Download Print this page

HIKVISION DS-K1A802A Series Quick Start Manual page 2

Fingerprint time attendance terminal
Hide thumbs Also See for DS-K1A802A Series:

Advertisement

3
Basic Operation
1
Activation
Activating via Device
Power on and wire the network cable after installation.
You should activate the device before the first login.
After powering on, the interface will be displayed as follows.
You can create the device password and confirm the
password to activate.
The default values of the terminal are as follows:
• The default IP address: 192.0.0.64
• The default port No.: 8000
• The default user name: admin
STRONG PASSWORD RECOMMENDED
We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case
letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you
reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your
2
Parameters Configuration
Configure the shift schedule by department or by individual.
Schedule Shift by Department Flow: Add User (Select department when adding new user.) - Department Management - Shift Management - Add Holiday - Shift Schedule Management (Schedule Shift by Department)
Schedule Shift by Individual Flow: Add User - Shift Management - Add Holiday - Shift Schedule Management (Schedule Shift by Individual)
Attendance Status: Set attendance status as check in, check out, break out, break in, overtime in, or overtime out.
Add User: Edit the ID No. and the user name. Press the OK key to confirm. Enter the card No., register the fingerprint, set the password, select the department, select the user role and select the authentication mode. Save the parameters to confirm adding. The employee ID should be unique, should be
between 1 and 99999999, and should not start with 0.
Edit Department: Select the department in the department list and select "Edit". Edit the department name, the shift type and the shift name. Save the parameters to confirm editing.
Shift Management:
Normal Shift:Enter the Normal (Normal Shift) interface under the Shift Management menu. Configure the shift rule and the normal shift. Save the parameters to confirm editing.
Man-Hour Shift: Enter the Man-Hour (Man-Hour Shift) interface under the Shift Management menu. Configure the man-hour parameters and save the parameters.
Add Holiday: Enter the New (Add New Holiday) interface under the Holiday menu. Enter the holiday No., the holiday name, the holiday start date and the holiday end date. Save the parameters to confirm configuration.
Shift Schedule Management:
Schedule Shift by Department: Select a department to configure in the By Dept. (Schedule by Department) interface. Configure the shift, the start date, the end date and the holiday. Save the parameters to confirm configuration.
Schedule Shift by Individual: Select New Individual Shift in the By Indiv. (Schedule by Individual) interface. Select a person to schedule in the New Individual Shift interface. Configure the shift, the schedule start date and the end date. Save the parameters to confirm editing.
Attendance Report: Plug the USB flash drive in the device. In the Report interface, select a table type to export. Press the OK key to export the attendance report to the USB flash drive. The available USB flash drive format is FAT32.
The device will automatically check the USB flash drive memory. If there is no enough space for exporting, a prompt will be displayed. You are able to configure the record over threshold prompt and record delete function in the System interface.
Record over Threshold Pop up Prompt (%): If the attendance record memory reaches the configured value, the system will pop up a prompt to remind you. If configure the threshold to 99%, the system will pop up a prompt to remind you to delete the attendance data when the capacity reaches
the threshold. The available value: 1 to 99.
Record Delete: When the function is enabled, the terminal will delete the first 3000 attendance records when the memory is full, in order to save the new attendance records. By default, the function is enabled. See Section 5.2 Attendance Record Delete Rule in the User Manual of Fingerprint Time
Attendance Terminal.
View License: You can view the device License via the website: http://opensource.hikvision.com/Home/List?id=46
Regulatory Information
FCC Information
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user's authority to operate
the equipment.
FCC compliance: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
Device Activation
Activation Password (8 to 16 Characters)
OK Next
Input Method
[Number]
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the RE Directive 2014/53/EU, the EMC Directive
2014/30/EU, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot
be disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the
purchase of equivalent new equipment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info
Activating via SADP
1. Download SADP Software
Get the SADP software from the supplied disk. Install and run
the software.
2. Activate Device
Check the inactive device from the device list. Create a
password in the right side of the interface and confirm the
password.
3. Edit Device IP Address
Check the device and manually edit the device IP address, Port
No., Subnet Mask, Gateway, etc.
2006/66/EC (battery directive): This product contains a battery that
Industry Canada ICES-003 Compliance
cannot be disposed of as unsorted municipal waste in the
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
European Union. See the product documentation for specific
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
battery information. The battery is marked with this symbol, which
conditions:
may include lettering to indicate cadmium (Cd), lead (Pb), or
(1) this device may not cause interference, and
mercury (Hg). For proper recycling, return the battery to your
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
supplier or to a designated collection point. For more information
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploita-
see: www.recyclethis.info
tion est autorisée aux deux conditions suivantes :
Use only power supplies listed in the user instructions:
(1) l'appareil ne doit pas produire de brouillage, et
Model
Manufacturer
Standard
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
DSA-12PFT-12FUK 120100
Dee Van Enterprise Co., Ltd.
BS
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or
lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the
DSA-12PFT-12FAU 120100
Dee Van Enterprise Co., Ltd.
AS
antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
DSA-12PFT-12FIN 120100
Dee Van Enterprise Co., Ltd.
IS
necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
DSA-12PFT-12FUS 120100
Dee Van Enterprise Co., Ltd.
IEC
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type
DSA-12PFT-12 FBZ 120100
Dee Van Enterprise Co., Ltd.
NBR
Activating via Client Software
1. Get the client software from the official website. Install and run the client software.
2. Enter the Device Management page.
3. Click Device tab on the top of the right panel.
4. Click Online Device to show the online device area at the bottom of the page.
The searched online devices are displayed in the list.
5. Check the device status (shown on Security Level column) and select an inactive device.
6. Click Activate to open the Activation dialog.
7. Create a password in the password field, and confirm the password.
8. Click OK to activate the device.
9. Select an activated device in Online Device area, click
on the Operation column to open the Modify
Network Parameter window. Change the device IP address to the same subnet with your computer if you need
to add the device to the client.
Scan the QR code to get the user
manual for detailed information.
Note that mobile data charges
may apply if Wi-Fi is unavailable.

Advertisement

loading