Summary of Contents for DAVID SLS-1

  • Page 1 DAVID Vision Systems GmbH DAVID Vision Systems GmbH DAVID Vision Systems GmbH Rudolf-Diesel-Str. 2a D-56070 Koblenz Germany Phone: +49(0)261 983 497-70 Fax: +49(0)261 983 497-77 Mail: service@david-vision-systems.de Web: www.david-laserscanner.com © 2012 © 2012 DAVID Vision Systems GmbH © 2012 © 2012...
  • Page 2 3DPE.ir Specifications scan object size ~ 10mm - 600mm now upgraded to DAVID-CAM-3-M 1280 x 960 camera with (double the resolution) new upgraded megapixel camera lens from Computar resolution: ~0.1% of object size (down to 0.04mm) precision: ~0.1% of object size (down to 0.1mm)
  • Page 3: Safety Instructions

    • Mounting rack with ball joint (for camera) • Tripod with protective bag • 2 calibration panels with 2 mounting tracks 90° • USB drive with DAVID-Laserscanner Pro Edition and camera drivers • Accessories for projector • External wall power supply •...
  • Page 4 The camera can be mounted left or right of the projector – depending on how a suitable distance between their lenses can be achieved. The DAVID software also supports a vertical setup, with camera and projector above each other.
  • Page 5: Installation

    Installation Installation Installation Installation Connect all components as depicted below: VGA / HDMI Installation of the Camera Drivers Installation of the Camera Drivers Installation Installation of the Camera Drivers of the Camera Drivers 1. Plug the USB drive into your PC, then choose “Open” resp. “Explorer”. 2.
  • Page 6 The Windows Taskbar and most desktop icons will be shown only on the monitor. All windows can be moved from monitor to projector, and vice versa. If the DAVID main window is shown on your projector, grab its title bar with the mouse and move it over to your monitor.
  • Page 7 Calibration of the Scanner Calibration of the Scanner One advantage of the SLS-1's modular setup is that its size can be adjusted to very different object sizes. Therefore, calibration (measurement of the current hardware setup in the DAVID software) is required, allowing the software to obtain undistorted 3D data at the correct scale.
  • Page 8 6. Aim the camera so that it can see the projected pattern on the object. Then fix the ball joint. 7. The Exposure Time should be set to 1/60s, otherwise the camera image might flicker or pulse when looking at the projection. 8.
  • Page 9 The camera image must show at least the 6 ring markers and a few dot markers. The whole camera image should be filled with around 15 to 70 calibration markers, and the camera should not able to look past the calibration boards. You can move, rotate and tilt the scanner as a whole, but you should not change anything above the red mounting rack.
  • Page 10 You may move, rotate and tilt the scanner as a whole, and you can close and restart the DAVID software, without losing the calibration. However, if you rotate camera or projector with respect to each other or change the focus (e.g. in order to...
  • Page 11 • Each click on “Start” performs a new scan. DAVID projects a set of different stripe patterns and records the images. This takes 2-4 seconds, depending on the settings.
  • Page 12 • If you check the “Auto. grab texture” option, DAVID will record a texture with each scan. If the texture is too bright or too dark, you can adjust the texture settings in the Texturing menu (see below). • With your mouse, you can rotate, move and zoom the 3D view.
  • Page 13 • DAVID offers several alignment modes. In general you should start with the “Free” mode, which aligns one scan to one other with each step. In order for the automatic mode to find the correct alignment, the scans have to overlap sufficiently, i.e.
  • Page 14 • Hint: All scan movements can be undone separately with the “Undo” button • Hint: You can save your single scans at any time. They will be saved in their current position and rotation in space, so you won't have to align them again. •...
  • Page 15: Terms Of Warranty

    DAVID Laserscanner® after-sales service for repair. Repairs made after expiry of warranty will be subject to a charge. Your statutory rights are not affected through this warranty.