Advertisement

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just
a little preventative care on your part can save you a great deal of time and money over the life of
your air conditioner. Before operating this product, please read the instructions carefully and save this
manual for future use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAC-C-12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pump House PAC-C-12

  • Page 1 Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. Before operating this product, please read the instructions carefully and save this manual for future use.
  • Page 2: Table Of Contents

    CONTENTS SOCIABLE REMARK Sociable remark..........................2 SAFETY PRECAUTIONS Safety rules ............................3 Operating condition ...........................3 Electrical information .........................4 IDENTIFICATION OF PARTS Accessories ............................4 Names of parts...........................5 AIR CONDITIONER FEATURES Electronic control operating instructions ...................6 OPERATING INSTRUCTIONS Operating instructions ........................7 INSTALLATION INSTRUCTIONS Location ............................9 Window kit installation ........................9 Exhaust hose installation ........................12 Water drainage ..........................13...
  • Page 3: Sociable Remark

    SOCIABLE REMARK When using this air conditioner in the European countries, the following informa- tion must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • Page 4: Safety Precautions Safety Rules

    SAFETY PRECAUTIONS Safety r ules To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Always do this Never do this Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
  • Page 5: Electrical Information

    IDENTIFICATION OF PARTS For your safety WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
  • Page 6: Names Of Parts

    IDENTIFICATION OF PARTS NAMES OF PARTS Front Operation panel Horizontal louver blade (swing automatically) Caster Carrying handle (both sides) Fig. 1 Rear Upper air filter (Behind the grille) Upper air intake Air outlet Dra in outlet (only for Pump hea ting model) Po wer cord outlet Po wer cord buckle (Used only when storing the un it)
  • Page 7: Air Conditioner Features

    AIR CONDITIONER FEATURES ELECTRONIC CONTROL OPE RATING INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel and remote controller and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel alone or with the remote controller . NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>>...
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS Error codes and protection code: Press the "MODE" button until the "DRY" Room temperature sensor error- indicator light comes on. Unplug the unit and plug it back in. Under this mode, you cannot select a fan If error repeats, call for service. speed or adjust the temperature.
  • Page 9 OPERATING INSTRUCTIONS SLEEP/ECO operation - Turning the unit ON or OFF at any Press this button, the selected temperature will time or adjusting the timer setting C/2 F increase(cooling) or decrease(heating) by 1 to 0.0 will cancel the Auto Start/ 30 minutes.The temperature will then increase Stop timer program.
  • Page 10: Installation Instructions

    INSTALLATION INSTRUCTIONS(optional) INSTALLATION INSTRUCTIONS Location The air conditioner should be placed on a firm foundation to minimize noise and virbration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces.
  • Page 11 INSTALLATION INSTRUCTIONS(optional) Installation in a double-hung sash window Foam seal A (adhesive type) 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window stool. Fig.8 2. Attach the window slider kit to the window stool. Adjust the Fi g.8 length of the window slider kit according to the width of window, shorten the adjustable window kit if the width of...
  • Page 12 INSTALLATION INSTRUCTIONS(optional) Installation in a sliding sash window 1. Cut the foam seal(adhesive type) to the proper length and Foam seal A (adhesive type) attach it to the window frame. See Fig.12. 2. Attach the window slider kit to the window stool. Adjust the length of the window slider kit according to the width of window, shorten the adjustable window kit if the width of Fig.12...
  • Page 13: Exhaust Hose Installation

    INSTALLATION INSTRUCTIONS Exhaust hose installation: The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. COOL,HEAT(heat pump type) or AUTO Install Fig.16a mode Fig.16b FAN,DEHUMIDIIFY or HEAT(electrical heat type) Remove mode Hole seat Hook 1.
  • Page 14: Water Drainage

    INSTALLATION INSTRUCTIONS Water drainage: During dehumidifying modes, remove the upper Continuous drain hose drain plug from the back of the unit, install the drain connector(5/8 universal female mender) with 3 4 hose(locally purchased). For the models √ without drain connector, just attach the drain hose to the hole.
  • Page 15: Care And Maintenance

    CARE AND MAINTENANCE CARE AND MAINTENANCE U pper filter (take out) IMPORTANT: 1) Be sure to unplug the unit before cleaning or servicing. Remove the 2) Do not use gasoline, thinner or other chemicals to clean screw ,then take the lower the unit.
  • Page 16: Troubleshooting Tips

    TROUBLESHOOTING TIPS TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1. Unit does not - P1 appears in the display window Drain the water in the bottom tray. Start when Pressing on/off - Room temperature is lower than Reset the temperature. Button the set temperature.(Cooling mode) - The windows or doors in the room...
  • Page 17 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. CP012IU-PD 202000192559 20130105...