Air Compressor Unit Usage Instruction - Sharp SVX500 Maintenance Manual

Table of Contents

Advertisement

PRECISION MACHINE TOOLS

3-2 Air Compressor Unit Usage Instruction

1) The pressure source of this machine's pressure pipeline goes through the air pressure preparation
unit, and the pressure is set to 6kg/cm
duration lasts more than 2 – 3 sec, NC will turn on the alarm, and CRT will display 1011 AIR
PRESSURE LOW. In this case, check the pressure source and then press the RESET button to
continue the operation.
2) Maximum pressure: 10kgf/cm²
3) Adjustment range: 0.5 ~8.7 Kg f/ cm²
4 ) Filter size:5μ
5 ) Recommended lube oil:ISO VG32
6) The pressure source should not be lower than: 5.5kgf/cm²
7) Although the air compressor preparation unit of the water filter has an automatically water drainage,
the machine operator should check whether there is any water accumulation at the shift or at the end of
the day. If the water drainage function is abnormal, water vapor may get into the air compressor
component, thereby reducing the lifespan. For the water drainage function of the filter to be more
effective, water in the air tank of the air compressor should fully drained out. It is also recommended to
install a dehumidifier at the pressure source to make sure that the air is dry.
8) The machine operator should pay attention to whether the pressure pipeline is making a bz kind of
noise. This may be due to gas leakage at the connector. Check the machine by tracing the noise. The
pipeline of this machine is connected by connectors, and the disassembling method is described below:
The nylon tube can be directly inserted into the connector. Use the finger or a flat screw driver to
secure the connector when pulling out the nylon tube.
 
 
2
. When the pressure source is less than 5kg/cm
Use a screwdriver or fingers to press down the fixing ring.
Fixing ring
tube
28
Maintenance Manual
2
, and the
 

Advertisement

Table of Contents
loading

Table of Contents