Download Print this page

Sealey GSA26 Instructions page 2

Air cut-off tool 75mm straight

Advertisement

2.
introDuction & sPecifications
Generation series air cut-off tools. Contoured handle insulates user from chill and vibration effects. Unlike
conventional cut-off tools, the cutting disc is in line with the handle for easier directional control. Metal disc guard
and rear exhaust can be rotated 360° giving operator added protection. Includes four-position air valve and
safety release trigger control to prevent accidental operation. Cutting disc not included.
Model no: . . . . . . . . . . . . . . . . . . . . Gsa26
Disc size:. . . . . . . . . . . . . . . . . . . . . Ø75 x 2 x 10mm
free speed: . . . . . . . . . . . . . . . . . . . 20000rpm
air consumption: . . . . . . . . . . . . . . 4cfm
operating Pressure: . . . . . . . . . . . . 90psi
air inlet size:. . . . . . . . . . . . . . . . . . 1/4"BsP
Weight: . . . . . . . . . . . . . . . . . . . . . . 0.5kg
cutting Disc: . . . . . . . . . . . . . . . . . . (single) Ptc/3c
noise Power:. . . . . . . . . . . . . . . . . . 96.7dB(a)
noise Pressure: . . . . . . . . . . . . . . . 85.7dB(a)
Measured Vibration: . . . . . . . . . . . . 2.2m/s²
uncertainty Value: . . . . . . . . . . . . . 0.005m/s²
3.
PreParinG tooL for use
3.1
air supply
recommended hook-up procedure is shown in fig 1.
3.1.1 Ensure tool air valve (or trigger) is in "off" position before connecting to the air supply.
3.1.2 You will require an air pressure of 90psi, and an air flow according to specification.
3.1.3  WarninG! Ensure the air supply is clean and does not exceed 90psi while operating the tool. Too
high an air pressure and unclean air will shorten the product life due to excessive wear, and may be
dangerous causing damage and/or personal injury.
3.1.4 Drain the compressor's air tank daily. Water in the air line will damage the tool.
3.1.5 Clean the compressor's air inlet filter weekly.
3.1.6 Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The
minimum hose diameter should be 1/4" I.D. and fittings must have the same inside dimensions.
3.1.7 Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all
connections are secure.
3.2
couplings.
Vibration may cause failure if a quick change coupling is connected directly to the tool.
To overcome this, connect a leader hose to the tool. A quick change coupling may then be used to
connect the leader hose to the air line recoil hose. See fig 1 & 2.
fig 1
© Jack Sealey Limited
(Pack of 5) Ptc/3c5
Original Language Version
fig 2
GSA26
Issue: 1 - 23/04/13

Advertisement

loading