 21TMP-006268 (All hanging components - supplied by others) DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 16 29 CHKD PRODUCT DRAWING NAME 1:12 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 17
Connect wires like to like at each end of the extension leads. Retest unit to verify operation. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 17 29 CHKD PRODUCT DRAWING NAME SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 18
Power is supplied to controller by a wall AC adapter supplied with controller. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 18 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 19
L. JP420: 0-20mA or 4-20mA signal format selector M. JFBS: TACH or Analog 2 feedback signal selector N. Aux Board Port DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 19 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
2 - 2 = 0 SW1-2 ON 64+32+16+2 = 114 *See page 23 for more examples DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 20 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 21
VSEL = DC filtered, unregulated, ~33VDC - Controling airflow by room pressure or particle counter DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 21 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 22
RED WIRE FROM SENSOR TO INP2 BLACK WIRE FROM SENSOR TO 5V WHITE WIRE FROM SENSOR TO COM DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 22 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 23
- Powered by ~33VDC supply If 10V output Shunt on V.RFU JVS-2 shunted and center pin DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 23 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 24
- Powered by ~33VDC supply Shunt on V.RFU and center pin Shunt Middle and 20mA Shunt JP420 DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 24 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 25
Conduct smoke or photometer test on HEPA filter and gel seal. If fail seal or replace the HEPA filter as necessary. DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 25 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
LINE VOLTAGE Green 14awg 24 VAC Main Power Switch Black 14awg White 14awg Resettable fuse DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 26 29 CHKD PRODUCT DRAWING NAME 1:1.2 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 27
24 VAC Main Power Green 14awg Switch Black 14awg White 14awg Resettable fuse Safety Switch DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 27 29 CHKD PRODUCT DRAWING NAME 1:1.2 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Page 28
18 - 16 = 2 SW1-5 ON 2 - 2 = 0 SW1-2 ON 64+32+16+2 = 114 DRAWN CATEGORY REV # F BRS/SLG CRITI-CLEAN ORIGINAL INSTALLATION MANUAL SHT 28 29 CHKD PRODUCT DRAWING NAME 1:10 SSLFHFD-FP, SSLFHFD-FP-MEA APRVD SIZE DO NOT 01/24/22 SCALE...
Buyer’s purchase. CHARGES ACCRUED AGAINST SELLER’S ACCOUNT WITHOUT PRIOR APPROVAL OF SELLER WILL NOT BE PAID BY SELLER. If, after notifying AJ of defect, Buyer returns goods to AJ for repair and AJ determines that it has not breached the foregoing warranty, the Buyer will be assessed AJ regular reconditioning charges.
Need help?
Do you have a question about the SSLFHFD-FP and is the answer not in the manual?
Questions and answers