5 Monitoring during operation / 5.1 Oil pressure, oil temperature
Status for operation
Not admissible → do not start engine (before start: preheat
oil)
Table 8: Lubricating oil temperature at the inlet
Lubricating oil temperature at the outlet
The oil temperature at the outlet is mainly dependant on:
¡
Lubricating oil temperature and pressure at the oil inlet
¡
Engine load and turbocharger speed
¡
Exhaust gas temperature
The maximum admissible oil temperature at the outlet is listed in the following table. The
specified oil outlet temperature is to be considered as alarm value for the turbocharger op-
eration and must be monitored according to the current regulations.
Fig. 11: Oil temperature at the outlet
Status for operation
Admissible
Admissible
Temporarily admissible → alarm
Temporarily admissible → alarm
Not admissible → stop engine
Not admissible → stop engine
Table 9: Lubricating oil temperature at the outlet
If the turbocharger has been operated for a longer period of time outside the admissible
range, ABB Turbocharging recommends having the turbocharger inspected by an ABB Tur-
bocharging Service Station.
© Copyright 2021 ABB. All rights reserved.
Oil temperature at the inlet
T
[°C]
oil,inlet
45
80
45
80
45
80
HZTL4034_EN
Oil temperature at the inlet
T
[°C]
oil,inlet
< 30
Oil temperature at the outlet
T
[°C]
oil,outlet
≤ 110
≤ 125
> 110
> 125
> 120
> 135