Nolafire NF30GID Owner's Manual

Gas insert - glass burner w/ ipi

Advertisement

Quick Links

NF30GI / NF30GID
G A S I N S E R T - G L A S S B U R N E R w / I P I
OWNER'S MANUAL
WARNING:
If the information in this manual is not followed exactly,
a fire or explosion may result causing property damage, personal
injury or loss of life. Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Report # 0268GN023S
CERTIFIED TO/ CERTIFIÉ AUX: ANSI Z21.88 / CSA2.33 VENTED GAS FIREPLACE HEATERS
NF-003

Advertisement

Table of Contents
loading

Summary of Contents for Nolafire NF30GID

  • Page 1 NF30GI / NF30GID G A S I N S E R T - G L A S S B U R N E R w / I P I OWNER’S MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Safety Precautions

    Safety Precautions WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS •...
  • Page 3 NEVER ALLOW CHILDREN shut. TO TOUCH GLASS. • If the NF30GI / NF30GID unit is pulled out of its installation, A barrier designed to reduce the risk of burns from the and the vent-air intake system is disconnected for any reason,...
  • Page 4: Table Of Contents

    Table of Contents Safety Precautions......................2 Table of Contents......................4 Codes And Approvals.......................5 Specifications........................6 Rating Label Location...................6 Dimensions......................6 Install Depth......................6 Options Dimensions....................7 Operating Instructions....................8 Lighting and Turning Off Instructions..............8 Venturi Adjustment....................9 Normal Sounds During Operation.................9 Remote Control Operations..................9 System Description.....................10 Technical Data....................10 Transmitter....................10 Battery Holder.....................11 Operating Procedure...................12...
  • Page 5: Codes And Approvals

    After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local NolaFire dealer. See “D ”...
  • Page 6: Specifications

    16.27 19.85 16.70 2.52 3.26 1.45 17.79 Figure 1: NF30GI / NF30GID Exterior Dimensions. nstaLL epth The install depth will vary depending on what surround panel is used. Table 1 shows the required depth for each surround panel. Surround Panel...
  • Page 7: Options Dimensions

    Specifications nF30gi / nF30giD o ptions imensions 18” ” 25 ” ” 38” Figure 2: NF30GI / NF30GID Modern Surround. Table 2: NF30GI / NF30GID Options Dimensions. Modern Surround (NF-001) Height 25” (635mm) Width 38” (965 mm)
  • Page 8: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING WARNING:...
  • Page 9: Venturi Adjustment

    The Proflame 2 GTMFLSA is a modular remote control system that directs the functions of the NF30GI / NF30GID. The Proflame 2 GTMFLSA is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the appliance.
  • Page 10: System Description

    Operating Instructions For NF30GID models refer to the separate Dexen user manual supplied for remote control operations. ystem escRiption The Proflame 2 Remote Control System consists of two (2) elements: 1. Proflame 2 Transmitter. 2. Integrated Fireplace Controller (IFC) and wiring harness to connect to the gas valve, stepper motor battery holder, and convection fan.
  • Page 11: Battery Holder

    Operating Instructions Key Lock Transmission Low battery alarm Thermostat OFF/ Room ON/SMART Temperature CPI mode Set Point Aux ON Temperature/Level/State ot used Flame ON Split Flow ot used Dimmer ON Comfort fan ot used Figure 6: Proflame 2 Transmitter LCD Screen. atteRy oLDeR The Battery Holder (Figure 7) connects directly to the IFC with a wiring harness.
  • Page 12: Operating Procedure

    Operating Instructions peRating RoceDuRe Initializing The System For The First Time Install the four (4) AA batteries into the IFC battery holder. Note the polarity of the battery and insert into the battery bay as indicated on the body of the battery holder. Press and release the reset button (see Figure 7). The IFC will “beep”...
  • Page 13 Operating Instructions Remote Flame Control The Proflame 2 GTMF has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off. The Up Arrow Key will increase the flame height each time it is pressed.
  • Page 14 Operating Instructions Split Flow Control This function is not used on the NF30GI and can be disregarded. Figure 14: Split Flow Control Aux Control This function is not used on the NF30GI and can be disregarded. Figure 15: Aux Control Key lock This function will lock the keys to avoid unsupervised operation.
  • Page 15 Operating Instructions Low Battery Power Detection Transmitter: The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (see Figure 17) before all battery power is lost.
  • Page 16: Maintenance And Service

    Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury. At least once a year, run through the following procedures to ensure the system is clean and working properly.
  • Page 17: Cleaning The Firebox

    The glass must be purchased from an NolaFire dealer. No substitute materials are allowed. Remove the door (see page 16). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
  • Page 18: Fuel Conversion

    Maintenance And Service onVeRsion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 19 Maintenance And Service 7. Convert the SIT gas valve: a) Use a T-20 driver to remove the two screws that hold the servo regulator to the gas valve and disconnect the wire harness from the IFC. b) Remove the rubber regulator diaphragm that is situated between the servo regulator and the valve body.
  • Page 20: Initial Installation

    The NolaFire NF30GI / NF30GID may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Before starting, refer to please reference the information in Table 5 and Figures 27 and 28.
  • Page 21: Venting

