Nautilus HYDRO-FORCE MX200M Operating Manual page 25

Table of Contents

Advertisement

Problem
Cause
Dual Circuit
Cords on the same circuit
Indicator
No voltage from one/ both outlets
Not Lighted
Light Bad
Dual Circuit Indicator Bad
One/Both Outlets Wired wrong
Pump-out
Building circuit breaker tripped.
not working
Faulty power cord
Faulty switches or internal wiring
Pump-out pump faulty
Pump-out filter clogged
Discharge hose restricted
Pump-out pump clogged
Vacuum
Building circuit breaker tripped.
Motor
Faulty power cord
not running
Faulty switches or internal wiring
Vacuum motor faulty
Loss of
Vacuum motor faulty
Vacuum
Vacuum motor gasket damaged
Recovery tank lid gasket damaged
Drain valve open
Drain valve leaking
Vacuum motor hoses loose /
leaking
Vacuum Valve in wrong Position
Vacuums not connected properly
Vacuum hose or tool clogged
Vacuum hoses or cuffs leaking
Recovery tank full
Float shutoff filter clogged
Float stuck in float shutoff
Pump-out Pump faulty
Recovery tank damaged
Chemical not
Solution tank not filling
feeding
Chemical hose restricted
Filter screen plugged
Low Incoming Water Pressure
Wrong size metering tip
Chemical proportioner faulty
Check valve in filter faulty
*
performed by experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
Solution
Move one cord to outlet on different circuit
Check circuit breakers – Reset breakers or move cords
Replace Light
Replace indicator
If hot & neutral sides switched on outlet, machine will work,
but light will not turn ON.
Reset breakers or move cords to other outlets
Replace cord (1696-6412)
Check wiring & test switch - Repair as needed *
Replace pump-out pump
Clean pump-out filter - Keep recovery tank clean –
Use Hydro-Filter
Un-kink, clean out or replace hose
Remove and clean out pump
Reset breakers or move cords to other outlets
Replace cord (1696-6412)
Check wiring & test switches - Repair as needed *
Replace vacuum motor (see model)
Replace vacuum motor (see model)
Replace gasket
Replace gasket
Close valve
Repair or replace drain valve
Reconnect or replace vacuum motor hoses
Check Vacuum Gate Valve Position. – PAGE 8
See vacuum connection instructions – PAGE 8
Clean out vacuum hoses and tool
Replace vacuum hoses, cuffs & connectors as needed
Drain tank
Clean float shutoff filter
Repair or replace float shutoff
Repair or replace pump out pump
Replace recovery tank
Check & repair auto fill assembly
Un-kink, shorten, clean out or replace hose
Clean or replace filter
Move bottle & shorten chemical hose to improve draw –
Find other water source.
Change metering tip
Replace chemical proportioner
Replace filter
: To reduce the risk of fire electrical shock or injury repairs to wiring should only be
25

Advertisement

Table of Contents
loading

Table of Contents