Ekinex EK-AM1-TP Manual

Advertisement

Quick Links

KNX bus power supply 1280 mA with 30
Vdc auxiliary output
Product code: EK-AM1-TP
S
TP
KNX device with function of power supply for a bus line
with auxiliary output. It has to be used in KNX installations
for control of homes and buildings.
Description
The ekinex
power supply EK-AM1-TP is a KNX device
®
for rail mounting which produces and monitors the 30 Vdc
voltage required to operate the bus system. It has a 30
Vdc additional output, which can be used as a SELV (sa-
fety extra low voltage) auxiliary power for bus devices.
The device has an integrated choke which provides the
decoupling between the power supply and the information
on the bus line. On a KNX bus line can be connected up
to 256 KNX bus devices. The output is protected from
overload, short circuit and overvoltage. The total current
absorbed by the two outputs (KNX bus and auxiliary) can-
not exceed 1280 mA. The device can support short inter-
ruptions of the mains voltage (max 200 ms at full load).
Functions
• 30 Vdc SELV power supply for a KNX bus line with max
256 connected devices (depending on the current con-
sumption of each device)
• Auxiliary power supply 30 Vdc
• Reset of the connected bus line with a dedicated pu-
shbutton
• LED indicators for normal operation, bus reset and bus
overload
• Protections: overload, short circuit, overvoltage
Datasheet STEKAM1TP_EN
1
• Cooling by free air convection
Main characteristics
• Housing in plastic material
• Mounting on 35 mm rail (according to EN 60715)
• Protection degree IP20 (installed device)
• Isolation class I
• Safety class II
• Overvoltage cathegory III (according to EN 61558, EN
50178, altitude up to 2000 m. s.l.m.)
• 4 modular units (1 UM = 18 mm)
• Dimensions 72 x 90 x 70 mm (WxHxD)
• Weight: 296 g
Environmental conditions
• Operating temperature: - 30 ~ + 70°C
• Storage temperature: - 40 ~ + 85°C
• Working humidity: 20 ~ 95% RH not condensing
• Storage humidity: 10 ~ 95% RH not condensing
Technical data
Power supply
• Mains voltage range 180 ~ 264 Vac, 176 ~ 280 Vdc
• Frequency range 47 ~ 63 Hz
• Power consumption 38.4 W
• Input AC current (typical) 0.5 A @ 230 Vac
• Inrush current (typical): cold start 60 A (t
measured at 50% l
) @ 230 Vac
peak
• Leakage current: < 1 mA @ 240 Vac
Outputs
• Bus line voltage: 30 Vdc SELV
• Auxiliary voltage: 30 Vdc SELV
• Rated current (total outputs): 1280 mA
• Short circuit current: 2.8 A
• Setup, rise time: 1000 ms, 50 ms @ 230 Vac at full load
• Ripple & noise (max): 100 mVp-p (*)
• AC mains failure back-up time (typical): 200 ms @ 230
Vac at full load
• Bus line connection: KNX terminal block (black/red) in-
cluded in delivery
• Auxiliary output connection: dedicated screw terminal
block
(*) Note: Ripple & noise are measured al 20 MHz of bandwidth
by using a 12'' twisted pair-wire terminated with a 0,1 μF and 47
μF parallel capacitor. The measure is done before the decoupling
choke.
Protections
• Overload: 205 ~ 235% rated output power. Protection
type: constant current limiting, recovers automatically
after fault condition is removed
• Overvoltage: 33 ~ 35 V. Protection type : Hiccup mode,
recovers automatically after fault condition is removed
Safety and EMC
• Safety standards: EN 61558-1, EN 61558-2-16; EN
50491-3
• Withstand voltage I/P-O/P: 4, 2KVAC I/P-FG: 2KVAC
• Isolation resistance: I/P-O/P, I/P-FG: 100 MΩ @ 500 Vdc
@ 25 °C @ 70% RH
• EMC emission: compliance to BS EN 50491-5-2, -5-3;
BS EN 61000-3-2, -3-3
• EMC immunity: compliance to BS EN 50491-5-2, -5-3;
BS EN 61000-4-2, 3, 4, 5, 6, 8, 11.
=1200 µs
width

Advertisement

loading
Need help?

Need help?

Do you have a question about the EK-AM1-TP and is the answer not in the manual?

Questions and answers

Summary of Contents for Ekinex EK-AM1-TP

  • Page 1 12’’ twisted pair-wire terminated with a 0,1 μF and 47 μF parallel capacitor. The measure is done before the decoupling The ekinex power supply EK-AM1-TP is a KNX device ® choke. for rail mounting which produces and monitors the 30 Vdc voltage required to operate the bus system.
  • Page 2 At the same bus line can be connected not more than two power supplies. A second power supply may be necessa- ry when the installation in distribution boards requires a particular concentration of the bus devices (tipically more than 30 units installed within 10 m). In this case a po- wer supply has to be installed near the group of devices.
  • Page 3: Electrical Connections

    Before removing the device, be sure the inputs have been • color codification: red = + (positive) bus conductor, disconnected and the bus terminal has been extracted black = - (negative) bus conductor from its slot. Use a screwdriver to slide down the locking device and remove the device from the rail.
  • Page 4: Maintenance

    Documentation This datasheet refers to the release A1.0 of the ekinex ® device EK-AM1-TP and it is available for download at www.ekinex.com as a PDF (Portable Data Format) file.
  • Page 5 EKINEX technical support in case of malfunctio- ning of the device • KNX and ETS are registered trademarks of KNX ® ® Association cvba, Brussels © EKINEX S.p.A. The company reserves the right to make changes to this documentation without notice.
  • Page 6 • the maximum length of a line segment is 350 m, mea- • It is possible to connect two EK-AM1-TP in parallel with sured along the line between the power supply and the the following conditions: two chokes installed in one furthest device bus;...
  • Page 7 Annex 3 - Block diagram Annex 4 - Characteristics Derating curve Static characteristics...