    The vent length for the NF30GI / NF30GID must be between 8ft (2.44 m) and 30ft (9.14 m). This model is vented with a 3” intake and a 3” exhaust aluminum or stainless steel flex vent leading into a vertical termination cap.
  • Page 22 Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed. NOTE: If the NF30GI / NF30GID unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant and reconnected with three (3) sheet metal screws evenly spaced.
  • Page 23: Baffle Plate Adjustment

    It must be completely sealed. *This installation is not tested and is not covered by the certification of this appliance. Please contact authorities having jurisdiction in your area for restrictions* Figure 28: Alternate Installation of NF30GI / NF30GID aFFLe Late...
  • Page 24: Installing The Unit

    4. Check that the chimney clean outs fit properly. The flue damper must be fully blocked open or removed for installation of the NF30GI / NF30GID; the smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
  • Page 25 Initial Installation QUALIFIED INSTALLERS ONLY 5. Stretch the Ø3” (76mm) flex vent liners to the length needed to ensure they can be easily connected to the vent terminals. M&G 6. Install the flex pipe assembly up through the chimney, DirectVent ensure that the pipe slides through far enough to connect EXCELDirect onto the vent cap.
  • Page 26: Zero Clearance Fireplace Installation

    Initial Installation QUALIFIED INSTALLERS ONLY 14. As you push the unit into its final position in the fireplace, if the vent collar plate was removed, reinstall it on the stove by pulling it into the brackets on top and reinstall the two Torx T-20 screws.
  • Page 27: Electrical Requirements

    18 AWG wire with a temperature rating of at least 105°C. Note: For NF30GID specific wiring diagram refer to the Dexen user manual supplied and label attached to the fireplace.
  • Page 28: Gas Line Connection

    ½ psig (3.45 KPa) or the valve will be damaged. Figure 37: ⅜” NPT Male Pipe Nipple with Cover Removed. Table 7: Orifice and Pressure Information. NF30GI / NF30GID with Glass Burner Main Burner Natural Gas Propane Gas Orifice:...
  • Page 29: Adjusting The Pilot Flame

    Pilot Pilot Inlet Adjustment Solenoid Pressure Screw Figure 38: Valve Details. See Dexen User Manual for NF30GID valve details NEVER USE AN OPEN FLAME FOR LEAK TESTING. nF30giD Djusting iLot Lame Does not appLy to moDeLs The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted.
  • Page 30: Secondary Installation

    Secondary Installation aFety cReen nstaLLation emoVaL To install the safety screen hold it upright in front of the fireplace with four (4) hooks pointing towards the fireplace. Slide the hooks into the corresponding brackets on each side of the cabinet (see figures 40 and 41).
  • Page 31: Surround Panel Installation

    Secondary Installation uRRounD aneL nstaLLation WARNING: The surround becomes hot when the unit is operating; ensure that the unit is turned off, and that it has cooled to room temperature before beginning this installation. Height Width Modern 25” (635 mm) 38”...
  • Page 32: Firebox Liner And Burner Tray Removal / Installation

    WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 1. Ensure the NF30GI / NF30GID is turned off and allow the unit to cool.
  • Page 33: Glass Media Installation

    Secondary Installation Lass eDia nstaLLation Pour the glass media into the tray and evenly distribute over the entire tray (see figure 48). Make sure the burner starter tube is un-obstructed for a clear path to the pilot flame and keep the pilot area clear of any glass media (see figure 49).
  • Page 34: Troubleshooting

    Troubleshooting nF30giD iagnostic Lash oDes Does not appLy to moDeLs 1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in intervals until the system is reset.
  • Page 35 Troubleshooting Note: For NF30GID specific troubleshooting refer to the Dexen user manual supplied Problem Possible Cause Solution The pilot flame has gone out · Turn it ON Thermostat The On/Off switch is turn to OFF does not work The thermostat is set too high ·...
  • Page 36 Troubleshooting Problem Possible Cause Solution · Turn the system off by pressing the ON/OFF button on the transmitter · After approximately 2 seconds press the ON/OFF button on the transmitter again. · In the manual flame control mode, use the down arrow button to reduce the flame to off, indicated by the word OFF displayed on the transmitter LCD screen.
  • Page 37: Parts List

    Parts List Note: For NF30GID specific replacement parts refer to the Dexen user manual supplied Reference Part Description Part Number Number DV Flue Adaptor Bottom Gasket 50-2497 NF30GI / NF30GID Owner’s Manual NF-003 LP Conversion Stepper Motor 50-3753 Conversion Kit LP to NG...
  • Page 38: Parts Diagram - Components

    Parts Diagram - Components...
  • Page 39: Warranty

    Warranty for Gas Products Sherwood Industries Ltd. (“Sherwood”) hereby warrants, subject to the terms and Exclusions conditions herein set forth, this product against defects in material and workmanship This warranty does not cover: during the specified warranty period starting from the date of original purchase at retail. ƒ...
  • Page 40: Installation Data Sheet

    Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: NAME OF DEALER: _________________________________________ _________________________________________ ADDRESS: ADDRESS: _________________________________________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ PHONE:___________________________________ MODEL:___________________________________ NAME OF INSTALLER: SERIAL NUMBER:___________________________ _________________________________________ DATE OF PURCHASE: _____________...

This manual is also suitable for:

Nf30gi

Table of Contents