1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 Temperature and humidity controller for seasoning-maturing cabinets XLH360 XLH360 XLH360 XLH360 C C C C M M M M Operating Instructions 1592017410 XLH360 GB r1.0 15.04.2005.doc...
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 C C C C M M M M XLH360 XLH3 XLH3 XLH3 INDICE 1. GENERAL WARNING __________________________________________________________ 3 2. GENERAL DESCRIPTION ______________________________________________________ 3 3. TEMPERATURE REGULATION __________________________________________________ 3 4.
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 1. GENERAL WARNING PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference.
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 4.2 DEHUMIDIFYING ACTION WITHOUT DEHUMIDIFIER RELAY, OA1 DIFFERENT FROM DEH In this case the dehumidifying action is performed by setting the following parameters in this way:...
Page 5
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 The diagrams displays a typical maturing cycle with the starting dripping phase. DRIPPING PHASE lasts for the “dri” time, without humidity control, temperature set is SETG RUNNING PHASE lasts for the “on”...
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 8. THE DISPLAY To display and modify target temperature set point. (SET TEMP) for the running (St1)and the dripping (StG) phase. To display and modify target humidity set point (SET %RH) of the running (SH1) phase; in programming mode it selects a parameter or confirm an operation.
Page 7
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 MODE FUNCTION ° C FLASHING If measurement unit is °C, it flashing on programming mode ° F °F ° F FLASHING If measurement unit is °F, it flashing on programming mode...
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 NOTE: each parameter in “Pr2” can be removed or put into “Pr1” (user level) by pressing SET %RH + n n . When a parameter is present in “Pr1”...
Page 9
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 Defrost type: rE = electrical heater (Compressor OFF); in = hot gas (Compressor and defrost relays ON) Defrost mode: in = interval mode. The defrost starts when the time “Idf” is expired; Sd=Smartfrost mode. The IdF time (interval between defrosts) is increased only when the compressor is running (even non consecutively).
RS485 serial address for temperature loads (0÷247) identifies the instrument within a control or supervising system. RS485 serial address for humidity loads (0÷247) identifies the instrument within a control or supervising system. Parameter table: (read only) it shows the original code of the dIXEL parameter map. Software release: (read only) Software version of the microprocessor.
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 10.6 DIGITAL INPUTS POLARITY The digital input polarity depends on the “i1P” parameters. CL : the digital input is activated by closing the contact; OP : the digital input is activated by opening the contact 11.
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 11.2 PANEL MOUNTING Make a hole in the panel with dimensions described in Fig. 4 (simplified) or Fig. 5 (completed) Unscrew the 4 frontal screws (Fig. 1, A, B, F, G) and remove the cover (Fig. 1, C).
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 NOTE the message “Err” is displayed for failed programming. In this case turn the unit off and then on if you want to restart the download again or remove the “Hot key”...
1592017410 cod. 1592017410 Operating Instructions cod. cod. 1592017410 1592017410 16. XLH360 WIRING CONNECTIONS HOT KEY 20A 250V 35 36 16FLA(96 L RA ) 20A 250V 2 50V ~ 16 FLA (96L R A) 250V~ 250V~...