COLUMBIA SPECIFICATIONS
SANI-LAV Sensor Faucets
Wall Mounted AC and Battery Powered
Meets ANSI/ASME A112.18.1 M-1989

Operation

1. A continuous, invisible beam is emitted from the sensor.
2. The faucet is activated by placing hands under the spout within the effective
range of the beam. Water starts to flow immediately for as long as the user's
hands remain in the sensor range.
3. When hands are removed, the water flow stops. The sensor will automatically
reset and be ready for the next user.
4. In the battery powered version, a flashing red light will indicate a low battery
condition.

Specifications

Faucet Construction
Control Circuit
– Auto. Time-out
– Line Purge (request only)
– Scrub Mode Delay (request only) 60, 120, 180 seconds
– Sensor Range
– Shut-off Delay
Control Cable
Solenoid Valve
– Wattage: 0.4W (idle), 5W (in use)
– Operating Pressure: 5 psi to 125 psi
Flow Control
AC Mode
Power Adapter
– Standard Plug-in
– (UL/CSA)
Power Cable
– Optional Multi-Unit Adapter
– (UL/CSA)
Battery Mode
Battery Powered Models
Battery Service Life
Package Includes
(1) Faucet with electronic sensor
(1) Control box w/6V DC solenoid
(1) 12V DC plug-in power adaptor (H-6700C, -DC, -LR and -LRDC only)
(1) In-line filter with clean-out trap
(1) 18" Flex, S.S. supply tube, 3/8"(1) 6" Gooseneck Spout
(1) Mounting hardware
(1) 2.0 GPM Flow Control(4) AA Alkaline batteries (HB-6700C, -DC, -LR, -LRDC only)
(1) Battery holder (HB-6700C, -DC, -LR, -LRDC only)
Dimensions
– Base Width (Outside Measurement)
– Base Depth
– Faucet Height (Aerator to Base)
– Faucet Height Overall
– Depth (Center of Aerator to Center of Faucet Base)
– Mounting Bolt Length
– Mounting Bolt Pattern
Optional Variations and Accessories
– 0.35, 0.5, 1.5, 2.2 GPM Laminar Flow
– HC-010 Multi-Unit Voltage Adapter (AC Powered Only) - 8 units
– HC-0104 Multi-Unit Voltage Adapter (AC Powered Only) - 4 units
– HC-001 Mixing/Check Valve (Mechanical)
– HBL-04-LR Thermostatic Mixing Valve with Checks (Low Lead)
– 8" deep Gooseneck and 6" or 8" Swing Swing SpoutModel
Solid brass, chrome plated
Solid state, AC or battery, switchable
Preset at 20 seconds and adjustable to 10,
30, or 60 seconds
2 minute run every 12 hours
or 24 hours
Preset and adjustable
Presets and adjustable from 1-8 seconds
Armored, vandal resistant
6V DC, normally closed
2.0 or 0.5 GPM, Laminar Flow Control
Input AC 120V 60 Hz or 220V
Output DC 12V, 0.8A/Class 2
Armored, vandal resistant
Serves up to 8 faucets
Input AC 120V, Output DC 12V, 3A
(4) AA Alkaline Batteries
400,000 on/off cycles, up to 4 years
2-1/4"
2-1/2"
8-3/4"
12-3/4"
5-3/8"
1-7/16"
Single-hole mount
Model
Sensor Type
Flow-Rate
ES2RL
AC Powered
Standard 2.0 GPM
ES2RL-0.5
AC Powered
Low-Flow 0.5 GPM
Model
Sensor Type
Flow-Rate
ESB2RL
Battery Powered
Standard 2.0 GPM
ESB2RL-0.5
Battery Powered
Low-Flow 0.5 GPM
800.626.2117
columbiasinks.com info@columbiasinks.com
S E N S O R FA U C E T S
5
ADA Compliant
©2021 Columbia Products