Instructions for the installer
Avoid use of adapters and shunts as these could cause overheating and a risk of burns.
If a fixed connection is being used, fit the power line with an omnipolar circuit breaker with a contact
opening gap equal to or greater than 3 mm, in an easily accessible position close to the appliance.
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance.
APPLIANCE
POSSIBLE CONNECTION
TYPE
(CM)
220
• Use H05V2V2-F cables withstanding a temperature of at least 90°C.
• The values indicated above refer to the cross-section of the internal conductor.
• The tightening torque of the screws of the terminal supply wires must be 1.5 - 2 Nm.
• The aforementioned power cables are sized taking into account the coincidence factor (in compliance
with standard EN 60335-2-6).

11.5 Positioning the skirt (on some models only)

The skirt must always be positioned and secured correctly on
the appliance.
1 Loosen the 4 screws (A) on the back of the worktop (2 for
each side).
2 Place the skirt above the worktop, taking care to align the
skirt's slots (B) with the screws (A).
3 Secure the skirt to the worktop by tightening screws (A).

11.6 Positioning and levelling the appliance

After making the electrical and/or gas connections, level the
appliance on the floor by means of its four adjustable feet. The
appliance must be properly levelled to ensure stability.
TYPES
-
240
V
1N~
CABLE TYPE
(if not present)
3-pole
3 x 1.5 mm²
appliance side
H05V2V2-F
63